Dyer PS-24-1-U Original Instructions Download Page 1

PS-24-1-U

99.827.11 1.0/07/16

1/2

English

Original instructions

Example for Application

rain detector*

external control*

ventilation drive*

vent button*

*  optional function extension 

(separate components retrofitable)

Safety notes

Operating voltage 230 V AC!
Risk of injury from electric shock!
Connection must be carried out by a certified electrical technician.

-   Use only in dry rooms.
-   Do not lay 24 V DC and 230 V AC cables in the same cable duct!
-   Use unmodified original parts only.
-   Observe the drive instructions for use.

Intended use

-  Compact ventilation control for separate rooms and conservatories
-  For triggering of 24 VDC drives
-  1 ventilation group
-  1 A total actuating current
-  Ventilation safety function (key operation OPEN/CLOSE)
-  Possibility of connecting rain detector or wind/ rain detector
-  For installation in branch box provided on site
-  Only for inside mounting

Technical Data

Type 

: PS-24-1-U

Power supply 

: 230 V AC 50 Hz

Power 

: 30 VA

Class of rating 

: short-time duty, 20%

Output 

: 24 V DC, max. 1 A

Ripple 

: <= 1%

Ingress protection  : IP 30
Temp. range 

: -0 ... +50 °C

Housing 

: plastic

Dimensions 

: 50 x 48 x 28 mm WxHxD

Disposal

Electrical devices, accessories, batteries and packaging should be sorted for 
environmental-friendly recycling.
Do not dispose electrical devices and batteries into household waste!
Only for EC countries:
According  the  European  Guideline  2012/19/EU  for  waste  electrical  and 
electronic  equipment  and  its  implementation  into  national  right,  electrcal 
devices that are no longer usable must be collected separately and dispo-
sed of in an environmentally correct manner.

PS-24-1-U

X2

N

b

IN:
230V

AC / 30V

A

OUT

:

24VDC / 
1A

2

mA

max.

50

IP 30

30.241.61

T

emp.: 0°C...+55°C

C

3

4

5

6

7

1

L

X1

24V

a

Power

supply

WARNING

Read all safety warnings, instructions, illustrations and specifications 
provided with this product.
Failure to follow all instructions listed below may result in electric shock, 
fire and/or serious injury.
Save all warnings and instructions for future reference.

Maintenance and cleaning

Maintenance  work  is  only  allowed  when  the  device  is  in  a  de-energized 
condition! Inspection and maintenance has to be carried out according to D+H 
maintenance notes. Only original D+H spare parts may be used. Repair is to be 
carried out exclusively by D+H.
Wipe away debris or contamination with a dry, soft cloth.
Do not use cleaning agents or solvents.

PS-24-1-U

X2

N

b

IN:
230V

AC / 30V

A

OUT

:

24VDC / 
1A

2

mA

max.

50

IP

 30

30.241.61

T

e

m

p

.:

 0

°C

..

.+

5

5

°C

C

3

4

5

6

7

1

L

X1

24V

a

Power

supply

Reviews: