Setting the needle bar
Service Instructions 878-M PREMIUM - 03.0 - 10/2019
29
7.2
Angular position of the single-needle sewing machine
needle holder
Proper setting
The angular position of the needle holder should be set depending on the
needle number as per the table:
Fig. 18: Angular position of the single-needle sewing machine needle holder
1.
Remove the head cover (
2.
Loosen the screw (2) and turn the needle bar so that the right end of
the groove (1) faces the needle bar axis.
3.
Tighten the screw (2).
4.
Lock the machine in place at position
2
5.
Insert the 2.5 mm Allen wrench into the opening (4) and loosen the
fixing screw of the needle holder inside the needle bar.
6.
Turn the needle holder (3) to have the correct setting.
7.
Tighten the fixing screw.
Needle holder displacement
Needle number
70 – 110
120 – 160
180 – 200
(1)
- Groove
(2)
- Screw
(3)
- Needle holder
(4)
- Opening
(5)
- 2.5 mm Alley wrench
⑤
④
②
③
①
Summary of Contents for 878-M PREMIUM
Page 1: ...878 M PREMIUM Service Instructions...
Page 10: ...About these instructions 8 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 66: ...Integrated motor 64 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 114: ...Maintenance 112 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 116: ...Decommissioning 114 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 118: ...Disposal 116 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 126: ...Technical data 124 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 127: ...Appendix Service Instructions 878 M PREMIUM 03 0 10 2019 125 23 Appendix Wiring diagram...
Page 128: ...Appendix 126 Service Instructions 878 M PREMIUM 03 0 10 2019...
Page 129: ......