The Series CAM Compressed Air Meter

operates by the calorimetric

measuring principle to detect the standard volume flow of operating
compressed air. It is designed specifically to evaluate the current flow
rate and the current consumed quantity in compressed air systems. With
an easily programmable digital display, this unit offers a quick, accurate
readout. The Series CAM is constructed of high-grade materials and is
virtually maintenance free. 

Read the product description before installing the unit, to ensure that the
product is suitable for your application without any restrictions. Suitably
qualified personnel must perform work on compressed air equipment.
Ensure that the installation is at a standstill, before mounting compo-
nents into or removing them from compressed air equipment. Ensure
that neither people nor objects are endangered by moving parts before
commissioning / restart of the installation. Non-adherence to the operat-
ing instructions or technical data can lead to personal injury and/or dam-
age to property. In all applications, check compliance of the product
materials with the media to be measured.

Series CAM Compressed Air Meter

Specifications - Installation and Operating Instructions

Bulletin C-32

SPECIFICATIONS
Service: 

Compressed air; Air quality (see chart 1).

Wetted Materials: 

Stainless Steel (304S15), ceramics, glass passivat-

ed, PEEK, polyester, Fluoroelastomer, anodized aluminum.

Response Time: 

< 0.1 seconds.

Temperature Limit: 

32 to 140°F (0 to 60°C).

Accuracy*: 

1.41 ±3% +0.3% FV; 3.44 ±6% MV +0.6% FV.

Pressure Limit: 

232 psig (16 bar).

Humidity Limit: 

90% RH.

Power Requirements: 

19-30 DC.

Output Signal: 

Output 1: PNP Open Collector: VOUT(max)=30 VDC / 
ISINK(max)= 250mA
Output 2: 4-20mA (scalable) or PNP Open Collector.

Loop Resistance: 

500 ohms.

Current Consumption: 

<100 mA.

Electrical Connections: 

4 pin M12(Micro) Cable Connection.

Process Connections: 

1/2˝ , 1˝ and 2˝ NPT.

Display:

4-digit alphanumeric red LED

Enclosure Rating: 

IP65 (NEMA 4X).

Mounting Orientation: 

Vertical, Horizontal, Side with pipe length fac-

ing left.

Ranges: 

CAM-10: 1.4-412.0 SCFM;
CAM-20: 0.2-44.1 SCFM;
CAM-30: 1.0-132.4 SCFM.

Weight:

CAM-10: 12.5 lb;
CAM-20: 2.35 lb;
CAM-30: 4.16 lb.

Agency Approvals: 

CE.

*Ref. Chart 1 for DIN ISO 8573 Standards
e.g. 1.4.1. implies
1 = 0.01mg/m

3

oil content

4 = 15 µm particle size and 8 mg/m

3

particle density

1 = -70°C dew pt., 3 mg/m

3

residual water

Class
1
2
3
4
5
6

Max. Residual Water

Max. Residual Dust

Max. Oil
Content

Residual 
Water g/m

3

0.003
0.117
0.880
5.953
7.732
9.356

Pressure Dew
Point °C
-70
-40
-20
+3
+7
+10

Dust Concentration
mg/m

3

0.1
1
5
8
10

Particle Size
mg/µm
0.1
1
5
15
40

Oil Content
mg/m

3

0.01
0.1
1
5
25

Chart 1

3-1/32

[76.99]

E

C

A

B

4-3/8

[111.13]

3-15/16

[100.01]

M12 x 1

C

MODEL
CAM-10

CAM-20

CAM-30

A

10-53/64
[275.3]
8-9/32
[210.34]
14-49/64
[375.05]

B

18-45/64
[475.06]
11-13/16
[300.04]
18-45/64
[475.06]

C

2 NPT

1/2 NPT

1 NPT

D

5-1/4
[133.35]
3-1/32
[76.99]
3-31/64
[88.5]

E

Ø2-1/64
[Ø51.2]
Ø41/64
[Ø16.27]
Ø1-5/64
[Ø27.38]

DIMENSIONS

C-32:Magnesense bulletin  9/24/09  11:48 AM  Page 1

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for CAM Series

Page 1: ...Steel 304S15 ceramics glass passivat ed PEEK polyester Fluoroelastomer anodized aluminum Response Time 0 1 seconds Temperature Limit 32 to 140 F 0 to 60 C Accuracy 1 41 3 0 3 FV 3 44 6 MV 0 6 FV Pressure Limit 232 psig 16 bar Humidity Limit 90 RH Power Requirements 19 30 DC Output Signal Output 1 PNP Open Collector VOUT max 30 VDC ISINK max 250mA Output 2 4 20mA scalable or PNP Open Collector Loop...

Page 2: ...ng the unit on its side with the pipe length to the right This may jeopardize the accuracy Mounting To achieve the specified measurement accuracy the follow ing mounting conditions must be adhered to defined inflow outflow pipe lengths defined flow cross sectional area fixed installation depth and correct positioning of the measuring elements Integrate the pipe length so that the direction of flow...

Page 3: ...ey Functions Figure 4 Chart 2 To decrease the value cycle past the maximum value and the setting will restart from the minimum www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 4: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 5: ...able as the current count of the total izer possible data loss can be maximum 10 minutes Display indicates current measured values yellow LED s signal switching status of out puts Display unit can be temporarily changed press Set button briefly after 15 seconds unit returns to display unit set in menu point Uni Display Mode Indicates parameters and set parameter values When Mode Enter button is pu...

Page 6: ...ween SPx and rPx SPx upper value rPx lower value Scaling measuring range analog output Analog start point ASP is the measured value at which the output sig nal 4 mA is defined Analog end point AEP is the measured value at which the output signal 20 mA is defined Minimum distance between ASP and AEP 25 of final measuring range value Output signal ranges from 4 to 20 mA in set measuring range Output...