DS10-P-02
OPERATING MANUAL
Page 1: ...DS10 P 02 OPERATING MANUAL ...
Page 2: ... and Liquids Serviceability Specification 3 Material and Temperature Range 4 Exploded View Drawing 5 Screws Torque Guide 7 Dimensions 8 Important Safety Information 10 Installation Considerations 11 Installation Instructions 12 FAQ 13 Warranty Instructions 14 ...
Page 3: ...ion below Note PPG Polypropylene add Bolivian filament ent Current specificalion Size Wetted Body Center Body Pupe Type Diaphragm Ball cover Ball Ball seat Edition 10 1 P PPG A Aluminum F Center Flange U UPE P PP S S S 316 P PP 02 L Flank Flange T PTFE TFM E PE T PTFE E PE O Santoprene ...
Page 4: ...nyl Chloride Ammonia Asphalt Sulfuric Acid Chromic Acid Electroplate Solu on High Temperature Sauce Chili Sauce Coal Oil Vola le Oil Carrier Oil Immiscible Fluids Freezing Mixture Degreasing Agent Methylene Chloride Jam Juice Ace c Acid Leavan Slops Balsam Olive Oil Defoamer DSXX SAX OXSO X Glaze Po ery Clay Thick Liquid Bolivian Filament Note Depending on the density temperature concentration and...
Page 5: ... thermoplas c vulcanizates TPVs are high performance elastomers which offer manufacturing flexibility ease of processing and durability It combines the characteris cs of vulcanized rubber with the processing proper es of thermoplas cs 40 135゚C Polyethylene PE The thermoplas c resin is made by polymeriza on of ethylene which is also includes a polymer of ethylene and a small amount of the polyethylen...
Page 6: ...15 16 17 13 22 53 54 32 35 38 36 37 56 41 43 45 55 40 42 11 1 5kg cm 2 JIS B 2211 1977 G45 59 57 60 SPARE SEAL Consumptive Parts Possible 2016 01 DS10 PAFXXTX 02 1 2 2 2 4 2 2 2 2 2 2 4 2 11 2 2 2 2 2 2 17 2 2 19 2 2 2 1 1 1 1 1 1 1 1 4 1 1 1 1 1 2 1 1 41 1 1 2 44 1 45 4 2 47 49 1 51 2 52 4 1 1 2 1 1 2 4 ...
Page 7: ...hragm 2 PD000085 SingleDiaphragm 2 PD000086 17 PadOfDiaphragm 2 PA000225 18 Oring 2 PD000010 19 ShaftCover 2 PB000176 20 Oring 2 PD000009 21 Oring 2 PD000007 22 ShaftOfDiaphragm 1 PA000084 23 BodyOfThimbleValve 1 PA000189 24 Oring 1 PD000017 25 Oring 1 PD000006 26 Oring 1 PD000004 27 Oring 3 PB000088 28 Oring 3 PD000025 29 Oring 1 PD000002 30 Thimble 1 PA000201 31 ThimbleCap 1 PB000361 32 HexagonS...
Page 8: ...000 0 01 0 868 0 072 1 kgf m 9 8066 981 100000 100 86 8 7 233 1 lbf in 0 113 11 3 1150 1 152 0 0115 0 083 1 lbf 1 355 136 13800 13 83 0 138 12 Unit Imperial Unit Tension to Torque Conversion SI Gravity Unit Posi on Name Torque Values kgf cm 52 3 4 Hexagon Bung 165 180 Max 45 M6 Hexagon Screw 18 5 20 Max 14 M10 Steel Hexagon Screw 165 175 Max 3 M8 Hexagon Screw 85 100 Max 1 2 M8 Hexagon Screw 100 1...
Page 9: ...8 DIMENSIONS 170 228 254 364 50 Fluid Outlet 1 Fluid Inlet 1 105 149 296 204 Air Inlet 3 8 ...
Page 10: ...9 DIMENSIONS 311 218 168 Fliud Outlet 1 ANSI 150R F 110m m Fliud Inlet 1 ANSI 150R F 110m m 307 20 50 419 367 50 177 50 133 50 204 AIR INLET 3 8 ...
Page 11: ...10 IMPORTANT SAFETY INFORMATION ...
Page 12: ...ies If too much wastewater is introduced into the pump body the wastewater and lubricating oil will emulsify and affect the lubrication of the parts or block the pores thereby affecting the operation performance of the pump or causing malfunction Air Line Moisture Water in the compressed air supply can create problems such as icing or freezing of the exhaust air causing the pump to cycle erratical...
Page 13: ...le connection Pipe Connection Style Optional Pipe Connection Style Optional Flexible connection Gauge Gauge Shut Off Valve Shut Off Valve Drain Port Drain Port Discharge Suction Air inlet Air shut Off Valve Modular Type F R L Unit INSTALLATION INSTRUCTIONS ...
Page 14: ...mp whether lubricates sufficient or not Please clean up the dirty parts and relubrication It is recommended to add lubricating oil to the air pressure inlet pipeline every half year don t exceed 10ml each time c Sequential valve abnormal If the deterioration of the sequential if it is worn please change it d Compressed Air Lines Freezing The Slithery Mass Valve 53 might be frozen because of low te...
Page 15: ...of the original quality of the product we will change a new one for you Improper use e g Falling Attacked Liquid input etc or abnormal operating conditions e g Flood Fire Earthquake Lightning strike Typhoon etc these damages are not covered by the warranty Improper installation self modifying wear and tear caused by not transporting in accordance with machine regulations Accident or defect caused ...