Duratuf TUF 200 Assembly Instructions Manual Download Page 1

Quality – Made Affordable

 

 

 

 

 

ASSEMBLY INSTRUCTIONS

 

 

TUF 200 

 

BASE SIZE 1980mm x 855mm 

Summary of Contents for TUF 200

Page 1: ...Quality Made Affordable ASSEMBLY INSTRUCTIONS TUF 200 BASE SIZE 1980mm x 855mm...

Page 2: ...checklist If you are making your own floor refer to Raised Base Plate section now Do not attempt to build your shed in high winds Beware of sharp edges Protect your eyes and ears Use electric tools w...

Page 3: ...2 010 x 1 070 Blue 45 x 45 H1 Folded Roof Sheets Roof Sheet Or Yellow 45 x 45 H1 Door Green 45 x 45 H4 Green 45 x 45 H4 DESCRIPTION Clear Roof Panel BASE PLATES Red 70 x 45 H1 Corner Wall Sheets 3 4...

Page 4: ...te 70x45mm Step 3 Position remaining End Frame on top of plates While someone sup ports frame nail in place using two 75mm nails per join Step 4 Carefully roll frame over onto its base Nail on Back an...

Page 5: ...Door Jambs Position left hand Door Jamb Flashing at correct measurement from left cladding detail and nail to Top Plate using a 30mm clout Do not fit 50mm nails at this stage Pre drill holes to make n...

Page 6: ...doorway Rivet to Corner Wall Sheet one rivet top and bottom Posi tion and rivet in place all remaining Wall Sheets ensuring they overlap correctly While holding Front Wall Sheets up against Top Plate...

Page 7: ...th caution Position Roof Sheets as shown in fig 1 When fitting Clear Panel ensure it OVERLAPS Roof Sheets Rivet sheet joins one rivet 300mm from edge front and back When riveting Clear Panel to Roof S...

Page 8: ...late Flashing and fit one rivet to top hinge While still holding in position fit one rivet to bottom hinge Step 3 Close door and check it fits correctly If not drill out rivets and make necessary adju...

Page 9: ...RITY DOOR Optional Step 1 Place shed in final position Check diagonal meas urements are equal and shed is level before fitting door Step 2 Hold Door in position approximately 5mm down from Top Plate F...

Page 10: ...l Sheets will then protrude 20mm below the Base Plate This will stop water flowing in between the Base Plate and Floor If you choose this option the Floor should be made 15mm smaller than Base Size No...

Page 11: ...in most environments The surface must be dry and free of dirt oil grease and other contaminants prior to painting but no weathering of the surface is required Zinc rich primers are recommended for us...

Page 12: ...nd very severe environmental situations or in any area where the mild steel corrosion rate as published by BRANZ exceeds 200g m2 3 Minimum maintenance must be carried out in accordance with instructio...

Reviews: