background image

 
 

 

RADIANT

  

 

OWNER’S MANUAL 

WARRANTY INFORMATION AND 

INSTALLATION  INSTRUCTIONS 

 
 

Gas Storage Water Heater

 

 

Models: 

135AN 170AN 

 

 

FOR ADVICE, REPAIRS AND FAST SERVICE:

 

 

1300 365 115 (AUSTRALIA)

 

0800 729 389 (NEW ZEALAND)

 

 
 

Effective for all Mains Pressure Storage Hot Water Units manufactured and sold after the 1

st

 Oct 2005 

 
 

Part No:  H3568

 

Version:  10404A 

 

Summary of Contents for Radiant 135AN

Page 1: ...CTIONS Gas Storage Water Heater Models 135AN 170AN FOR ADVICE REPAIRS AND FAST SERVICE 1300 365 115 AUSTRALIA 0800 729 389 NEW ZEALAND Effective for all Mains Pressure Storage Hot Water Units manufact...

Page 2: ...in a state of the art facility using a Quality Endorsed Company production system This is your assurance that you have purchased the highest quality water heater available one that will provide contin...

Page 3: ...y service work agreed by you the client and Dux Manufacturing Limited APPLIANCE DETAILS For future convenience would you kindly fill in the following details and retain with your original invoice for...

Page 4: ...AS1357 must be fitted in the cold water inlet supply This device must be installed after the isolating valve and set at or below 1100kPa Note Ensure that the water heater is suitable for the available...

Page 5: ...the water heater see Figure 2 Warning A separate drain line must be used for this relief valve It is not permitted to couple drain lines from relief valves into a single common drain line HOT WATER CO...

Page 6: ...ection should be used Pipe sizes should be in accordance with AG601 HOT WATER OUTLET DRAIN NOTE A COMBINED ISOLATING VALVE NON RETURN VALVE LINE STRAINER MAY BE USED UNION CONNECTION NON RETURN VALVE...

Page 7: ...7...

Page 8: ...nium anode should be fitted Please consult our Service Department for advise if required TESTING THE WATER HEATER Test operation by lighting the water heater see Operating Instructions Check that the...

Page 9: ...be checked for adequate performance or replaced at intervals not exceeding 5 years or less in areas where there is a high incidence of water deposits The lever on the relief valve must be pulled to o...

Page 10: ...ver upwards and away from the water heater The unit is fitted with a thermostat that incorporates a Thermal Overload Safety Cut Out In the event of thermostat failure the Safety Cut Out will automatic...

Page 11: ...Figure 3 Fitting of Plumbing Insulation Caps 11...

Page 12: ...OPERATING INSTRUCTIONS Figure 4 Lighting Instructions 12...

Page 13: ...ng too much water See Pressure Temperature Relief Valve Running Do you have the correct size water heater for your requirements Sizing details are available from your Dux supplier Is one outlet especi...

Page 14: ...following Replace the pressure temperature relief valve Replace the anode Clean and service the gas burner and pilot Flush the cylinder COMMISSIONING ADJUSTMENTS a Main Gas Pressure Regulator Adjustme...

Page 15: ...the front ii Remove plastic cap covering the NO PR screw iii Turn PILOT ADJ screw fully anti clockwise iv Put pressure governor fully out of service by screwing the NO PR fully home in a clockwise di...

Page 16: ...arest approved Dux agent or Dux office to the owners home Under this replacement guarantee the transport installation and labour costs of delivering the replacement hot water unit and removing and rep...

Page 17: ...ll not be liable for any loss or damage to furniture carpets walls foundations or any other consequential loss of any kind caused by a defect in the hot water unit or any component 11 Any claim under...

Page 18: ...SPECIFICATIONS Figure 4 Dimensions of Unit Model No Mass DIMENSIONS mm Nominal kg A B C Baffle Length Capacity L Unitrol EuroSIT 135AN 76 1603 1327 336 315 1125 135 170AN 87 1898 1622 336 315 1236 17...

Reviews: