U S E R G U I D E
|
B L U E W A V E M X - 2 5 0 E M I T T E R S
9
Troubleshooting & Maintenance
Problem
Possible Cause
Corrective Action
BlueWave MX-250
LED does not
produce light
LED intensity adjustment
set to 0% or too low
Increase LED intensity setting.
LED cycle time is set to
0 seconds
0 Seconds sets manual mode and
requires a trigger.
Interlock is open
Verify interlock jumpers are in place.
Verify PLC command structure for
PLC mode.
Interface cable connections
loose or damaged
Check connections and condition of
interface cable.
Trigger setting not
matched to input
Trigger setting on admin screen
should match the desired input trigger
channel.
LED head is not connected
to the correct port/channel
Verify that the head is connected to the
desired port/channel.
BlueWave MX-250
LED suddenly
stops producing
light
Over-temperature
shutdown was triggered
Verify alarms.
Footswitch defective
Activate unit using the front control
panel. Replace the footswitch if the
unit operates from the front control
panel.
Interlock is open
Verify interlock jumpers are in place.
Verify PLC command structure for
PLC mode.
BlueWave MX-250
LED provides only
low-intensity light
LED intensity adjustment
set to minimum
Increase LED intensity setting on
admin settings or I/O input for PLC
mode.
Contaminated/dirty lens
optics
Clean the surface of the lens.