Dyna-Glo BFSS10LPT-4P Manual Download Page 1

VENT-FREE

BLUE FLAME

GAS WALL HEATER

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

WARNING: 

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY 

DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

       WARNING:

 This appliance is equipped for 

(natural or propane) gas. Field conversion is not 

permitted.

- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or 

  any other appliance.
  WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.

  • Do not touch any electrical switch; do not use any phone in your building.

  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

     instructions.

  • If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the 

   gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided.

Refer to Air For Combustion and Ventilation section on page 8 of this manual.

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) 

home, where not prohibited by local codes.

 

This appliance is only for use with the type of gas indicated on the rating plate. 

This appliance is not convertible for use with other gases.

C           US

C           US

ANS Z21.11.2-2016

Gas Fired Room Heaters

Volume II - Unvented Room Heaters

IMBFSS4 - 2019-01-15

  MODEL #

Questions, problems, missing parts?

 Before returning to your retailer, call our customer 

service department at 1-877-447-4768,

 

8:30 a.m. –  4:30

 

p.m., CST, Monday – Friday or 

email us at [email protected].

Propane

BFSS10LPT-4P

BFSS20LPT-4P

BFSS30LPT-4P

Natural Gas

BFSS10NGT-4N

BFSS20NGT-4N

BFSS30NGT-4N

Summary of Contents for BFSS10LPT-4P

Page 1: ...ice must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate...

Page 2: ...0 20 000 MIN BTU 8 000 16 000 Fuel Type Propane Propane Ignition Electronic Push Button Electronic Push Button Manifold Pressure 10 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Mini...

Page 3: ...ect Models 120V 60Hz 18W 0 15A SERIES BFSS10NGT 4N BFSS20NGT 4N MAX BTU 10 000 20 000 MIN BTU 5 000 10 000 Fuel Type Natural Gas Natural Gas Ignition Electronic Push Button Electronic Push Button Mani...

Page 4: ...ance is intended for supplemental heating This appliance can be used with propane or natural gas It is shipped from the factory adjusted for use with propane CARBON MONOXIDE POISONING Early signs of c...

Page 5: ...6 Do not run heater Where flammable liquids or vapors are used or stored Under dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater and pilot off If heat...

Page 6: ...State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heater...

Page 7: ...proximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplement...

Page 8: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are...

Page 9: ...U hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct v...

Page 10: ...directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for require...

Page 11: ...unted on the wall or on the floor using the support legs Select Models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining w...

Page 12: ...connected from gas supply and removed from wall before installing fan accessory Contact a qualified service person to do this 2 Remove fan knock out panel using a screwdriver See Fig 9 Attach Fan to t...

Page 13: ...e table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table e...

Page 14: ...wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wood screws ST 8 45 16...

Page 15: ...th expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is fi...

Page 16: ...line pressure is higher the unit will not work and heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied In...

Page 17: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Page 18: ...light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you c...

Page 19: ...eep control depressed for 30 seconds after pilot lights Release control knob Note If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries...

Page 20: ...ERATION INSPECTING BURNERS Check pilot flame pattern daily when in use and at least yearly by a qualified service agency PILOT FLAME PATTERN Fig 26 shows a correct pilot flame pattern Fig 27 shows an...

Page 21: ...etc Additionally an excess amount of Mercaptane in the fuel can result in an orange or yellow colored flame The upper third of flame may be bright yellow when operated on propane When this heater is s...

Page 22: ...air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you coul...

Page 23: ...de is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor or ignition mod ule 7...

Page 24: ...tomer service 4 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance p...

Page 25: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 23 2 Control valve is defective 1 Locate...

Page 26: ...dels 1 There is no power to the fan 2 Fan is set to AUTO 3 Fan motor is bad 1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is no...

Page 27: ...9 LP L 950 N A BF30K 39 LP L 950 N A 3 2 ODS NG Natural Gas Pilot 1 N A BF30K 39 NG L 950 N A BF30K 39 NG L 950 N A BF30K 39 NG L 950 4 Ignition Wire 1 BF30K 38 L 1050 BF30K 38 L 1050 BF30K 38 L 1050...

Page 28: ...27...

Page 29: ...______________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please Take...

Page 30: ...ds SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 828...

Page 31: ...tor accionado por gas no ventilado Utiliza aire ox geno de la habitaci n en la cual est instalado Deben tomarse medidas para una combusti n y aire de ventilaci n adecuados Consulte la secci n Aire par...

Page 32: ...n del distribuidor 10 pulg de columna de agua 10 pulg de columna de agua Presi n de gas de entrada M ximo 14 pulg de columna de agua 14 pulg de columna de agua M nimo Para fines de ajuste de entrada...

Page 33: ...de columna de agua 14 pulg de columna de agua M nimo Para fines de ajuste de entrada 6 pulg de columna de agua 6 pulg de columna de agua Dimensiones pulg Alto x Ancho x Di metro La altura incluye las...

Page 34: ...evisto para calefacci n complementaria Este aparato puede ser usado con propano o gas natural Es enviado de la f brica ajustado para ser usado con propano PELIGRO DE ENVENENAMIENTO CON MON XIDO DE CAR...

Page 35: ...o 6 No haga funcionar el calefactor Donde se almacenen o usen l quidos o vapores inflamables Bajo condiciones de mucho polvo 7 Antes de usar pulidor de mueble cera limpiador de alfombra o productos si...

Page 36: ...funcionamiento del calentador Estado de Massachusetts La instalaci n debe ser hecha por un fontanero o t cnico de gas calificado en la Commonwealth de Massachusetts Los vendedores de calefactores com...

Page 37: ...aproximadamente 1 onza 30 mL de agua por cada 1 000 BTUs 0 3 Kw de entrada de gas por hora Un calefactor no ventilado de habitaci n est previsto como un calefactor comple mentario en lugar de una fuen...

Page 38: ...on puertas son consideradas una parte del espacio no confinado Este calefactor no deber ser instalado en un espacio confinado o construcci n inusualmente herm tica a menos que se tomen medidas para un...

Page 39: ...Ejemplo Le os de calentador a gas __________BTU hr Calentador de agua a gas 30 000 BTU hr Otros aparatos a gas ____BTU hr Calefactor de tiro natural 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr...

Page 40: ...laci n Debe proporcionar dos aberturas permanentes una dentro de 12 pulg del techo y otra dentro de 12 pulg del piso Conecte estos art culos directamente al exterior o a espacios abiertos al exterior...

Page 41: ...puede montar en la pared o en el piso usando las patas soportes Modelos seleccionados ADVERTENCIA Mantenga los espacios libres m nimos mostrados en Ver Fig 3 Si puede proporcione espacios libres m s...

Page 42: ...alar el accesorio del ventilador Contacte a una persona de servicio calificada para hacer esto 2 Retire el panel preperforado del ventilador del panel usando un destornillador Ver Fig 9 Instale el ven...

Page 43: ...orde de la mesa 3 Sujete las patas de soporte al calefactor usando los tornillos de las patas de soporte Fig 13 Nota Si el calefactor va a ser instalado directamente sobre alfombra baldosa u otro mate...

Page 44: ...ue solamente el ltimo agujero en cada extremo del soporte de montaje Inserte 2 tornillos para madera ST4 8 45 16 en total de a trav s de estos agujeros solamente 3 Retire la cinta y el soporte de mont...

Page 45: ...y en los soportes de expansi n 7 Apriete los expansi n tornillos del soporte ST4 8 15 16 hasta que el soporte de montaje est sujetado firmemente en la pared 8 Compruebe que el soporte est seguro antes...

Page 46: ...n de la l nea de gas es mayor la unidad no funcionar y podr an ocurrir da os al regulador del calefactor PRECAUCI N Nunca conecte el calefactor directamente a un suministro de PL Este calefactor requ...

Page 47: ...de prueba mayores de 1 2 PSIG 3 5kPa El aparato y su v lvula de gas principal deben estar desconectados del sistema de tuber a de suministro de gas durante cualquier prueba de presi n de ese sistema...

Page 48: ...toque ning n interruptor el ctrico no use ning n tel fono en su edificio LLame de inmediato a su proveedor de gas del tel fono de un vecino Siga las instrucciones del proveedor de gas Si no puede con...

Page 49: ...a presione el encendedor hasta que el piloto se encienda El piloto es visible centrado debajo del quemador principal detr s de la parrilla delantera Ver Fig 24 7 Mantenga oprimida la perilla de contro...

Page 50: ...CCI N DE LOS QUEMADORES Revise diariamente el patr n de la llama cuando est en uso y al menos una vez al a o por una agencia de servicio calificada PATR N DE LA LLAMA DEL PILOTO La Figura 26 muestra u...

Page 51: ...lla de control adjustada a llama alta 5 El tercio superior de la llama puede ser de color amarillo brillante cuando se opera con propano Cuando este calentador est configurado para su uso con gas prop...

Page 52: ...do puede provocar un incendio Para limpiar estas piezas recomendamos usar aire comprimido a no m s de 30 PSI Puede usar una aspiradora en la posici n de soplado Si usa aire comprimido en una lata siga...

Page 53: ...l encendedor no est conectado al cable del encendedor 4 El cable del encendedor est aplastado o h medo 5 Cable del encendedor da ado 6 Encendedor o m dulo de ignici n malo 7 Bater a mala 1 Reemplace e...

Page 54: ...e gas Ignici n retrasada del los quema dor es 1 La presi n del distribuidor es de masiado baja 2 El orificio del quemador est obstruido 1 Llame a su proveedor de gas 2 Limpie el quemador ver Cuidado y...

Page 55: ...loto ver Cuidado y man tenimiento p gina 51 Hay olor a gas inclu so cuando la perilla de control est en la posici n OFF 1 Fuga de gas Ver Declaraci n de advertencia en la parte su perior de la p gina...

Page 56: ...a AUTO 3 El motor del ventilador est malo 1 La carcasa o las aspas del ventilador est n sucias 2 La rotaci n del ventilador est bloqueada 3 Ventilador defectuoso 1 Ver Limpieza del ventilador p gina 5...

Page 57: ...Gas Natural 1 N A BF30K 39 NG L 950 N A BF30K 39 NG L 950 N A BF30K 39 NG L 950 4 Cable de encendido 1 BF30K 38 L 1050 BF30K 38 L 1050 BF30K 38 L 1050 5 V lvula de Gas Termost tica SIT 630 1 0630560...

Page 58: ...28...

Page 59: ...______________ PRECIO PAGADO __________________ Por favor t mese un minuto para darnos sus respuestas a las siguientes preguntas Todas las respuestas ser n usadas nicamente para investigaci n de merca...

Page 60: ...us registros Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Av...