7.17 CHARGING AND IGNITION CABLES
Charging:
Voltage = 13,8 V
Max. current = 13 A
Ignition:
Wire brings ignition down to earth via STOP button
(If wire is disconnected or broken, is impossible to turn the engine off)
Current measuring
Charging and ignition cables
7.18 CURRENT MEASUREMENT TABLE ILD02
Measured Current, Voltage and Resistance
Components
Current
Voltage
Resistance
A
V
ohm
Solenoid carb.
0,3 - 0,4
12
40
Clutch-switch on
3,5
12
3-
4 20°C
Charging (max)
13
12
Steering (max)
30
12
PAL servomotors
1 (down)
2-5 (up)
12
Starter - relay coil
3
12
4,1
Moving servo
max 2
12
Engine rpm servo
6
Control panel
0,1
12
CU
2,1
12
Charging wire
Ignition wire