Programming
109
Service Instructions 911-211 - 02.0 - 10/2016
6.9
Resetting the counter
Depending on the machine parameter settings, the counter counts the
sewn programs or sequences up or down. You can use the
Zähler-Reset
(Reset Counter)
button to reset the counter to the start value (
To reset the counter:
1.
Tap the button
Zähler-Reset (Reset Counter)
on the start
screen.
The counter is reset to the value defined in the machine parameters.
6.10 Creating a new seam program
New seam programs are created using a Teach-In procedure.
Individual seam paths with specific seam parameters are defined via the
operating terminal in order to do this.
To create a new seam program:
1.
Tap the menu items
Datei (File)
>
Neu (New)
>
Nahtprogramm (Seam Program)
.
The Teach-In window appears.
Fig. 93: Creating a new seam program
(1)
- Cursor position
(2)
- Cursor
(3)
- Arrow buttons
(4)
- OK button: Übernahme (Accept)
(5)
- Speichern (Save) button
(6)
- Löschen (Delete) button
(7)
- Parameter button
(8)
- Linienauswahl (Line selection) button
②
③
④
⑤
⑥
⑦
⑧
①
Summary of Contents for 911-211
Page 1: ...Service Instructions 911 211...
Page 6: ...Table of Contents 5 Service Instructions 911 211 02 0 10 2016...
Page 10: ...About these instructions 9 Service Instructions 911 211 02 0 10 2016...
Page 90: ...Sewing unit 89 Service Instructions 911 211 02 0 10 2016...
Page 146: ...Creating programs with DA CAD 5000 145 Service Instructions 911 211 02 0 10 2016...
Page 158: ...Decommissioning 157 Service Instructions 911 211 02 0 10 2016...
Page 160: ...Disposal 159 Service Instructions 911 211 02 0 10 2016...
Page 170: ...Technical data 169 Service Instructions 911 211 02 0 10 2016...
Page 195: ...Appendix Service Instructions 911 211 02 0 10 2016 194...
Page 197: ...Appendix Service Instructions 911 211 02 0 10 2016 196 13 3 Pneumatic diagram...
Page 199: ......