MP2 - Limit values
Symbol
Meaning
Max. speed
(min. = 500 .. max. = 2700; Def. 2700 rpm)
All sewing programs are limited to this maximum speed
Max. run-empty speed
(min. = 10 .. max. = 100; Def. 100 %)
Limits all clamp movements between the seams to this value
Feed starting angle
(min. = 30 .. max. = 350; Def. 210 degrees)
The clamp motion during the stitch starts at this angle of needle motion
Feed phase
(min. = 30 .. max. 100; Def. 80 %)
This parameter defines how the clamp is to be moved during the stitch.
(A value of 100 % means that the desired clamp motion is distributed over
the entire stitch.)
Reversal position
(min. = 0 .. max. 359; Def. 0 degrees)
The needle is reversed at this angle in order to increase the clearance to
the clamp.
Edit times and routes
This function is only for Dürkopp Adler Service personnel
MP3 - Needle thread monitor
Symbol
Meaning
Needle thread monitor mode
The following options are available:
•
Threading position
: After detection of a thread breaking, the thread is
cut, and the clamp then moves to the threading position
•
Thread cutting
(Def.): After detection of a thread breaking, the thread is
cut, and the clamp then moves to the contour position according to the
defined reversing path
•
Pausing:
After detection of a thread breaking, seam motion is stopped
•
Not activated:
The needle thread monitor is ignored
Reversing path after thread breaking
(min. = 0 .. max. 20; Def. 5 stitches)
Number of stitches to be taken into account when reversing after a thread
breaking
Summary of Contents for 911-210-3020-10
Page 1: ...911 210 10 Operating Instructions...
Page 6: ...Table of Contents 4 Operating Instructions 911 210 10 00 0 06 2020...
Page 10: ...About these instructions 8 Operating Instructions 911 210 10 00 0 06 2020...
Page 18: ...Machine description 16 Operating Instructions 911 210 10 00 0 06 2020...
Page 34: ...Operation 32 Operating Instructions 911 210 10 00 0 06 2020...
Page 112: ...Setup 110 Operating Instructions 911 210 10 00 0 06 2020...
Page 114: ...Decommissioning 112 Operating Instructions 911 210 10 00 0 06 2020...
Page 116: ...Disposal 114 Operating Instructions 911 210 10 00 0 06 2020...
Page 124: ...Troubleshooting 122 Operating Instructions 911 210 10 00 0 06 2020...
Page 127: ......