DutchWest DutchWest CDW247001 Owner'S Manual Download Page 14

14

CDW247001

30004577

������
��������������
�����

TOUJOURS FOURNIR UNE SOURCE D’AIR FRAIS 
DANS  LA  PIÈCE  OÙ  L’UNITÉ  EST  INSTALLÉE. 
L’ÉCHEC  POUR  FAIRE  SI  PEUT  AVOIR  POUR 
RÉSULTAT  DE  LA  FAMINE  D’AIR  D’AUTRE  CAR-
BURANT BRÛLE DES APPAREILS ET LE DÉVEL-
OPPEMENT POSSIBLE DE CONDITIONS HASAR-
DEUSES.

L’APPAREIL  DEVIENT  TRÈS  CHAUD  EN  UTILI-
SATION.  DE  GRAVES  BRÛLURES  PEUVENT 
ÊTRE CAUSÉES À SON CONTACT. IL FAUT ÊTRE 
PARTICULIÉREMENT  PRUDENT  EN  PRÉSENCE 
D’ENFANTS.

Soufflerie Facultative :

 Modèle S31105

120 V, Frequ 60 Hz, 0.75 Amps 2900 RPM

DANGER :

 Risque de secousse électrique, débran-

chez avant de procéder a l’entretien.

Important :

 Pour une meilleure performance de cet 

appareil au “allumage bas” le ventilateur doit fonction-
ner a vitesse bas.

Installation

1.  Retirez tous les composants placés à l’intérieur du 

poêle.

2.  Choisissez l’emplacement pour le poêle. Cet appar-

eil ne doit pas être installé en-deçà des distances de 
dégagement minimales à respecter par rapport aux 
matières combustibles (à la page 24). Le poêle doit 
être installé sur une surface non combustible. (Fig. 
1)

3.  Si des matériaux non combustibles ont été installés 

sur les murs, obtenez du fabricant de ces matériaux 
ou du bureau local d’inspection des bâtiments les 
distances de dégagement minimales à respecter.

4.  Installez des briques réfractaires. (Fig. 2)
5.  Installez le tuyau à fumée À L’INTÉRIEUR du collier 

de la cheminée, sur le dessus du poêle poru relier le 
poêle et la cheminée.

6.  N’UTILISEZ PAS de chenets dans votre poêle.

Si vous ne respectez pas les distances de dégage-
ment minimales requises et ne disposez pas sur 
une surface non combustible, votre installation 
pourrait présenter des problèmes de sécurité.

2 Briques complètes

Déflecteur

Assurez vous de bien installer 
deux briques entieres dans le 
déflecteur tel que montre ci des-
sus (S16040)

ST1019

Figure 2
Installez des briques

8”

8”

8”

*16”
**18”

A

B

D

E

C

F

C

F

ST1005
CDW244
clearances
9/08

Figure 1
Dégagement entre le poêle et les matériaux combustibles

Mur arrière

Mur latéral

Mur latéral

Mur arrière

Le poêle doit être installé sur un plancher inflammable, équivalent à 
9,5 mm) 3/8 po “millboard”. Protecteur pour le plancher faut être une 
minimal R evaluer de .893. Informez vous auprès de l’inspecteur en 
bâtiment de votre localité pour determiner si un permis est requis.

Tuyau de cheminée 6 po

   

F        G

 

d’un poêle avec

 

 

 

 

 

 

 

   

 

raccord de

 

10

¹⁄₂

  10

¹⁄₂

  10

¹⁄₂

 

19 

11

¹⁄₂

 

19 

54   

 

cheminée à 

(267)  (267)  (267)  (483)  (292)  (483)  (1372)

 

  parloi simple

 

d’un poêle avec 

 

 

 

 

 

 

   

  raccord de

 

2

¹⁄₂

 

2

¹⁄₂

 

10

¹⁄₂

 

5

¹⁄₂

 

10 

54   

 

cheminée à

 

(84)  (127)  (64)  (267)  (140)  (254)  (1372) 

 

parloi double

Summary of Contents for DutchWest CDW247001

Page 1: ...EMENTS IN YOUR AREA This stove is listed by OMNI Test Laboratories of Port land Oregon to meet UL1482 for the US and ULC 627 for Canada Do Not Discard This Manual Retain for Future Use 6 Flue required...

Page 2: ...r indicates excessive draft Inad equate draft may cause back puf ng into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance and chim ney conn...

Page 3: ...unsafe installation 6 Flue Required A B C D E F G Single wall 10 10 10 19 11 19 54 Connector 267 267 267 483 292 483 1372 Double wall 2 5 2 10 5 10 54 Connector 84 127 64 267 140 254 1372 Baf e Assem...

Page 4: ...METHODS OF INSTALLATION 1 This appliance requires a masonry or pre manufac tured chimney listed to ULC S629 Canada and UL 103HT US sized correctly 2 If a masonry chimney is used it is advisable to ha...

Page 5: ...m The solution would be to reduce the area by relining it with an approved chimney liner or replacing the chimney Regulations specify the chimney must extend 2 610 mm above a 10 3 m radius of the top...

Page 6: ...tly ignited While a basic rule of thumb is closed low 1 2 way medium and fully open high refer to the Inlet Air Control Settings chart 9 When refueling adjust air control to the fully open position Wh...

Page 7: ...wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be depos ited within the system WARNING Things to remember in case of chim ney re 1 Close draft control 2 Call the...

Page 8: ...ry seasoned wood will deposit creosote on the inside of your stove and along the inside of your chimney 3 What does dry seasoned wood mean and what is considered hardwood Wood that has been dried for...

Page 9: ...t fteen to forty minutes being careful not to over re If any part of the chimney or parts of the stove start to glow you are over r ing the stove Where possible install a tempera ture gauge on the chi...

Page 10: ...sembly 1 90000082 2 3 Glass and Gasket 1 S31117 3 1 8 Glass Gasket 4 0 S15001 4 5 8 Door Gasket 4 5 S15011 5 Spring Handle 1 90000069 6 Air Control Spring Handle 1 90000070 7 Glass Clip 6 S37034 8 Scr...

Page 11: ...SC supplier or MHSC Customer Service Department 10 MHSC will not be responsible for Down drafts or spillage caused by environmental conditions such as near by trees buildings rooftops hills mountains...

Page 12: ...n pour les po les bois x es par l agence Am ricaine de protection de l environnement Dans des conditions sp cifiques ce po le d gage entre 11 492 et 18 920 BTU l heure AVIS DE S CURIT Si le po le n es...

Page 13: ...E DES INCENDIES 10 NE TRAFIQUEZ PAS la commande d admission d air au del de son r glage normal Fonctionnement pr caution Pourquoi un conduit d vacuation de 6 po 152 mm Le tirage est le d placement de...

Page 14: ...ureau local d inspection des b timents les distances de d gagement minimales respecter 4 Installez des briques r fractaires Fig 2 5 Installez le tuyau fum e L INT RIEUR du collier de la chemin e sur l...

Page 15: ...er des refoulements de fum e 7 Il n est pas n cessaire d avoir de r gulateur de tirage Retirez la plaque de r gulation du tirage install dans la chemin e ou fixez la en position OUVERTE Maisons mobile...

Page 16: ...du sol de l emplacement du po le et de l installation de l admission d air de combus tion provenant de l ext rieur Mise en garde L int grit structurale du plancher de la maison mobile des murs du plaf...

Page 17: ...pi 610 mm de plus que tout autre objet qui se trouve dans un rayon de 10 pi 3 0 m du dessus de la chemi n e endroit bien ventil Et le bois doit tre gard distance de tout combustible Ne br lez pas du...

Page 18: ...s que l appareil est bien refroidi 2 Enlevez les vis et la bordure de fixation voir sch ma des pi ces 3 Retirez la vitre 4 Enlevez le vieux joint et nettoyez la vitre 5 Installez le joint neuf en comm...

Page 19: ...ez la porte et laissez s cher la colle durant trois quatre heures avant d utiliser l appareil 3 NE BR LEZ QUE DU BOIS SEC vitez le bois vert Le bois sec doit avoir s ch pendant au moins un an 4 Un pet...

Page 20: ...s la commande d admission d air est r gl e un niveau bas plus la combustion de votre bois durera longtemps 2 Quel est le meilleur type de bois qu on peut utiliser dans le po le Vous devriez utiliser d...

Page 21: ...te poru laisser entrer l air dans la maison b Conditions environnementales Les grands arbres les d pressions comme une vall e les grands di ces ou structures adjacents votre maison et l intensit du ve...

Page 22: ...on d air 1 90000070 7 Ferrure pour la vitre 6 S37018 8 Vis 6 S11086 9 Hinge Pin 2 S11005 10 Push Nut 2 S11090 11 Brique 9 x 4 x 1 10 S16040 12 Brique 6 x 4 x 1 1 S16249 MHSC se r serve le droit de fai...

Page 23: ...nes ou une conception de chemin e inad quate de la ventilation inad quate des d volements excessifs ou de la pression d air n gative caus s par des syst mes m caniques tels que les foyers les s cheuse...

Page 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: