10.6 Remote control faults (cable operation)
Fault
Possible cause
Remedy
Engine stops for no
reason
Emergency stop switch actuated or
defective
Pull out the emergency stop switch
Have examined by a specialist; replace if
necessary
Fuse F54, F67 or F103 triggered
Check the fuses; replace if necessary
Have examined by a specialist
Operating mode toggle switch defective
Have examined by a specialist; replace if
necessary
Relay K11 defective
Have examined by a specialist; replace if
necessary
Cable defective
Check cable for tight fit
Have examined by a specialist; replace if
necessary
Remote control defective
Have examined by a specialist; replace if
necessary
Cross-slope sensor defective
Check the cross-slope sensor signal,
input code 1405
Have examined by a specialist; replace if
necessary
Control defective
Have examined by a specialist; replace if
necessary
Ignition key in posi-
tion "I", display
module operative,
but engine cannot
be started
The travel lever or steering lever is not in
neutral position
Disengage the travel lever or steering
lever and move to neutral position
Check the travel lever signal, input code
2500
Check the steering lever signal, input
code 2501
Fuse F119 triggered
Check the fuses; replace if necessary
Have examined by a specialist; replace if
necessary
Battery not charged or defective
Check the battery charge; recharge if
necessary
Replace defective battery
Cross-slope sensor defective
Check the cross-slope sensor signal,
input code 1405
Have examined by a specialist; replace if
necessary
Relay K39 defective
Check the relay control signal, input code
5070
Have examined by a specialist; replace if
necessary
Troubleshooting – Remote control faults (cable operation)
D.ONE
159
Summary of Contents for D.ONE
Page 2: ...2...
Page 7: ...1 Introduction Introduction D ONE 7...
Page 11: ...2 Technical data Technical data D ONE 11...
Page 16: ...Technical data Noise data D ONE 16...
Page 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Page 50: ...Concerning your safety Signage D ONE 50...
Page 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Page 60: ...Indicators and control elements Remote control D ONE 60...
Page 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Page 69: ...6 Operation Operation D ONE 69...
Page 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Page 101: ...8 Maintenance Maintenance D ONE 101...
Page 142: ...Maintenance As required D ONE 142...
Page 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Page 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Page 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Page 167: ...11 Disposal Disposal D ONE 167...
Page 169: ...12 Appendix Appendix D ONE 169...
Page 189: ......
Page 190: ......