User Guide
Zigbee TYPE
Welcome
Thank you for your purchase.
/ŶƚŚĞďŽdžLJŽƵǁŝůůĮŶĚ
Thermostat
Screws
User Guide
1pc
4pc
2pc
QC Passed
1pc
SYSTEM TYPE
FEATURES
On Appearance
2. 4.8 inch large colorful display creates your colorful life.
4. Amazing silver frame opens your modern life.
7. Wall mounted
and Italy etc,.
10. 12 terminals are available for many systems.
2. 1
℉
℃
accuracy keeps temperature within the level you set.
3.
℃
or
℉
choice.
4. 7 days four periods programmable.
5. Temporary programmable.
6. Holiday mode.
8. No limit to add thermostats in App.
9. Support Smart Scene.
10. Support to make two stage grouops.
11. Support device sharing.
12. Weather, UV index, humidity display help you decide what to wear today.
DSHT-040 Room Thermostat
Your new thermostat will provide uniform and comfortable temperature
control throughout every room in your peoperty. We bring together technology,
reliable product combined with sleek, contemporary design. Please read this
1. Warm air, hot water, high e
ĸĐŝĞŶĐLJĨƵƌŶĂĐĞƐ͕ŚĞ
at pumps, steam, gravity.
2. Heat only--including power to open and close zone valves, and normally
open zone valves.
3. Heat only with fan.
4. Cool only.
TECHNICAL DATA
Power Supply: 24VDC/AC ±10%
Sensor: NTC3950, 10K
Set Temp. Range: 42-122
℉
(5~50
℃
)
Accuracy: ±1
℉
Display Temp. Range: 41~210
℉
(5~99
℃
)
Ambient Temp: 32~113
℉
(0~45
℃
)
Ambient Humidity: 5~95%RH(Non Condensing)
Storage Temp: 23~113
℉
(-5~45
℃
)
DIMENSION
Unit: mm (inch)
Timing Error: <1%
Shell Material: PC+ABS(Fireproof)
Hole Distance of 86±3mm (USA and Italy etc,.)
Wire Terminals: Wire 2×1.5mm2 or 1×2.5mm2
INSTALLATION
For wiring , please refer to another page.
CAUTION
Electrical Shock or Equipment Damage Hazard. Can shock individuals or
short equipment circuitry.
HOME SCREEN QUICK REFERENCE
@OMHKKͧ'6SUJKͨ
@OMHKKͧ+@SUJKͨ
';>.KGZ
YZ9ZGMK.KGZ
YZ9ZGMK)UUR
,GT
=OTJYVKKJ
=KGZNKX
6KXOUJY
3UTJG_ZU9[TJG_
+^ZKXTGRYKTYUX
;RZXG\OURKZOTZKTYOZ_
5[ZJUUX.[SOJOZ_
*U]T([ZZUT
;V([ZZUT
)RUIQ
6KXSGTKTZ.URJ:KSVUXGX_
.URJ;YOTM9INKJ[RK.URJ;TZORNUROJG_
'[ZU)UUR.3+8
6U]KXUTULL
:OSK*OYVRG_
9KZZKSV
3KT[
8UUS:KSV
,GT5T'[ZU
9_YZKSSUJK
2UIQ;TRUIQ
,ORZKX8KSOTJKX
COOL — Thermostat controls the cooling system.
EMER — Emergency heat cycles to maintain temperature. Compressor is
locked out (used only for 2H/1C or 3H/2C heat pump systems) and auxiliary
heat turns on as second stage if needed.
:
Press to set the Permanent Hold, Temporary Hold, Using Schedule
Permanent Hold - Manual.
In this mode, press / to set
temperature by manual.
Temporary Hold.
During Using Schedule or in this mode, press /
next scheduled period.
Using Schedule
. 7 days a week, four periods programmable daily.
Holiday Mode.
of days.
Press
Touch the icon / to set your minute.
Then press
,
;
Touch the icon / to
set your hour.
Then press
set your week.
How to adjust your schedule?
Press the icon then use the / arrows to set the temp. for the 1st
period. Repeat this process for periods 2-4.
Get Up — Period when you awaken and want your home at a
comfortable temperature.
Go Out — Period when you are away from home and want an
energy-saving temperature.
Go Home — Period when you return home and want your home
back to a comfortable temperature.
Sleep — Period when you are asleep and want an energy saving
temperature.
Schedule Period
Time
Setpoints
Heat
Cool
Get Up
6:00 AM
72
̧
(22
ć
)
72
̧
(22
ć
)
Go Out
8:00 AM
72
̧
(22
ć
)
72
̧
(22
ć
)
Go Home
11:30 AM
72
̧
(22
ć
)
72
̧
(22
ć
)
Sleep
01:30 AM
72
̧
(22
ć
)
72
̧
(22
ć
)
How to adjust your holiday?
Press
displays and
days
ŇĂƐŚŽŶ
the screen then click / arrows to set the days of holiday .
tŚĞŶƚŚĞŇĂƐŚŝŶŐŽĨĚĂLJƐƐƚŽƉƐ͕LJŽƵĐĂŶƉƌĞƐƐͬĂƌƌŽǁƐ
to set the temp. Holiday mode will be valid immediately.
:
Then press to change the di
ī
erent items. You can press /
Fact
4.
TJ9ZGMK.KGZ
TJ9ZGMK)UUR
2cm (0.787 inch).
increase the
the temperature sensing accuracy.
130.0 (5.12)
103.8 (4.09)
20.9 (0.82)
17.2 (0.68)
104.5 (4.11)
82.3 ± 3
(
5.12 ± 0.12
)
60.0 ± 3
(
2.36 ± 0.12
)
90.0
︵
3.54)
63.8 (2.51)
3. Installer must be a trained, experienced service technician.
BEFORE WIRING AND INSTALLING
9KZ:KSV
User Setup
Number
Function
Setting and options
Default
,GT54';:5
,GT';:5! ,GT54
:KSVKXGZ[XK)GROHXGZOUT
q,ZUq,q)ZUq)
ȯ
)USVXKYYUXJKRG_ZOSKLUXNKGZ
V[SV
SOT[ZKY
)NGTMKU\KX<GR\Kȍ5(:KXSOTGR
+TKXMO`KJOT.KGZOTMUX)UUROTM
.KGZ6[SVY5TR_5TR_YNU]TOL
NKGZV[SVY_YZKSOYINUYKT
IUUROTM5(#
NKGZOTM5(#!
IUUROTM5(#
NKGZOTM5(#!
3OTOS[SYKZZOTMZKSVKXGZ[XK
q,ZUq,ZUq)
ȯȭ
3G^OS[SYKZZOTMZKSVKXGZ[XK
q,ZUq,ZUq
ȯȭ
:OSKJOYVRG_
NU[XIRUIQ!
NU[XIRUIQ
*KGJHGTJZKSVKXGZ[XKOT'[ZU
SUJKLUXNKGZV[SV.KGZOTMGTJ
IUUROTMYKZVUOTZYIGTHKYKZTU
IRUYKXZNGTINUYKT\GR[K9NU]T
UTR_OLG[ZUSGZOIINGTMKU\KXOY
YKRKIZKJ
q)ZUq)q,ZUq,
ȭ
,ORZKXIRKGTOTMXKSOTJKX
SUTZNY
'
9ZGTJH_YIXKKTHXOMNZTKYY
(
:KSVKXGZ[XK/TJOIGZOUT
9IGRK
ȭJOYVRG_! ȯJOYVRG_
)
*KGJ`UTKZKSVKXGZ[XKLUXZ[XTOTM
UTULLRUGJ
q)ZUq)q,ZUq,
ȭ
*
,GT)UTZXUROT.KGZOTM
=OZNU[ZIUTZXUR!
=OZNIUTZXUR
+
)NGTMKZNKY_YZKSULNKGZV[SV
GTJGOXIUTJOZOUTOTM
.KGZV[SV
'OXIUTJOZOUTOTM
Your thermostat can be mounted horizontally on the wall or on a 4 in. x 2 in.
(101.6 mm x 50.8 mm) wiring box.
I
ŽŶ͛ƚŝŶƐƚĂůůLJŽƵƌƚŚĞƌŵŽƐƚĂƚǁŚĞƌĞŝƚĐŽƵůĚďĞĂīĞĐƚĞĚďLJ͗
— Hot or cold air from ducts.
— Radiant heat from sun or appliances.
— Concealed pipes and chimneys.
— Unheated (uncooled) areas.
Fig 1
Step 3. Complete the wiring according to the wiring diagram and select the appropriate
Fig 2
Fig
Fig 2
g 2
2
ig
g 2
g 2
F
F
Fig
Fig 2
thermostat display panel. See Fig 3.
Fig 2
Fig 3
F
F
ig
g 2
F
F
ig
Step 1. Keep the electricity o
ī
.
See Fig 4.
Fig 4
Steps
OPERATION
ƚŽƚƵƌŶƚŚĞƚŚĞƌŵŽƐƚĂƚŽŶͬŽī͘
Press
1. Power On/
Žī͗
Press to select the mode AUTO, COOL,
HEAT, OFF, EMER
NO
NO
NO
YES
5FEET
(1.5METERS)