FasNSeal Double-Wall vent forCategory II, III, and IV appliances
Installation Instructions
Page 1: ...FasNSeal W2 FasNSeal Double Wall vent for Category II III and IV appliances Installation Instructions...
Page 2: ...fect your homeowner s insurance and safety listing of your appliance Keep these instructions for future reference Dear Customer Installer or End User We welcome any comments regarding matters pertaini...
Page 3: ...ctions Appliance Connection 6 Condensate Drains Horizontal Through The Wall Installation 7 Vertical Through The Roof Installation 9 Exterior Wall Bracket Installation Venting Through Masonry Chimney 1...
Page 4: ...ine venting requirements and limitations with respect to installation and use of the appliance It is the responsibility of the installer to contact local building and fire officials concerning any ins...
Page 5: ...in any required clearance space around FasNSeal W2 Note Follow appliance manufacturer s allowances for elbows VENT SIZE AND LENGTH Refer to the appliance manufacturer s installation instructions for...
Page 6: ...end is seated against the flared end of the female section see photo to the right From within the tube the sealing gasket must not be visible This creates the needed airtight seal for Category II III...
Page 7: ...OUGH THE WALL INSTALLATION When venting through a sidewall terminate the system not less than 12 3m above the ground and above the snow line in geographical areas where snow accumulates The terminatio...
Page 8: ...ntinuous minimum slope of 1 4 per foot is maintained in any horizontal portion of the vent system Condensate must flow freely and may not be retained in any part of the vent system 2 Cut the opening f...
Page 9: ...mination shall not be greater than specified in the appliance manufacturer s installation instructions A FasNSeal W2 Rain Cap or any other provision as required by the appliance manufacturer must be u...
Page 10: ...ket to FasNSeal tubing using 45 50 in lb torque VENTING THROUGH A MASONRY CHIMNEY When using the FasNSeal W2 Vent System inside a masonry structure follow FasNSeal Installation Guide for Lining a Maso...
Page 11: ...losed Clearance Unenclosed Horizontal Vertical Horizontal Vertical 3 4 300 F 400 F 480 F 3 6 6 1 1 4 1 3 3 1 1 1 5 24 300 F 400 F 480 F 3 6 6 1 1 6 1 3 3 1 1 3 Rated Operating Temperature of 300 F Max...
Page 12: ...Vent Corn bio fuels driftwood or other wood containing salt preservative treated lumber plastic and household trash or garbage or wood pellets containing such materials must not be burned in the appli...