GBK60027 DX-SLM Installation Manual Issue 5
wired together (single battery box), the best position for this circuit breaker is between
the two batteries. If the batteries are individually plugged together (separate battery
boxes), each battery requires a circuit breaker. Separate lighting and driving circuit
breakers are used, so that a fault, which causes a circuit breaker to operate, will not
disable both lighting and driving.
Note:
Battery negative has two connections to the SLM. This is to ensure that a
break in one battery connection will not disable driving or lights.
Battery Type
The DX System is designed to perform optimally with either Lead-Acid or Gel Cell
deep cycle batteries. Consult Dynamic Controls for other battery types. It is
recommended that two 12 V batteries with capacity greater than 20 A hours be
used.
5.4.5
SLM Connection to Lights
There are three lighting outputs: Pin 2 Side Lights -
Pin 3 Left Indicators -
Pin 4 Right Indicators -
The Side Light Output
This output is used to power head and taillights. Multiple bulbs can be connected to
the output in parallel, as shown in the following diagram. The output is active pull-
down when the light is turned on.
The Left and Right Indicator Outputs
These outputs are also active pull-down when the light is turned on. Again, multiple
bulbs can be connected to each output.
Power Source
Pin 5 is connected to Pin 16 internally. This allows the lights to be supplied with power
from Pin 5 or Pin 16.
Example of Lighting Wiring
Alternative Pin 5 Supply
Page 20
M
T