Dyna-Glo BF10DTDG-4 Manual Download Page 1

1

VENT-FREE

BLUE FLAME

GAS WALL HEATER

MODEL #BF10DTDG-4

BF20DTDG-4
BF30DTDG-4 

GBF30DTDG-4

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

WARNING: 

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY 

DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

WARNING:

 This appliance is equipped for

Natural and Propane gas. Field conversion is 

not permitted.

- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or 

  any other appliance.
  WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

instructions.

• If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or the

gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided.

Refer to Air For Combustion and Ventilation section on page 8 of this manual.

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) 

home, where not prohibited by local codes. 

This appliance is only for use with propane or natural gas. 

This appliance is equipped with a simple means to switch between propane and natural gas. 

Field conversion by any other means including the use of a kit is not permitted.

C           US

WARNING

: Do not attempt to access or change

the setting of the fuel selection means.
Access to and adjustment of the fuel selection means 

must only be performed by a qualified service person 

when connecting this appliance to a specified fuel 

supply at the time of installation.
Change of the selector setting to other than the fuel type 

specified at the time of installation could damage this 

appliance and render it inoperable.
The installer shall replace the access cover before 

completing the installation and operating this appliance.

C           US

 ANS Z21.11.2-2016

Gas Fired Room Heaters

Volume II - Unvented Room Heaters

Questions, problems, missing parts?

 Before returning to your retailer, call our customer 

service department at 1-877-447-4768,

 

8:30 a.m. –  4:30

 

p.m., CST, Monday – Friday or 

email us at [email protected].

 IMDFBFG4 - 2019-03-25

Patent Pending Dual 

Fuel System

Summary of Contents for BF10DTDG-4

Page 1: ...Refer to Air For Combustion and Ventilation section on page 8 of this manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by loc...

Page 2: ......

Page 3: ...uel Type Natural Gas Propane Natural Gas Propane Ignition Electronic Push Button Electronic Push Button Manifold Pressure 5 in W C 10 in W C 5 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14...

Page 4: ...ance is intended for supplemental heating This appliance can be used with propane or natural gas It is shipped from the factory adjusted for use with propane CARBON MONOXIDE POISONING Early signs of c...

Page 5: ...nder dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater and pilot off If heated the vapors from these products may create a white powder residue within...

Page 6: ...DELS The fan kit helps to distribute the warmed air into the space more rapidly NOTE This is an optional accessory and is not required for operation of the heater State of Massachusetts The installati...

Page 7: ...roximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemen...

Page 8: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are c...

Page 9: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Page 10: ...ms directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for requ...

Page 11: ...e support legs Select models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining wall Fig 3 Mounting clearances as viewed fr...

Page 12: ...cked positions 3 Remove plug from the inlet of the NG regulator 4 If the LP plug was removed previously apply thread sealant to ensure that there are no leaks and install the NG plug into the inlet of...

Page 13: ...anel using a screwdriver See Fig 9 Attach Fan to the rear panel of the heater using the four screws provided NOTE Be sure the rocker switch is positioned in the upper right corner See Fig 10 3 This fa...

Page 14: ...crews M4 15 1 Set down a blanket onto the table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom...

Page 15: ...mounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wo...

Page 16: ...ole on each end of bracket with expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16...

Page 17: ...ust be a minimum 6 WC for NG 11 WC for LP with a max pressure of 14 WC for NG 14 WC for LP If gas line pressure is higher regulator damage could occur CAUTION Never connect heater directly to an LP su...

Page 18: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Page 19: ...service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 STOP Read the safety...

Page 20: ...itor button until the pilot lights The pilot is visible centered below the main burner behind the front grill l See Fig 24 7 Keep control depressed for 30 seconds after pilot lights Release control kn...

Page 21: ...PERATION Manual valves remain burning at the desired setting until manually turned to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic OPERATION INSPECTING BURNERS Check pilot flame pat...

Page 22: ...th Control Knob Set to High Flame 5 NOTE Ambient flame burners produce both a blue and yellow flame An excessively high yellow colored flame may be caused by airborne dust dander pet hair etc Addition...

Page 23: ...ir no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could...

Page 24: ...trode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor module or ignition module 1 Replace ODS 2 Replace ODS 3 Replace ignitor cable 4 Free ign...

Page 25: ...Not enough air 2 Gas regulator is defective 3 Wrong gas type selected 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 21 2 Replace gas regulator 3 See Gas Select...

Page 26: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate...

Page 27: ...TROUBLESHOOTING QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equip...

Page 28: ...60 7 Manual Gas Valve 1 GS7A GHP GS7E GHP GS7D GHP GS7D GHP 8 Gas Selector Valve 1 GH01A 10K GH01A GH01A GH01A 9 Regulator Bracket 1 AQ000015 AQ000015 AQ000015 AQ000015 10 1 Regulator LP Propane 10 WC...

Page 29: ..._________________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please T...

Page 30: ...ds SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 828...

Page 31: ...e acceder a o cambiar el ajuste de los medios de selecci n del combustible El acceso a y el ajuste de los medios de selecci n de combustible deben ser realizados solamente por personal de servicio cal...

Page 32: ......

Page 33: ...pulg de columna de agua 10 pulg de columna de agua 5 pulg de columna de agua 10 pulg de columna de agua Presi n de gas de entrada M ximo 14 pulg de columna de agua 14 pulg de columna de agua 14 pulg d...

Page 34: ...evisto para calefacci n complementaria Este aparato puede ser usado con propano o gas natural Es enviado de la f brica ajustado para ser usado con propano PELIGRO DE ENVENENAMIENTO CON MON XIDO DE CAR...

Page 35: ...lamables Bajo condiciones de mucho polvo 7 Antes de usar pulidor de mueble cera limpiador de alfombra o productos similares apague el calefactor y el piloto Si se calientan los vapores de estos produc...

Page 36: ...ADOR MODELOS SELECCIONADOS El juego del ventilador ayuda a distribuir el aire caliente dentro del espacio m s r pidamente NOTA Este es un accesorio opcional y no es necesario para el funcionamiento de...

Page 37: ...aproximadamente 1 onza 30 mL de agua por cada 1 000 BTUs 0 3 Kw de entrada de gas por hora Un calefactor no ventilado de habitaci n est previsto como un calefactor complementario en lugar de una fuen...

Page 38: ...con puertas son consideradas una parte del espacio no confinado Este calefactor no deber ser instalado en un espacio confinado o construcci n inusualmente herm tica a menos que se tomen medidas para u...

Page 39: ...Ejemplo Le os de calentador a gas __________BTU hr Calentador de agua a gas 30 000 BTU hr Otros aparatos a gas ____BTU hr Calefactor de tiro natural 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr...

Page 40: ...do rejillas o ductos de ventilaci n Debe proporcionar dos aberturas permanentes una dentro de 12 pulg del techo y otra dentro de 12 pulg del piso Conecte estos art culos directamente al exterior o a e...

Page 41: ...ueroseno etc en el aire puede hacer que las paredes se decoloren ESPACIOS LIBRES PARA COMBUSTIBLES Siga las siguientes intrucciones con mucho cuidado Este calefactor se puede montar en la pared o en e...

Page 42: ...s bloqueadas 3 Retire el tap n de la entrada del regulador de GN 4 Si se retira el tap n de PL usar sellador de rosca para garantizar que no hayan fugas vuelva a colocar el tap n en la entrada del reg...

Page 43: ...or Ver Fig 9 Instale el ventilador en el panel trasero del calefactor usando los cuatro tornillos proporcionados NOTA Aseg rese de que el interruptor oscilante est colocado en la esquina superior dere...

Page 44: ...sobre la mesa donde se colocar el calentador para prevenir que la instalaci n de la pierna evite rallar la mesa o el calentador 2 Coloque la parte de atr s sobre la mesa con el fon do del calefactor e...

Page 45: ...er Fig 16 Nota Marque solamente el ltimo agujero en cada extremo del soporte de montaje Inserte 2 tornillos para madera ST4 8 45 16 en total de a trav s de estos agujeros solamente 3 Retire la cinta y...

Page 46: ...y en los soportes de expansi n 7 Apriete los expansi n tornillos del soporte ST4 8 15 16 hasta que el soporte de montaje est sujetado firmemente en la pared 8 Compruebe que el soporte est seguro antes...

Page 47: ...para el GN y 11 WC de PL con una presi n m xima de 14 WC para el GN y 14 WC de LP Si la presi n de la l nea de gas es m s alta da os al regulador podr a ocurrir PRECAUCI N Nunca conecte el calefactor...

Page 48: ...r as del suministro de gas Presiones de prueba mayores de 1 2 PSIG 3 5kPa El aparato y su v lvula de gas principal deben estar desconectados del sistema de tuber a de suministro de gas durante cualqui...

Page 49: ...e el aparato y reemplace cualquier pieza del sistema de control y cualquier control del gas que haya estado bajo el agua INSTRUCCIONES DE ENCENDIDO CONTROL MANUAL DEL GAS 1 ALTO Lea la informaci n de...

Page 50: ...apaga repita los pasos 3 al 7 Espere 1 minuto antes de intentar encender el piloto de nuevo Si despu s de varios intentos el piloto todav a se apaga gire la perilla de control hacia la derecha a la po...

Page 51: ...5 Fig 25 Posici n de la perilla de control Manual Termost tico OPERACI N INSPECCI N DE LOS QUEMADORES Revise diariamente el patr n de la llama cuando est en uso y al menos una vez al a o por una agenc...

Page 52: ...lla de control adjustada a llama alta 5 El tercio superior de la llama puede ser de color amarillo brillante cuando se opera con propano Cuando este calentador est configurado para su uso con gas prop...

Page 53: ...estas piezas recomendamos usar aire comprimido a no m s de 30 PSI Puede usar una aspiradora en la posici n de soplado Si usa aire comprimido en una lata siga las instrucciones en la lata Si no sigue...

Page 54: ...o o h medo 5 Cable del encendedor da ado 6 M dulo del Encendedor o m dulo de ignici n malo 1 Reemplace el ODS 2 Reemplace el ODS 3 Reemplace el cable del encendedor 4 Libere el cable del encendedor si...

Page 55: ...ma dor es 1 La presi n del distribuidor es de masiado baja 2 El orificio del quemador est obstruido 1 Llame a su proveedor de gas 2 Limpie el quemador ver Cuidado y Manteni miento p gina 52 o llame a...

Page 56: ...loto ver Cuidado y man tenimiento p gina 52 Hay olor a gas inclu so cuando la perilla de control est en la posici n OFF 1 Fuga de gas Ver Declaraci n de advertencia en la parte su perior de la p gina...

Page 57: ...ACCI N CORRECTIVA CAUSA POSIBLE PROBLEMA AGENCIA DE INSTALACI N CALIFICADA Solo una agencia calificada debe efectuar la instalaci n y el reemplazo de las tuber as de gas del equipo o los accesorios e...

Page 58: ...0630560 7 Valvula Manual de Gas 1 GS7A GHP GS7E GHP GS7D GHP GS7D GHP 8 Valvula Selectora de Gas 1 GH01A 10K GH01A GH01A GH01A 9 Soporte del Regulador 1 AQ000015 AQ000015 AQ000015 AQ000015 10 1 PL Ens...

Page 59: ...nt as como est n descritas dentro de este documento no aplican a accesorios que no son del fabricante usadas junto con la instalaci n de este producto Esta garant a no tiene validez si a El producto h...

Page 60: ...gistro de la garant a en el plazo de catorce 14 d as despu s de la fecha de compra Tambi n puede registrar su garant a en internet en www ghpgroupinc com Complete el n mero de serie Conserve esta porc...