Dynacord PowerSub 312 Owner'S Manual Download Page 1

PowerSub 312

Powered 3-Channel Subwoofer

Owner‘s Manual | Bedienungsanleitung

Summary of Contents for PowerSub 312

Page 1: ...PowerSub 312 Powered 3 Channel Subwoofer Owner s Manual Bedienungsanleitung ...

Page 2: ... 7 POWER SCHALTER 7 NETZEINGANG 7 TECHNISCHE DATEN 16 ABMESSUNGEN 16 BLOCK DIAGRAM 17 AUFBAUBEISPIELE 18 CONTENTS IMPORTANT SAFETY INSTRUCTIONS 11 IMPORTANT SERVICE INSTRUCTIONS 11 DESCRIPTION 12 UNPACKING WARRANTY 12 QUICK START 13 CONTROLS 14 INPUT OUTPUT 14 LEVEL 15 POWER SWITCH 15 MAINS IN 15 SPECIFICATIONS 16 DIMENSIONS 16 BLOCK DIAGRAM 17 SETUP EXAMPLE 18 2 ...

Page 3: ...ervicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden führen Sie keine Wartungsarbeiten durch die nicht in der Bedienungsanleitung beschrieben sind außer Sie sind hierfür qualifiziert Überlassen Sie sämtliche Servicearbeiten und Reparaturen einem ausgebildeten Kundendiensttechniker 1 Bei Reparaturarbeiten im Gerät sind die Sicherheitsbestimmungen nach EN 60065 VDE 0860 einzuhalten ...

Page 4: ... Beschädigung Alle Bedienteile sind versenkt eingebaut wodurch die empfindlichen Teile des PowerSub 312 auch beim Transport optimal geschützt sind Zwei stabile Tragegriffe und ein eingebauter Schraubflansch für Hochständerstangen ermöglichen einen bequemen Transport und eine optimale platzsparende Aufstellung zum Publikum Auspacken und Garantie Öffnen Sie die Verpackung und entnehmen Sie den Power...

Page 5: ...en Sie den PowerSub 312 in Betrieb 5 Schliessen Sie nun ein Mikrofon an den 1 Eingangskanal Ihres Mischpultes z B CMS 1000 an Stellen Sie alle Drehregler in Mittelstellung Sprechen oder singen Sie laut in das Mikrofon und justieren den Gain Regler im Kanal so daß die grüne SIGnal LED aufleuchtet Die rote PeaK LED sollte nicht oder nur gelegentlich aufleuchten Die rote LED zeigt an daß im Kanal ber...

Page 6: ...und rechten Kanals werden dabei summiert und zur internen Endstufe weitergeleitet Für alle anderen Anwendungsfälle wird nur der L Mono Eingang verwendet Parallel Outputs L R Diese Buchsen dienen zum Weiterschleifen des Ein gangssignals und liegen direkt parallel zu den Eingangs buchsen CLIP zeigt beim Aufleuchten an daß der interne Leistungs verstärker aktuell im Grenzbereich der Aussteuerbarkeit ...

Page 7: ...r Ausgänge kann bis zu 250W Leistung an 4 Ohm liefern Es können also bis zu zwei 8 Ohm Boxen je Aus gang angeschlossen werden EXTERNAL SUB OUTPUT Hier kann zusätzlich ein passiver Subwoofer z B SUB 112 angeschlossen werden Die maximale Aus gangsleistung beträgt 400W an 8 Ohm POWER Schalter Netzschalter zum Ein und Ausschalten des Gerätes Der Netzschalter ist be leuchtet wenn der PowerSub 312 einge...

Page 8: ...8 ...

Page 9: ...Notes ...

Page 10: ...RUCTIONS 11 IMPORTANT SERVICE INSTRUCTIONS 11 DESCRIPTION 12 UNPACKING WARRANTY 12 QUICK START 13 CONTROLS 14 INPUT OUTPUT 14 LEVEL 15 POWER SWITCH 15 MAINS IN 15 SPECIFICATIONS 16 DIMENSIONS 16 BLOCK DIAGRAM 17 SETUP EXAMPLE 18 10 ...

Page 11: ...nel 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be operated and is connected to the mains 3 Switch off the power before retrofitting any extensions changing the mains voltage or the output voltage 4 The ...

Page 12: ...chanical damage All controls are recessed to provide optimum protection for the sensitive parts of the PowerSub 312 even during transportation Two stable carrying handles and an integrated threaded pole mount flange allow comfortable transportation and optimum space saving installation Unpacking and Warranty Open the packaging and carefully take out the PowerSub 312 Remove the protective foil from...

Page 13: ...ower up the PowerSub 312 5 Connect a microphone to input channel 1 of the mixer e g CMS 1000 Set all rotary controls to their center position While speaking or singing loud into the microphone adjust the channel s Gain control so that the green SIGnal LED lights The red PeaK LED should not light at all or blink only once in a while The red LED indicates that the audio signal is already distorted w...

Page 14: ...ls of both channels are summed prior to being processed in the power amplifier section All other applications employ only the L Mono input Parallel Outputs L R Connected in parallel to the input jacks these connectors are used for carrying through the input signal CLIP indicates when lit that the internal power amplifier is actually operated in the border range before clipping Short term blinking ...

Page 15: ...capacity of up to 250W into 4 ohms In other words up to two loudspeaker systems with 8 ohms impedance can be connected in parallel per output EXTERNAL SUB OUTPUT This output allows connecting an additional passive subwoofer e g SUB 112 Maximum output capacity is 400W into 8 ohms POWER switch Mains switch for switching the unit s power ON or OFF The mains switch lights after switching on the PowerS...

Page 16: ...plifier Sub 800 W 4 Ohms Power Amplifier MID HIGH 2 x 250 W 4 Ohms SPL1W 1m 92 dB Max SPL1m 121 dB Sub Transducer DND 12S400 Switchable X Over Frequencies 70 Hz 100 Hz 140 Hz DimensionsW x H x D 445 x 380 x 445 mm Weight 22 5 kg Shipping Weight 27 kg Warranty 36 months ...

Page 17: ...17 BLOCK DIAGRAM ...

Page 18: ...18 AUFBAUBEISPIELE SETUP EXAMPLE PowerSub 312 D 8 D 8 D 8 D 8 CMS 1000 PowerSub 312 Sub 112 CMS 1000 ...

Page 19: ...AUFBAUBEISPIELE SETUP EXAMPLE PowerSub 312 CMS 1000 D 8 D 8 D 8 D 8 19 ...

Page 20: ... with FCC EN 61000 3 2 2000 EN 61000 3 11 2000 EN 55103 1 1997 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequ...