DURAVAC CVBV1210 Operator'S Manual Download Page 1

 

 

Wet/Dry Vacuums 

 

 

Operator’s Manual 

 

Wet/Dry Vacuum with Detachable Blower 

45 Liter

  

Model No.

 

CVBV1210 

 

 

 

 

 

 

 

 

 

FOR YOUR SAFETY 

Read and understand this manual before use 

Keep this manual for future reference 

www.duravac.ca 
Cleva North America  
601 Regent Park Court 
Greenville, SC 29607 

Part No. VR01BZ.20.60.02

Summary of Contents for CVBV1210

Page 1: ...with Detachable Blower 45 Liter Model No CVBV1210 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www duravac ca Cleva North America 601 Regent Park C...

Page 2: ...arranty gives you specific legal rights For product service call Customer Service at 866 384 8432 Fran ais 800 526 8563 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING...

Page 3: ...ll cord around sharp edges or corners Do not run Wet Dry Vac over cord Do not handle plug or the Wet Dry Vac with wet hands To reduce the risk of health hazards from vapors or dusts do not vacuum toxi...

Page 4: ...STEAD OF GROUNDING NO GROUNDING MEANS IS PROVIDED ON A DOUBLE INSULATED APPLIANCE NOR SHOULD A MEANS FOR GROUNDING BE ADDED SERVICING A DOUBLE INSULATED WET DRY VACUUM REQUIRES EXTREME CARE AND KNOWLE...

Page 5: ...Vac Assembly B Hose C Utility Nozzle D Caster Foot W Accessory Storage E Caster F 4 Screws Bag G Foam Sleeve Filter H Extension Wand I Car Claw J Concentrator Nozzle K Crevice Tool L Cartridge Filter...

Page 6: ...allation 8 Place the power head back on the container aligning the top section with the latches and snap into place Keep in mind to position the power head so that the blower port is towards the rear...

Page 7: ...il it stops against the power head fig 2 Your Wet Dry Vac comes with the cartridge filter pre installed if not see page 10 for installation instructions 3 Place filter retainer on top of cartridge fil...

Page 8: ...G 3 Fit the desired nozzle to the vacuum hose fig 3 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 4 5 Turn the motor on by flipping the switch to...

Page 9: ...MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED 1 Verify that the power cord is disconnected from the outlet fig 1 2 Remove noise diffuser from the blower port fig 2 3 While squeezing the locking...

Page 10: ...nd the four screws fig 5 Installing Cartridge Filter 1 Verify that the power cord is disconnected from the outlet 2 Remove lid and power head and place in upside down position 3 Install the cartridge...

Page 11: ...ly slide foam sleeve filter down over the filter cage making sure the whole cage is covered fig 2 3 4 Replace the power head on to the container Cleaning Foam Sleeve Filter 1 With the removed power he...

Page 12: ...12 EXPLODED VIEW AND PARTS...

Page 13: ...SE D CHABLE 45 Litre Mod le n CVBV1210 www duravac ca Cleva North America 601 Regent Park Court Greenville SC 29607 Pi ce no VR01BZ 20 60 02 POUR VOTRE S CURIT Veuillez lire attentivement et comprendr...

Page 14: ...donne au consommateur des droits sp cifiques Pour toute question relative l entretien du produit veuillez communiquer avec le service la client le au num ro 800 526 8563 English 866 384 8432 R GLES IM...

Page 15: ...l appareil par dessus le cordon Ne pas manipuler l aspirateur avec les mains mouill es Pour r duire les risques pour la sant attribuables aux vapeurs ou la poussi re ne pas aspirer de substances toxi...

Page 16: ...UBLE ISOLATION L ASPIRATEUR D ATELIER DOUBLE ISOLATION COMPREND DEUX SYST MES D ISOLATION AU LIEU D UN SYST ME DE MISE LA TERRE AUCUN APPAREIL DOUBLE ISOLATION NE COMPREND ET NE REQUIERT DE DISPOSITIF...

Page 17: ...utilisation D ballez le contenu et v rifiez avec la liste du contenu du carton Liste du contenu du carton Longueur du cordon prolongateur 110 V 120 V 7 5 m 25 pi 15 25 m 50 pi 30 5 m 100 pi 45 7 m 150...

Page 18: ...ur n est pas connect au r seau de courant fig 1 2 Ouvrez les verrous fig 2 3 Enlevez l unit motrice du r cipient fig 3 4 D ballez le contenu et v rifiez avec la liste du contenu du carton la page 5 fi...

Page 19: ...t muni d une fiche polaris e une lame est plus large que l autre La fiche peut tre branch e une prise polaris e d une seule fa on Si la fiche ne peut pas tre branch e compl tement dans la prise murale...

Page 20: ...t le commutateur sur la position I figure 7 7 Pour arr ter l aspirateur changer le commutateur sur la position 0 et d connectez la prise de courant O ARR T I MARCHE N UTILISEZ PAS LE FILTRE EN TISSU R...

Page 21: ...un robinet flotteur qui permet d arr ter la succion si le r servoir est rempli pleine capacit Le cas ch ant le r gime du moteur augmente Si cela se produit teindre l appareil le d brancher de la sourc...

Page 22: ...evez toute la salet et les d bris du conteneur et du tuyau fig 4 5 Nettoyez le filtre mousse avec un doux d tergent fig 5 6 V rifier que le tuyau les dispositifs de fixation et le cordon n ont pas t e...

Page 23: ...imal 4 Installer le filtre propre ou le nouveau filtre tel qu indiqu aux tapes 2 et 3 de la section Installation du filtre cartouche 5 Tout filtre humide doit tre retir Laisser le filtre s cher l air...

Page 24: ...er l alimentation lectrique le cordon d alimentation les disjoncteurs les fusibles 2 Cordon d alimentation d fectueux 2 D brancher l appareil et v rifier le cordon d alimentation Si celui ci est endom...

Page 25: ...13 SCH MA CLAT ET LISTE DES PI CES...