25
Oxford Direct Vent / Natural Vent Gas Heater
3-90-20306762
1.
STOP!
Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. Turn the ON/OFF switch to “OFF” position, set the
remote to OFF or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to “OFF”.
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This heater has a pilot which must be lit manually. When
lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the heater area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any fireplace
•
Do not touch any electric switch
•
Do not use any phone in your building
•
Immediately call your gas supplier from a
neighbor’s phone.
Follow the gas supplier’s instructions.
To Turn Off Gas To Heater
Lighting and Operating Instructions
1. Turn the ON/OFF switch to Off position or set the
thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service is to
be performed.
Lighting Instructions
SIT NOVA
PIL
OT
ON
OFF
ON
PILOT
O
FF
OFF
FP1067
lighting instruction
knobs
3/9/01 djt
5
4
3
2
1
O
FF
P
ilo
t
3/8" - 1/2"
FP1068
Lighting instructions
Pilots
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
•
If you cannot reach your gas supplier, call the
Fire Department
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it, call a qualified service
technician. Applying force or any attempted repair may
result in a fire or explosion.
D. Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect
the heater and to replace any part of the control system
and any gas control which has been under water.
• If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
• If after several tries, the pilot will not stay lit, turn
the gas control knob to “OFF” and call your service
technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. Turn the ON/OFF switch to “ON” position or set
thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
10. Push the control knob all the way in and hold. Immediately
light the pilot by repeatedly depressing the piezo spark
ignitor until a flame appears. Continue to hold the
control knob in for about one (1) minute after the pilot
is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
6. Remove glass door before lighting pilot. (See Glass
Frame Removal section).
7. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow “B” in the safety information above. If you do not
smell gas, go to the next step.
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to
“PILOT”.
3. Open control access panel.
4. Push in gas control knob slightly and turn clockwise
to “OFF”. Do not force.
5. Close control access panel.