Dwyer Instruments SCT10-100 Installation And Operating Instructions Download Page 1

Bulletin PC-SCT

The  Series  SCT  Current  Transformers 

continuously  measure  the  current

consumption of pumps, fans, boilers, solar panels and chillers for use in energy

monitoring. Current or voltage outputs can be scaled using a slider switch to select

between three factory set ranges. Split core configuration allows the current transformer

to be installed on new and existing installations. Snap-on mounting bracket allows

for quick installation of replacement transformers. An optional 10 A command relay

can snap onto the current switch which eliminates the need to mount an additional

relay.

OPERATING INSTRUCTIONS

INSTALLATION

MOUNTING

1. Detach the plastic mounting bracket from the current switch housing. 

2. Using the two included screws, attach the mounting bracket to the rear of the 

electrical panel or enclosure.

3. Re-attach the current switch housing to the plastic mounting bracket.

WIRING

1. Disconnect the power to the conductor cable from the power source. 

2. Open the core using the release tab. Snap the core closed around the power 

conductor cable. Make sure that the core release tab is locked in its original 

position.

3. Wire the Series SCT as shown in the below wiring diagrams.

4. Reconnect the power conductor cable.

Specifications - Installation and Operating Instructions

Series SCT Current Transformer

SPECIFICATIONS

Amperage Range: 

30/60/120 A or 20/100/150 A (depending on model).

Continuous Operating Current: 

120 A or 150 A (depending on model).

Output: 

4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC (depending on model). Optional

relay N.O. SPST; 10 A @ 260 VAC, 5 A @ 30 VDC.

Power Requirements:

Self-powered or 24 VDC (depending on model).

Accuracy:

±2% from 10 to 100% of selected range.

Temperature Limits: 

5 to 140°F (-15 to 60°C).

Humidity Limits: 

0 to 95% non-condensing.

Response Time: 

2 seconds.

Isolation Voltage: 

600 VAC RMS.

Frequency: 

50/60 Hz.

Enclosure Rating: 

UL, V-O flammability rated, type 66 nylon. 

Agency Approvals: 

CE, RoHS, UL.

Disconnect the power supply before making electrical

connections. Contact with components carrying hazardous

voltage can cause electrical shock and may result in severe personal injury or

death.

CAUTION

       DWYER INSTRUMENTS, INC.     

Phone: 219/879-8000         www.dwyer-inst.com

             P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.          Fax: 219/872-9057             e-mail: [email protected]

                                                      

Mo

de

l S

CT

10

-1

00

An

alo

g C

urr

en

t T

rans

ducer

Re

ad

 in

str

uc

tio

ns

be

fo

re

 in

sta

lli

ng

Is

ola

tio

n

60

0 V

AC (UL)

30

0 V

AC (CE)

(8

00

) 8

72

-9

14

1

ww

w.d

wy

er-i

ns

t.co

m

3B

YE

IN

D. 

CO

NT

. C

O.

Cla

ss

 2

C2

23

44

4

1-1/16

[26.9]

2-9/16

[65.0]

43/64

[17]

SNAP ON RELAY

MOUNTING BRACKET

2-9/16

[65.0]

2-45/64

[68.6]

13/64

[5.3]

3/8

[9.6]

3-1/4

[82.4]

2-45/64

[68.6]

The Series SCT Current Transformers are intended to provide

an input to equipment under normal operating conditions.

Additional precautions must be designed into the control system where failure or

malfunction of the current transformer could lead to personal injury or property

damage to the controlled equipment or other property. Incorporate and maintain

other devices such as supervisory, alarm systems, safety or limit controls intended

to warn of or protect against failure or malfunction of the SCT.

NOTICE

Reviews: