General Venting Information - Termination Location

Canadian Installation

1

US Installations

2

A

Clearance above grade, verenda, porch, deck or 

balcony

12" (30cm)

12" (30cm)

B

Clearance to a window or door that may be 

opened

6" (15cm) for appliance

< 10,000 Btuh (3kW). 12" (30cm) for appliances 

> 10,000 Btuh (3kW) and < 100,000 Btuh 

(30kW), 36" (91cm) for appliances > 100,00 

Btuh (30kW) appliances > 50,000 Btuh (15kW)

6" (15cm) for appliances < 10,000 Btuh (3kW), 

9" (23cm) for appliances > 10,000 Btuh (3kW) 

and < 50,000 Btuh (15kW), 12" (30cm) for 

appliances > 50,000 Btuh (15kW)

C

Clearance to permanently closed window

12" (305mm) recommend to prevent window 

condensation.

12" (305mm) recommend to prevent window 

condensation.

D

Vertical  clearance  to  ventilated  soffit  located 

above the terminal within a horizontal distance 

of 2 feet (610mm) from the center line of the 

terminal

18" (458mm)

18" (458mm)

E

Clearance to unventilated soffit

12" (305mm)

12" (305mm)

F

Clearance to outside corner

see next page

see next page

G

Clearance to inside corner (see next page)

see next page

see next page

H

Clearance to each inside of center line extended 

above meter/regulator assembly

3' (91cm) within a height if 15' (5m) above the 

meter/regulator assembly

3' (91cm) within a height if 15' (5m) above the 

meter/regulator assembly

I

Clearance to service regulator vent outlet

3' (91cm)

3' (91cm)

J

Clearance to non-mechanical air supply inlet to 

building or the combustion air inlet to any other 

appliances

6” (15cm) for appliances < 10,000 Btuh (3kW), 

12” (30cm) for appliances > 10,000 Btuh (3kW) 

and < 100,000 Btuh (30kW), 36” (91cm) for 

appliances > 100,000 Btuh (30kW)

6” (15cm) for appliances < 10,000 Btuh (3kW), 

9” (23cm) for appliances > 10,000 Btuh (3kW) 

and < 50,000 Btuh (15kW), 12” (30cm) for 

appliances > 50,000 Btuh (15kW)

K

Clearance to a mechanical air supply inlet

6' (1.83m)

3’ (91cm) above if within 10’ (3m) horizontally

L

Clearance above paved sidewalk or paved 

driveway located on public property

7’ (2.13m)†

7’ (2.13m)†

M

Clearance under veranda, porch, deck or balcony

12" (30cm)*

12" (30cm)*

N

Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof  surface, and any other 

obstruction within a horizontal distance of 18” (450mm).

 1 In accordance with the current CSA-B149 Installation Codes
 2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
 † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and    

 

serves both dwellings

 * only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: 

NOTE:

1. Local codes or regulations may require different clearances.

2. The special venting system used on Direct Vent appliances are certified as part of the appliance, with clearances tested and approved by the listing 

agency.
3. Hearth and Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet 

these requirements.

V

V

V

V

V

V

V

X

X

X

D

E

B

B

B

C

B

M

B

A

J

K

F

L

VENT TERMINATION 

AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

H

I

Fixed

Closed

Operable

Operable

Fixed

Closed

V

B

CFM145a
DV Termin Location
5/01/01 Rev. 12/05/01 
sta

INSIDE

CORNER DETAIL

V

A

G

N

N

CFM145a

Figure 9

 - Vent termination clearances.

Summary of Contents for OXDV30NVSB

Page 1: ...ilding immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and ser...

Page 2: ...the Optional Fan 13 Venting System Assembly Direct Vent 14 Install Vent Adapter Pipe HHT Vent Components 14 Install Vent Adapter Pipe Dura Vent Components 15 Side Wall Termination Assembly 15 Vent Te...

Page 3: ...rom the room for combustion and vent the exhaust vertically through the roof to the atmosphere This appliance is approved for bedroom installations in the U S and Canada This appliance may be installe...

Page 4: ...inal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIO...

Page 5: ...dimensions Attention The Oxford stove is shipped from the factory as a Direct Vent Gas Heater This heater may be converted into a Natural Vent unit in the field If a Natural Vent heater is desired th...

Page 6: ...ir spaces to nearby combustibles to prevent fire hazard Do not fill air spaces with insulation All venting components must maintain a 1 25 mm clearance to combustible materials Maintain a 6 150 mm cle...

Page 7: ...terline from Floor ST1121 wall thimble A Effective Minimum A Wall Thimble 571 2 1461 mm HHT Pipe Centerline 531 2 1359 mm Simpson DuraVent Pipe Figure 5 Minimum wall thimble centerline Hearth Requirem...

Page 8: ...rough 11 Approved vent systems must terminate above and including the heavy line in Figure 7 Two 45 elbows may be substituted for each single 90 elbow With a rise between 2 5 one 90 or two 45 elbows m...

Page 9: ...en planning the installation consider the location of the vent terminal and clearances Some of the most common clearances to keep in mind are shown in Figure 10 Important All vent clearances must be m...

Page 10: ...en sheds fences decks or utility buildings within 24 from the front of the termination hood Do not locate termination hood where excessive snow or ice build up may occur Be sure to check vent terminat...

Page 11: ...uh 3kW and 100 000 Btuh 30kW 36 91cm for appliances 100 000 Btuh 30kW 6 15cm for appliances 10 000 Btuh 3kW 9 23cm for appliances 10 000 Btuh 3kW and 50 000 Btuh 15kW 12 30cm for appliances 50 000 Btu...

Page 12: ...rictor plate supplied with the stove is not used Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors G Combustible 6...

Page 13: ...stat assembly to the snapstat bracket with two sheet metal screws 2 Figure 14 Attach the snapstat bracket to the stove with a hex head bolt passing through the bracket and into the stove base 3 Figure...

Page 14: ...e with 12 x 1 2 sheet metal screw 5 Install the Outer Adapter Pipe Apply a 1 4 bead of cement around the inside wall of the pipe about 1 from the end Insert the pipe over the stove flue collar keeping...

Page 15: ...sure the wall thickness and cut the wall sleeve sections to proper length MAXIMUM 12 Assemble the sleeve with the 8 sheet metal screws supplied Attach the firestop plate to the sleeve end with the hol...

Page 16: ...holes through each joint and fasten with sheet metal screws 6 Seal and install the elbow using 3 sheet metal screws at each joint 7 Measure and cut if needed the appropriate length of pipe section ne...

Page 17: ...ws and Anchors Waterproof Seal Around Pipe Figure 29 Use extension brackets to mount snorkel against recessed wall Vertical Through the Roof Vent Assembly Note that all vertically terminated installat...

Page 18: ...ply a bead of sealant around bottom end of inner starter pipe found in bag with logset and attach to stove Apply a bead of sealant around top of inner starter pipe and install the FSDHAGSLP Draft Hood...

Page 19: ...Kit This appliance should only be connected by a qualified gas technician Test to confirm manifold pressures as specified below The heater and its individual shutoff valve must be disconnected from t...

Page 20: ...pull to the right to clear the injectors on the left hand side 8 The air shutter is located on the bottom of the burner to the left Figure 37 Unfasten the two nuts holding the shutter in place ST350 J...

Page 21: ...00 djt Existing Holes Switch Assembly Screws Figure 41 Attach switch assembly to rear shroud PILOT ADJ TP TH TPTH ST228 attach switch wires to valve 12 99 Figure 42 Attach switch wires to valve 9 Ref...

Page 22: ...ten in place with the 3 8 locking nut provided Figure 43 The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body Positio...

Page 23: ...reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals 20306543 CERTIFIED SAFETY BARRI...

Page 24: ...lame height Turn clockwise to increase flame height HV102 Honeywell hi lo knob 4 5 99 djt Figure 47 Flame adjustment knob for Honeywell valve CO105c Pilot flame 4 10 00 djt LG142 Stardance Install log...

Page 25: ...y your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Applying force or any attem...

Page 26: ...s not stay on replace the gas valve NOTE An interrupter block not supplied must be used to conduct this test 3 Pilot burning no gas to main burner A Wall switch or wires defective Check wall switch an...

Page 27: ...ve 1 Using TORX T20 bit remove and discard the three 3 pressure regulator mounting screws A pressure regulator tower B and the spring and diaphragm assembly C Figure 51 2 Insure the rubber gasket D is...

Page 28: ...emove pilot orifice with needle nose pliers Figure 56 NOTE Use a wrench to hold pilot tube in place while removing the orifice Install the conversion orifice Reinstall pilot hood and tighten until mar...

Page 29: ...ith a wire brush and be sure to cover the logs burner and valve assembly glass and frame assembly Apply the paint sparingly two light coats of paint will give better results than a single heavy coat C...

Page 30: ...be checked to confirm that they are unblocked and in good condition Check the Gas Flame Regularly To ensure that the stove is operating properly check the flames periodically to confirms they match F...

Page 31: ...at circuit NOTE IFANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE SF 2 200 WIRE OR ITS EQUIVALENT Thermocouple Safety Limit Switch Valve ST665 Sa...

Page 32: ...iption Oxford 1 Gas Log Assembly SDV30 20003458 1a Rear Log 20003459 1b Right Log 20003460 1c Left Log 20003461 2 Small Lava Rock Package 57897 3 Top 30001925 4 Front 30001928 5 Door 30001929 6 End Rt...

Page 33: ...andle Assy E V WSI 5004241 24 Handle Damper Maple Wood Blk 1600664 25 Switch ON OFF RN RP Models 30000874 26 Wiring Harness FSDV32 RN JDV 10002582 27 Right Log Bracket 20002166 28 Left Log Bracket 200...

Page 34: ...ications 115 Volt 60Hz 75 Amps Maintenance The fan itself does not require regular maintenance however periodic cleaning of the fan and the surrounding area is required Installation Refer to Page 14 f...

Page 35: ...uthorized Dealer in home travel fees or service charges for in home repair work It is the dealers option whether the repair work will be done in the customer s home or in the dealer s shop If upon ins...

Page 36: ...Draft Hood Adapter Flex Venting Components SLP HSFTK Horizontal Vent Termination Kit includes adj Termination Cap 1 firestop 42 Flex and adapters Pipe SLP 20TPM 20 Termination pipe multi pack of 6 SL...

Page 37: ...to slide over pipe can be cut to length multi pack of 6 SLP12AM 2 12 51 305mm slip section to slide over pipe can be cut to length multi pack of 6 SLP4M 4 102mm pipe length multi pack of 6 SLP6M 6 152...

Page 38: ...s la brochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 352 Mountain House Road Halifax PA 17032 www vermontcastings com Efficiency Ratings Model EnerGuid...

Reviews: