Dynalite MH2065v Instruction Manual Download Page 1

DYNALITE INC 

1050 Commerce Ave ● Union ● NJ ● 07083 

908-687-8800 Phone ● 908-686-6682 Fax 

www.dynalite.com 

Dynalite Lighting Controls and  

System Accessories 

 

Instruction Manual 

For Model MH2065v 

Fan Cooled Strobe Head 

Replacement of Modeling Lamp 

 

1.  Unplug the flash head 

from the power pack 
and allow the flash 
head to cool before 
touching the modeling 
lamp. 

2.  Remove flash head 

accessories if present. 

3.  Remove the flash tube from the head in or-

der to reach the modeling lamp. 

4.  Remove the modeling lamp by carefully 

griping it with a soft cloth and pulling 
straight out. 

5.  Install the new lamp by aligning the pins 

with the socket and press the lamp in place. 

 

Please note: 

Do not touch the new lamp with your hands. 

Oils from your hands can cause premature failure of the 
lamp or could cause an unexpected shattering of the lamp. 
 

Replacement of the Flash Tube 

1.  Unplug the flash head 

from the power pack 
and allow the flash head 
to cool before touching 
the flash tube. 

2.  Remove flash head ac-

cessories if present. 

3.  Remove the flash tube by rocking and or 

pulling the outer edge of the reflector as-
sembly out of the flash housing. 

4.  Install the new flash tube assembly by align-

ing the three connection pins with the three 
connection sockets inside the flash housing.  
Ensure that the connection pins are aligned 
correctly and in the proper configuration 
before installing the flash tube assembly.  
Gentle push the reflector/flash tube assem-
bly until the edge of the reflector is flush 
with the outer edge of the flash housing. 

 

Note: 

Use only the appropriate flash tube. 

RR-GH 

RR-4G 

RR-AFBD 

RR-AF 

RR-50 

RR-80 

RR-AR 

SR-65SN 

UCBW-36 
UBBW-44 

UQSS-48 

R-11/20/2013 