background image

Revision 1.0 

12.11.2013 

 
 

 

 
 

HEAT PUMP FOR SWIMMING POOL 

Installation and Instruction Manual 

 
 

 

 

Summary of Contents for ECO+ Series

Page 1: ...Revision 1 0 12 11 2013 HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual...

Page 2: ...pical configuration 6 3 5 Water connections 6 3 6 Electrical connection 7 3 7 Initial startup of the unit 7 3 8 Condensation 8 4 Guidelines 9 4 1 Water chemistry 9 4 2 Winterizing 9 4 3 Spring startup...

Page 3: ...nce The Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant Our ECO heat pumps have the following characteristics 1 Durable The heating exchanger is made of P...

Page 4: ...W 70 70 80 80 Fan speed rpm 950 950 1200 1200 Fan direction vertical vertikaal vertikaal vertikaal Noise at 2m dB A 53 54 57 58 Water connection Inch 1 5 1 5 1 5 1 5 Nominal water flow m3 h 3 12 4 12...

Page 5: ...are present 1 Fresh air 2 Electricity 3 Swimming pool filter pipes The unit may be installed virtually anywhere outdoors when minimal distance to other objects is respected 3 3 How close to the pool I...

Page 6: ...3 5 Water connections The piping to and from the heat pump need to have a 50mm outer diameter and need to be glued to water connections that came with the heat pump These pipes can be hard PVC or flex...

Page 7: ...following guidelines for the rest of the electrical installation Model Power supply Circuit breaker Running current Cable section for 15m of cable Cable section for 50m of cable ECO 4 220 240V 16A 3...

Page 8: ...e Several days will be needed to bring the temperature of the swimming pool water to its required value depending on the initial water temperature and the ambient temperature A good pool cover and ins...

Page 9: ...aturated water into the heat pump where it will damage the components 4 2 Winterizing Caution failure to winterize could cause damage to the heat pump and will void warranty Although our ECO heat pump...

Page 10: ...er water Immediately call a qualified professional technician to inspect the heat pump and replace any part of the control system which has been submerged The heat pump will produce condensation water...

Page 11: ...arrow keys The setting will automatically be stored in memory A choice can be made between C and F as follows Cut electrical power to the unit Press both arrow keys at the same time and restore electr...

Page 12: ...de Improper installation will create an electrical hazard which could result in death or serious injury to pool users installers or others due to electrical shock and may also cause damage to property...

Page 13: ...ed off 4 Low flow Insufficient water flow The fan has stopped but the compressor is still running Solution check the water flow 5 Flow error There is too little water flowing through the heat pump and...

Page 14: ...freezing or other conditions causing inadequate water circulation 6 Operating the product at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized...

Reviews: