background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for DCP-122

Page 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Page 2: ...333 Palladium Drive Kanata Ontario Canada K2V 1A6 613 599 9199 SCP DCP 122 3U COMPACTPCI SINGLE BOARD COMPUTER GETTING STARTED MANUAL 812628 1 October 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...onsent of Dy 4 Systems Inc The proprietary information contained in this document must not be disclosed to others for any purpose nor used for manufacturing purposes without written permission of Dy 4 Systems Inc The acceptance of this document will be construed as an acceptance of the foregoing condition Copyright 2003 Dy 4 Systems Inc All rights reserved TRADEMARKS Flash is a trademark of Seeq T...

Page 4: ... Sequence Control Jumper 2 9 Backup FPGA Boot PROM Jumper Reserved 2 10 3 Installing PMC Modules on the SCP DCP 122 3 1 Before You Begin 3 1 Installation Procedure 3 2 Unpack and Configure the Card 3 2 Install the PMC Module on the SCP DCP 122 3 2 4 Hardware Installation 4 1 Introduction 4 1 Inserting the Card in a Chassis 4 2 Before You Begin 4 2 About Card Insertion Force 4 2 Choosing a Slot Loc...

Page 5: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC IV 812628 REVISION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 6: ...r 2 7 Figure 2 6 Watchdog Timer Power up Jumper 2 8 Figure 2 7 Execution Sequence Control Jumper 2 9 Figure 2 8 FPGA Boot PROM Select 2 10 Figure 3 1 Installing a PMC Module on a DCP 122 3 3 Figure 4 1 SCP 122 Terminal Connection via BPK 122 000 Transition Module 4 3 Figure 4 2 Digital I O via the Transition Module 4 5 Figure 4 3 EIA 422 Channel 3 and Channel 4 Header Pins 4 7 Figure 4 4 Using the...

Page 7: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC VI 812628 VERSION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 8: ...Channel 1 RS 232 Connector BPK 122 000 J3 Pinout 4 4 Table 4 2 Serial Channel 2 RS 232 Connector BPK 122 000 J6 Pinout 4 4 Table 4 3 USB Connector BPK 122 000 J4 Pinout 4 4 Table 4 4 Ethernet Connector BPK 122 000 J5 Pinout 4 5 Table 4 5 DIO Header Pinout 4 6 Table 4 6 EIA 422 Channel 3 Pinout 4 7 Table 4 7 EIA 422 Channel 4 Pinout 4 7 Table 4 8 Transition Module P0 Row A Signal Mapping 4 10 Table...

Page 9: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC VIII 812628 VERSION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 10: ...ntents hardware functional description detailed connector pinout info programming interface description including registers memory maps etc SCP DCP 122 Getting Started Manual 812628 Contents product overview hardware jumper configuration unpacking and installation cable hook up and initial system check out SCP DCP 122 Hardware Documentation SCP DCP 122 Software Documentation SCP DCP 122 Foundation...

Page 11: ...cautions Typographic Conventions Table 1 lists the typographical conventions used in documents contained in this document and the associated documentation package Signal Conventions Table 2 shows symbols which can follow a signal name For example the octothorpe is used with a PCI signal name such as TRDY TABLE 1 Typographical Conventions Item Convention Example Keystrokes Keys are listed as they a...

Page 12: ...ing icon indicates procedures in the manual that if not carried out or if carried out incorrectly could cause physical injury electrical damage to equipment or a non recoverable corruption of data Warnings include instructions for preventing such damage Please observe warning icons and read the accompanying text completely before carrying out the procedure The caution icon indicates non catastroph...

Page 13: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC XII 812628 VERSION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 14: ...le board computer on the market today Based on the IBM 750FX processor it runs at a clock speed of 800 MHz while executing an impressive 1856 Dhrystone Millions of Instructions per Second DMIPS No other rugged COTS 3U cPCI single board computer can match the raw processing power of the SCP DCP 122 FIGURE 1 1 DCP 122 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www arti...

Page 15: ...C capable EIA 422 serial channels 2 asynchronous or 1 synchronous 1 x USB 8 x general purpose DMA controllers Up to 16 bit Discrete I O PMC EXPANSION To extend system flexibility and enhance system functionality through expansion the SCP DCP 122 provides a full speed 64 bit 33 66 MHz PMC site directly on the basecard A complement of Dy 4 PMC s have been tested and qualified over temperature shock ...

Page 16: ...PMC Conn PN1 2 3 J1 Conn PMC Conn PN4 termination 10 100 transceiver RS232 transceiver 422 Xceivers I O Mux Scheme IBM750FX 512K L2 Cache 800MHz DH DL Adr Ctrl CPU I F PCI 0 I F PCI 1 I F SDRAM I F Ethernet I F Serial I F I2C I F MPP I F Device I F Clocks Temp Sensor Flash Bank 0 32MBytes Flash Bank 1 32MBytes USB Host Controller PABS 32 bit 33 66 MHz 5 3 3 Volt Non Muxed I O Pins Muxed I O Pins 1...

Page 17: ...the SCP DCP 122 Although the SCP 122 is used for illustration purposes the board layout for the DCP version product is identical FIGURE 1 3 SCP 122 Component Side View FIGURE 1 4 SCP 122 Solder Side View GT 64260 Discovery IBM750FX J1 J2 SDRAM SDRAM PN4 PN3 PN2 PN1 SDRAM SDRAM SDRAM Flash Flash Flash Flash Flash PABS USB Eth Phy Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SO...

Page 18: ... MATING CONNECTORS The locations of the connectors on the SCP DCP 122 are shown in Figure 1 3 Backplane Connectors The SCP DCP 122 incorporates J1 and J2 connectors as specified in the PICMG compact PCI specification 2 0 Revision 3 0 PMC Connectors In order to support the mounting of a single PCI Mezzanine Card PMC in accordance with the IEEE 1386 2001 standard the SCP DCP 122 includes the Pn1 Pn2...

Page 19: ...mpling of product over a limited operating temperature range with no PMC module installed VOLTAGE REQUIREMENTS The SCP DCP 122 expects the following voltages to be available from the compact PCI backplane as specified in the PICMG specification 5V 3 3V VIO 12V and 12V Voltage Maximum Current Typical Current 3 3V 5 3 1 1 A 0 9 A 5V 5 3 2 2 A 1 8 A 12V 0 6V 5 0 A Not used by the base card only route...

Page 20: ...s boot up Non Volatile Memory Programmer NVMP provides for in circuit programming of Flash memory BOARD SUPPORT PACKAGES DRIVERS Support is provided for the VxWorks operating system The VxWorks boot loader is pre loaded on the SCP DCP 122 hardware Refer to the BSP Release Notes and the BSP Software User s Manual delivered on the BSP s w CD ROM for additional information Cross Reference Refer to th...

Page 21: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC 1 8 812628 VERSION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 22: ... present during unpacking and inspection 2 Find the packing list Verify that all the items on the list are present 3 Save the packing material for storing or reshipping the card Warning This card uses components that are sensitive to electrostatic discharges It must be kept in its conductive package until just before the installation begins Remove the card from its protective package only at a gro...

Page 23: ...ot Write Protect Connect E1 E2 Open E1 E2 Flash Application Bank Write Protect Enable Disable Disable Flash Application Bank Write Protect Enable Flash Application Bank Write Protect Connect E3 E4 Open E3 E4 Enable Writes to Permanent Alternate Boot Site PABS Memory Disable Permanent Alternate Boot Bank Write Protect Enable Permanent Alternate Boot Bank Write Protect Connect E5 E6 caution for fact...

Page 24: ...e SCP DCP 122 however it has not been imple mented at the present time meaning the jumper at E13 E14 must not be connected Open E13 E14 TABLE 2 1 Jumper Settings Summary Continued Note All other E jumper locations not specifically mentioned in the above table are reserved for factory use E1 E3 E5 E7 E9 E11 E13 E2 E4 E6 E8 E10 E12 E14 Artisan Technology Group Quality Instrumentation Guaranteed 888 ...

Page 25: ...ode the WP_BOOT_BIT described further in E2PROM General Control Register in Chapter 3 of the SCP DCP 122 Hard ware User s Manual is Read Only Connect E1 E2 In this mode application software can change the WP_BOOT_BIT to write protect or not described further in E2PROM General Control Register in Chapter 3 of the SCP DCP 122 Hardware User s Manual E5 E7 E9 E11 E13 E6 E8 E10 E12 E14 E3 E4 E1 E2 Cros...

Page 26: ...E4 jumper FIGURE 2 3 Application Flash Write Protect Jumper Cross Reference The state of the E3 E4 jumper is shown in the WR_PROT_APP_JMP bit in the FPGA Miscellaneous Signal Status Register See Chapter 3 of the SCP DCP 122 Hardware User s Manual for more information about the Miscellaneous Signal Status Register TABLE 2 3 Application Flash Write Protect Jumper Option Jumper Setting Application Fl...

Page 27: ...intended for factory use only Cross Reference The state of the E5 E6 jumper is shown in the WR_PROT_PABS_JMP bit in the FPGA Miscellaneous Signal Status Register See Chapter 3 of the SCP DCP 122 Hardware User s Manual for more information about the Miscellaneous Signal Status Register TABLE 2 4 PABS Flash Write Protect Jumper Option Jumper Setting PABS Flash Write Protect Enable programming of PAB...

Page 28: ...en power off the card and remove the jumper to allow local booting Use the jumper settings described in Table 2 5 to select the bank used for booting The location of the jumper is shown in Figure 2 5 below FIGURE 2 5 Boot From PABS Memory Jumper TABLE 2 5 Enable Booting from PABS Memory Option Jumper Setting Boot from 8 bit PABS site Boot from 32 bit main Flash Connect E7 E8 Open E7 E8 Note The fu...

Page 29: ...ft to expire With the E9 E10 jumper installed the watchdog timer is disabled following power up reset however it can be enabled by application software FIGURE 2 6 Watchdog Timer Power up Jumper TABLE 2 6 Watchdog Timer Power up Behaviour Option Jumper Setting Watchdog timer is disabled following power up generates interrupt on timeout Watchdog timer is enabled following power up generates a card r...

Page 30: ...ore information For information on the code executed refer to the SCP DCP 122 Programmer s Reference Manual Factory configurations are performed via the installation removal of configuration resistors Please contact the factory if you require information about factory configured options Under normal circumstances you should not need to alter any of the factory configured options FIGURE 2 7 Executi...

Page 31: ...ust be removed in order to use the normal FPGA boot PROM FIGURE 2 8 FPGA Boot PROM Select TABLE 2 8 Backup FPGA Boot PROM Select Option Jumper Setting Backup FPGA Boot PROM Reserved A provision for a Back up PROM for the FPGA exists in the design of the SCP DCP 122 however it has not been imple mented at the present time meaning the jumper at E13 E14 must not be connected Open E13 E14 E1 E5 E7 E2 ...

Page 32: ...allation begins Remove the card from its protective package only at a grounded workstation while wearing an approved grounding wrist strap Avoid touching any metal contacts on the card static discharge can damage integrated circuits To avoid damage to the card or to avoid any personal injury remove the power from the chassis prior to removing or installing cards Artisan Technology Group Quality In...

Page 33: ...les to match the holes in the primary and secondary thermal interfaces five holes on the primary interface and three holes on the secondary Remove the backing from the thermal gaskets and affix them to the thermal frame of your PMC module Your mounting kit may include thermal pads of a thicker material to conduct heat away from some components through the thermal frame on the carrier card Remove t...

Page 34: ...E SCP DCP 122 812628 VERSION 1 OCTOBER 2003 3 3 FIGURE 3 1 Installing a PMC Module on a DCP 122 2 5 mm screws 2 mm screws w washers typ Integral Standoffs Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 35: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC 3 4 812628 VERSION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 36: ...ting a terminal to the card via a serial communications cable connecting other devices to the card via the BPK 122 000 Transition Module turning on the power and confirming that the Power up Built In Test PBIT has com pleted successfully displaying the initial screen message and establishing the card s PCI base address troubleshooting installation problems Artisan Technology Group Quality Instrume...

Page 37: ...CI bus arbitration clocks terminations system reset PCI configuration If the SCP DCP 122 is inserted into any of the peripheral slots marked with a circle it functions as a peripheral card A peripheral card requires a system controller to provide the above functions Warning This card uses components that are sensitive to electrostatic discharges It must be kept in its conductive package until just...

Page 38: ...ule BPK 122 000 TRANSITION MODULE The BPK 122 000 Transition Module is used to access the user s I O from the CPCI chassis backplane The 122 I O consists of two RS 232 serial ports channel 1and channel 2 two EIA 422 serial ports channel 3 and channel 4 The 422 channels can be config ured as two independent asynchronous channels or one synchronous channel Ch4 data becomes CH3 clock one 10 Base T 10...

Page 39: ...summarizes the pinout information for the BPK 122 000 J4 connector TABLE 4 1 Serial Channel 1 RS 232 Connector BPK 122 000 J3 Pinout J3 Pin Number SCP DCP 122 Signal Name 1 No Connect 2 No Connect 3 RX 4 TX 5 DSR 6 GND TABLE 4 2 Serial Channel 2 RS 232 Connector BPK 122 000 J6 Pinout J6 Pin Number SCP DCP 122 Signal Name 1 No Connect 2 No Connect 3 RX 4 TX 5 No Connect 6 GND TABLE 4 3 USB Connecto...

Page 40: ...e transition module as shown below in Figure 4 2 The center column of pins are GND signals FIGURE 4 2 Digital I O via the Transition Module TABLE 4 4 Ethernet Connector BPK 122 000 J5 Pinout J5 Pin Number SCP DCP 122 Signal Name 1 ENET_TX 2 ENET_TX 3 ENET_RX 4 NC 5 NC 6 ENET_RX 7 NC 8 NC J2 CPCI J4 USB J5 Eth RS 422 Ch 3 and Ch 4 DIO P0 Cable I F Reset E36 E37 DIO1 DIO7 DIO8 DIO15 DIO J3 RS 232 J6...

Page 41: ... Signal Name DIO Pin Number Signal Name E1 DIO0 RTC Standby E9 GND E17 DIO8 E2 DIO1 E10 GND E18 DIO9 E3 DIO2 E11 GND E19 DIO10 E4 DIO3 E12 GND E20 DIO11 E5 DIO4 E13 GND E21 DIO12 E6 DIO5 E14 GND E22 DIO13 E7 DIO6 E15 GND E23 DIO14 E8 DIO7 ALTBOOT E16 GND E24 DIO15 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 42: ...CP 122 Signal Name Differential I O Pair E25 422_CH3_TX Diff I O Out 0 E26 422_CH3_TX E27 422_CH3_RX Diff I O In 0 E28 422_CH3_RX E29 GND TABLE 4 7 EIA 422 Channel 4 Pinout Pin Number SCP DCP 122 Signal Name Differential I O Pair E30 422_CH4_TX CH3_TXClock Diff I O Out 1 E31 422_CH4_TX CH3_TXClock E32 422_CH4_RX CH3_RXClock Diff I O In 1 E33 422_CH4_RX CH3_RXClock E34 GND J2 CPCI J4 USB J5 Eth RS ...

Page 43: ... following combination of interfaces two RS 232 ports available on Transition Module J3 and J6 connectors 64 bit PMC I O available on the 78 Way connector via the P0 cable into which the PMC 601 cable assembly 901321 000 may be connected to further break out the MIL STD 1553 signals Ethernet is available on J5 and it is also accessible via the P0 cable USB is not available multiplexed with PMC I O...

Page 44: ...the on board pin headers one 10 Base T 100 Base TX Ethernet Port available on J3 native connector and P0 cable one USB port available only on J4 native USB connector 12 bits of parallel I O available via the P0 cable but all 16 DIO are accessible via the on board pin headers four pairs of TMDS signals accessible via the DVI connector on the P0 cable one VGA interface Figure 4 5 below illustrates t...

Page 45: ...T2_UTP2 ENET_GND1 NC 2 ENET2_TXD ENET_TXD ENET_TX J2 E21 3 ENET2_RXD ENET_RXD ENET_RX J2 C21 4 PMC_05 TXC GND PMC_05 J2 C18 5 PMC_10 PMC_10_DIO3 J2 C19 6 PMC_15 PMC_15_422TX J2 B15 7 PMC_20 PMC_20 J2 B13 8 PMC_25 PMC_25 J2 D13 9 DIO 0 RTC PIO 0 PMC_06_DIO0_RTC J2 E16 10 DIO 7 ALT_BOOT PMC_33_ALTBOOT J2 C11 11 DIO 12 PMC_27_DIO12 J2 E12 12 PMC_30 PMC_30_DIO15 J2 A12 13 PMC_35 TX1 PMC_35 J2 E11 14 P...

Page 46: ...04 J2 A18 5 PMC_09 PMC_09_DIO2 J2 A17 6 PMC_14 PMC_14_USBD J2 D20 7 PMC_19 PMC_19_422RX J2 E14 8 PMC_24 PMC_24 J2 E19 9 DIO 1 PIO 1 PMC_07_DIO1 J2 B17 10 DIO 2 PIO 2 PMC_09_DIO2 J2 A17 11 VCC_USB2 PMC_08_USBVB J2 D19 12 PMC_29 PMC_29_DIO14 J2 D12 13 PMC_34 TX1 PMC_34 J2 B11 14 PMC_39 PMC_39_DIO9 J2 E10 15 PMC_44 HSYNC RTN PMC_44 J2 A9 16 PMC_49 PMC_49 J2 D8 17 PMC_54 BLUE RTN PMC_54 J2 A7 18 PMC_5...

Page 47: ...3 J2 D18 5 PMC_08 PMC_08_USBVB J2 D19 6 PMC_13 PMC_13_DIO5 J2 A16 7 PMC_18 PMC_18 J2 A14 8 PMC_23 PMC_23_DIO6 J2 E13 9 DIO 3 PIO 3 PMC_10_DIO3 J2 C19 10 DIO 4 PIO 4 PMC_11_DIO4 J2 B16 11 USB2 PMC_12_USBD J2 E20 12 PMC_28 PMC_28_DIO 13 J2 B12 13 PMC_33 TX1 GND PMC_33_DIO7_ALTB J2 C11 14 PMC_38 PMC_38 J2 B10 15 PMC_43 PMC_43_DIO11 J2 E9 16 PMC_48 VSYNC PMC_48 J2 A8 17 PMC_53 PMC_53 J2 D7 18 PMC_58 R...

Page 48: ...C_07 PMC_07_DIO1 J2 B17 6 PMC_12 PMC_12_USBD J2 E20 7 PMC_17 PMC_17_ 422_TX J2 A15 8 PMC_22 PMC_22 J2 A13 9 DIO 5 PIO 5 PMC_13_DIO5 J2 A16 10 DIO 6 PIO 6 PMC_23_DIO6 J2 E13 11 USB2 PMC_14_USBD J2 D20 12 PMC_27 PMC_27_DIO12 J2 E12 13 PMC_32 PMC_32 J2 C13 14 PMC_37 PMC_37_DIO8 J2 D11 15 PMC_42 DDC DATA PMC_42 J2 B9 16 PMC_47 PMC_47 J2 E8 17 PMC_52 PMC_52 J2 B7 18 PMC_57 PMC_57 J2 D6 19 PMC_62 GREEN ...

Page 49: ...D10 4 PMC_01 TXC PMC_01 J2 E18 5 PMC_06 TX0 GND PMC_06_DIO0_RTCV J2 E16 6 PMC_11 PMC_11_DIO4 J2 B16 7 PMC_16 PMC_16 J2 B14 8 PMC_21 PMC_21_422_RX J2 D14 9 DIO 7 PIO 7 PMC_33_DIO7_ALTB J2 C11 10 DIO 8 PIO 8 PMC_37_DIO8 J2 D11 11 A19 B19 B21 12 PMC_26 PMC_26 J2 C14 13 PMC_31 PMC_31 J2 C12 14 PMC_36 PMC_36 J2 A11 15 PMC_41 PMC_41_DIO10 J2 D10 16 PMC_46 HSYNC PMC_46 J2 B8 17 PMC_51 PMC_51 J2 E7 18 PMC...

Page 50: ...boots it executes PBIT and then calls the default applica tion If the default application returns it returns to GPM User Link E11 E12 off DSR asserted terminal connected to SCP DCP 122 serial channel 1 PBIT GPM Default Application GPM When the SCP DCP 122 boots it executes PBIT and then GPM Type rts at the GPM prompt to call the default application If the default application returns it returns to ...

Page 51: ... sign on message similar to the following SCP DCP 122 PowerPC 750FX General Purpose Monitor Version 8 0 c DY 4 Systems Inc Type for help 40000000 The last line is the initial prompt which shows the PCI base address of the card In this example the base address is 4000 0000H Cross Reference If the Status LED stays red after the power up then PBIT has found one or more problems or the selected execut...

Page 52: ...Diagnostics Results Table DRT SCP DCP 122 PowerPC 750FX General Purpose Monitor Version 8 0 Copyright 1998 to 2003 DY 4 Systems Type for help 40000000 drt DRT header address 0x5400 Binary DRT address 0x5440 Diag Sub Result Progress Fail a Fail b Fail c Fail d Pass 0 Pass 0 0 0 0 0 CpuSpaceDecode 0 Pass 0 0 0 0 0 EEPROM 0 Pass 0 0 0 0 0 RAM 0 Pass 0 0 0 0 0 Serial Port 0 Pass 0 0 0 0 0 Serial Port ...

Page 53: ...SP1160 Controllable bits Pass ISP1160 Reg Data Convergence Test Pass FPGA Timer Run Test Pass FPGA Timer INT Test Pass L2 RAM Data Test Pass L2 RAM Address Test Pass L2 Cache Miss Test Pass PCI Ven Dev ID 0x80000000 expect 0x643011AB Pass GT64260 Ethernet Reset Condition Pass GT64260 Ethernet Controllable bits Pass GT64260 Ethernet Loopback Pass GT64260 Ethernet Loopback Ext Pass BCM5221 Reset Con...

Page 54: ...Cache 0 Pass 0 0 0 0 0 PCI Ven Dev ID 0 Pass 0 0 0 0 0 GT64260Ethernet 0 Pass 0 0 0 0 0 BCM5221 0 Pass 0 0 0 0 0 ECC 0 Pass 0 0 0 0 0 MAX6634 0 Pass 0 0 0 0 0 ASCII DRT address 0x5A00 CLD complete 17 diagnostics were executed Summary Pass Pass Pass Cpu Space Decode Pass EPROM transfer Pass RAM data convergence Pass RAM address convergence 0x0003ABD4 0x0003BB70 Pass RAM misaligned transfer Pass RAM...

Page 55: ...s GT64260 ECC Polled Pass GT64260 ECC Interrupt Pass Temperature Sensor Reset Pass Temperature Sensor Controllable bits Pass Start up PBIT Binary DRT address 0x59C0 Diag Sub Result Progress Fail a Fail b Fail c Fail d Cbm 0 Pass 0 0 0 0 0 RAM 0 Pass 0 0 0 0 0 Start up PBIT ASCII DRT address 0x6F00 CLD complete 2 diagnostics were executed Summary Pass CBOOT Checksum Check Pass CBOOT Format Check Pa...

Page 56: ...board support package software See the section Overview and Installation Instructions in Chapter 1 of your BSP Software User s Manual Give careful consideration to the specific references to the SCP DCP 122 that this document makes Cross Reference Additional troubleshooting assistance is available via the Dy 4 Systems TechNet web site which includes a Troubleshooting Wizard to assist you with a nu...

Page 57: ...SCP DCP 122 GETTING STARTED MANUAL DY 4 SYSTEMS INC 4 22 812628 VERSION 1 OCTOBER 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 58: ...ions 1 5 Dimensions of the SCP DCP 122 1 5 DIO Header Pinout 4 6 Displaying the Initial Screen Message 4 16 E EIA 422 Channel 3 and Channel 4 Header Pins 4 7 EIA 422 Channel 3 Pinout 4 7 EIA 422 Channel 4 Pinout 4 7 Electrical Characteristics 1 6 Enable Booting from PABS Memory 2 7 Ethernet Connector BPK 122 000 J5 Pinout 4 5 Execution Sequence Control Jumper 2 9 F Features List 1 2 Foundation Fir...

Page 59: ...Pinout 4 4 Sign on Message Garbled 4 21 Status LED Stays Red 4 17 T The Next Step 4 21 thermal gaskets 3 2 thermal pads 3 2 thread locking compound 3 2 Transition Module 4 3 Transition Module P0 Row A Signal Mapping 4 10 Transition Module P0 Row B Signal Mapping 4 11 Transition Module P0 Row C Signal Mapping 4 12 Transition Module P0 Row D Signal Mapping 4 13 Transition Module P0 Row E Signal Mapp...

Page 60: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Reviews: