19
Oxford Direct Vent / Natural Vent Gas Heater
3-90-20306762
ST767
DW
attach draft hood
5/15/03 djt
CEMENT
Figure 33
- Install draft hood adapter.
Install the Log Set
1. Remove the logs from their packaging, and inspect
each piece for damage.
DO NOT INSTALL DAMAGED
LOGS.
2. Install the rear log centering it side to side on the sheet
metal shelf at the back of the firebox. (Figure 34) The log
will touch both sides and the back wall of the firebox.
3. Install the right log by engaging hole on bottom with pin
on the rear log. (Figure 34) Then set right bottom side on
the burner so the edge of the log touches the right side
of the firebox. The right log does not use the locator pins
on the burner to stay in place.
4. Install the left log by engaging hole on bottom with pin
on rear log. (Figure 34) Then set left bottom side on the
burner so the edge of the log touches the left side of the
firebox.
5. Loosely sprinkle the lava rocks directly on top of the
burner in front of and between the decorative grate and
the right and left logs. Use the lava rock to cover brackets
on the burner. (Figure 34)
LG141
Stardance
Install logs 1
12/11/00 djt
Left Log
Right Log
Rear Log
Decorative Grate
Figure 34
- Install the back, left and right logs.
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox for
the type of fuel to be used. The Oxford may be converted
from one gas to another using the appropriate Fuel
Conversion Kit.
This appliance should only be connected by a
qualified gas technician. Test to confirm manifold
pressures as specified below.
The heater and its individual shutoff valve must be
disconnected from the gas supply piping during any
pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
The heater must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressure equal to or
less than 1/2 psig.
There must be a gas shutoff between the stove and
the supply.
In order to connect Natural Gas, use a fitting with
3/8” NPT nipple on the valve side and 1/2” natural
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 3.5” and minimum inlet supply
for adjustment of 5.5” w.c.
In order to connect Propane, use a fitting with 3/8”
NPT nipple on the valve side and 1/2” propane
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 10.0” and minimum inlet supply
for adjustment of 11.0” w.c.
CAUTION
!
Attach the first section of venting to the draft hood.
Depending on the length of the individual venting sections
and the lengths of the decorative pipe (if installed), you may
need to slip the decorative pipe over the venting sections
before attaching upper sections to lower ones. The sections
of decorative pipe should be oriented with their seams (if
any) toward the wall; sections usually do not need to be
fastened at each joint, other than slip sections. If the layout
includes a slip section, this should be the last section of
pipe visible in the room, at the ceiling. Complete the venting
according to the vent maker’s instructions.