Series PMT2 Particulate Transmitter
Specifications - Installation and Operating Instructions
Bulletin PC-PMT2-M
2X 1/2˝ NPT OR M20 ELECTRICAL ENTRY
5/8
[15.88]
“A”
1-1/2
[38.10]
4-15/16
[125.41]
3/4
[19.05]
3-29/32
[99.22]
3/4˝ NPT or 3/4˝ BSPT
ALLOW 1-1/4˝ [32]
FOR COVER REMOVAL
BOTH SIDES
4-3/8
[111.13]
2X 1/2˝ NPT OR M20 ELECTRICAL ENTRY
1˝ NPT
“A”
“B”
5-13/16
[147.64]
3-29/32
[99.22]
THREADED MOUNT
Probe
Length
A
in [mm]
3˝
5˝
10˝
15˝
20˝
30˝
36˝
3 [76.20]
5 [127.00]
10 [254.00]
15 [381.00]
20 [508.00]
30 [762.00]
36 [914.40]
1.5˝ TRI-CLAMP MOUNT
Probe
Length
A
in [mm]
B
in [mm]
3˝
5˝
10˝
15˝
20˝
30˝
36˝
3-1/2 [88.90]
5-1/2 [139.70]
10-1/2 [266.70]
15-1/2 [393.70]
20-1/2 [520.70]
30-1/2 [744.70]
36-1/2 [927.10]
1-25/32 [45.24]
3-25/32 [96.04]
8-25/32 [223.04]
13-25/32 [350.04]
18-25/32 [477.04]
28-25/32 [731.04]
34-25/32 [883.44]
1.5˝ Tri-Clamp Option Mount
3/4˝ Male NPT OR 3/4˝ Male BSPT Mount
The
SERIES PMT2
Particulate Transmitter is designed to measure particulate emission
levels from dust collector discharge. Using DC coupled electrostatic induction sensing
technology, the transmitter monitors a pA current that is generated as particulate
passes near the probe; a 4 to 20 mA signal will vary based on the particulate level. The
PMT2 offers 6 sensitivity ranges allowing the user to choose the range that will best fit
the application. The range and test selector switch can also be set to output a 4 mA or
20 mA signal to assist with set up or trouble shooting. Averaging time setting can be
used to dampen the signal if desired.
FEATURES/BENEFITS
• Simple 2-wire installation for PLC and control panels
• Non-stick PTFE coated probe to prevent false readings from moist and conductive
dusts, condensate, and dust buildup
• Remote zero calibration helps to decrease maintenance time
SPECIFICATIONS
Service:
Air and compatible gases, any type of particulate conductive or non-
conductive.
Wetted Materials:
316L SS, silicone, and PTFE.
Enclosure:
Powder coated aluminum.
Accuracy:
±5% of reading.
Particulate Size:
0.3 microns and higher.
Detection Range:
5 to 5000 pA (6 selectable range options).
Temperature Limits:
Ambient: -40 to 145°F (-40 to 63°C); Process: -40 to 248°F
(-40 to 120°C).
Pressure Limit:
30 psi (2 bar).
Output Signal:
4 to 20 mA.
Power Requirements:
12 to 28 VDC ( ).
Electrical Connection:
Two 1/2˝ female NPT electrical entries or two M20 electrical
entries (A2 suffix only).
Terminal Block:
Removable (16 to 20 AWG wire).
Process Connection:
See model chart. BSPT process connections are not UL
listed.
Probe Lengths:
See model chart.
Enclosure Rating:
UL Type 4 (IP66) ATEX/IECEx IP65.
Mounting Orientation:
Any.
Averaging Time:
1 to 360 s (10 selectable options).
Weight:
Varies with length of probe and type of mount.
Agency Approvals:
CE, cULus; ATEX Compliant: 0518 II 1 G Ex ia IIB T4 GA
(-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T
Process
≤ 120°C) / II 1 D Ex ia IIIC T120°C Da
(-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T
Process
≤ 120°C). Type Certificate No.: DEMKO
16ATEX1768 X. ATEX Standards: EN 60079-0:2012/A11:2013; EN 60079-11:2012.
IECEx Certified: Ex ia IIB T4 Ga (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T
Process
≤ 120°C) /
Ex ia IIIC T120°C Da (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T
Process
≤ 120°C).
Certificate of Conformity: IECEx UL 16.013X. IECEx Standards: IEC 60079-0: 2011;
IEC 60079-11: 2011. UL Listed Intrinsically Safe for Class I, Groups C and D; Class
II, Groups E, F and G; Class III; Class I Zone 0 AEx ia IIB T4 Ga; Class I Zone 0 Ex
ia IIB T4 Ga.
MODEL CHART
Example
PMT2 -05 -A -U2
PMT2-05-A-U2
Series
PMT2
Particulate transmitter
Probe
Length
03
05
10
15
20
30
36
3˝ probe length
5˝ probe length
10˝ probe length
15˝ probe length
20˝ probe length
30˝ probe length
36˝ probe length
Process
Connection
A
B
C
3/4˝ male NPT
1.5˝ tri-clamp kit with 1˝ male NPT
3/4˝ male BSPT
Enclosure Rating
A2
U2
ATEX and IECEx (IS)
UL (IS)*
Options
ST
M2
Stainless steel tag
Female M20 electrical entries
(female 1/2˝ NPT standard)
*Options that do not have ATEX or IECEx.
Attention: Units without the A2 suffix are not Directive 2014/34/EC (ATEX)
compliant. These Units are not intended for use in potentially hazardous
atmospheres in the EU. These unites may be CE marked for other Directives
of the EU.
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219/879-8000
Fax: 219/872-9057
www.dwyer-inst.com
e-mail: [email protected]
®