Programming
121
Service Instructions 911-211 - 02.0 - 10/2016
6.17.2 Changing the parameters of a seam program
You can also change the general settings that apply to the entire seam
program.
To change the parameters of a seam program:
1.
Tap the menu items
Bearbeiten (Edit)
>
Nahtprogramm
(Seam program)
>
Parameters
.
The window for selecting the program parameter group appears:
Fig. 103: Changing the parameters of a seam program
2.
Tap the desired parameter group.
The individual parameters of this group are displayed.
3.
Tap the desired parameter.
The window for modifying the parameter value opens.
4.
Set the parameter to the desired value (
There are 8 program parameter groups:
Symbol
Parameter group
PP1 - Configuration
General settings
PP2 - Insertion mode
Insertion mode and position
PP3 - Removal mode
Removal mode and position
PP4 - Soft start
Number of stitches and speed
PP5 - Needle thread monitor
Sensitivity value for the needle thread monitor
PP6 - Thread consumption
Values for determining thread consumption
Summary of Contents for 911-211
Page 1: ...Service Instructions 911 211...
Page 6: ...Table of Contents 5 Service Instructions 911 211 02 0 10 2016...
Page 10: ...About these instructions 9 Service Instructions 911 211 02 0 10 2016...
Page 90: ...Sewing unit 89 Service Instructions 911 211 02 0 10 2016...
Page 146: ...Creating programs with DA CAD 5000 145 Service Instructions 911 211 02 0 10 2016...
Page 158: ...Decommissioning 157 Service Instructions 911 211 02 0 10 2016...
Page 160: ...Disposal 159 Service Instructions 911 211 02 0 10 2016...
Page 170: ...Technical data 169 Service Instructions 911 211 02 0 10 2016...
Page 195: ...Appendix Service Instructions 911 211 02 0 10 2016 194...
Page 197: ...Appendix Service Instructions 911 211 02 0 10 2016 196 13 3 Pneumatic diagram...
Page 199: ......