4.6.6 Setting the reference light barrier sewing axis
Proper setting
To reference the needle bar, position the machine at top dead center.
1.
Switch off and on the machine again.
2.
Reference the machine and check that the needle bar is at top dead
center.
Fig. 40: Setting the reference light barrier
Cover
• Arm cover
To set the reference light barrier:
1.
Switch off and on the machine again.
2.
Tap on
Multitest
.
3.
Input the password (25483).
4.
Tap on
Multitest
>
Eingänge/Ausgänge testen
(Test inputs/outputs)
.
5.
Turn the needle bar to top dead center and insert the 3 mm end of the
locking peg to peg the arm shaft crank to position 2.
6.
Loosen the threaded pin (1).
WARNING
Risk of injury from sharp and moving parts!
Puncture or crushing possible.
Check and set the reference light barrier only with
very great care.
(1)
- Threaded pin
(2)
- Take-up lever disk
(3)
- Locking peg
①
②
③
Summary of Contents for 911-211
Page 1: ...Service Instructions 911 211...
Page 6: ...Table of Contents 5 Service Instructions 911 211 02 0 10 2016...
Page 10: ...About these instructions 9 Service Instructions 911 211 02 0 10 2016...
Page 90: ...Sewing unit 89 Service Instructions 911 211 02 0 10 2016...
Page 146: ...Creating programs with DA CAD 5000 145 Service Instructions 911 211 02 0 10 2016...
Page 158: ...Decommissioning 157 Service Instructions 911 211 02 0 10 2016...
Page 160: ...Disposal 159 Service Instructions 911 211 02 0 10 2016...
Page 170: ...Technical data 169 Service Instructions 911 211 02 0 10 2016...
Page 195: ...Appendix Service Instructions 911 211 02 0 10 2016 194...
Page 197: ...Appendix Service Instructions 911 211 02 0 10 2016 196 13 3 Pneumatic diagram...
Page 199: ......