background image

HSC-100

Handheld Barcode Scanner

User Guide

Summary of Contents for HSC-100

Page 1: ...HSC 100 Handheld Barcode Scanner User Guide...

Page 2: ...liability function or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted...

Page 3: ...Revision History Version Description Date V1 0 0 Initial release April 22 2016...

Page 4: ...Cable 5 Using RS 232 Cable 5 Using PS 2 Cable 5 Removing Communication Cable 6 Power On Sleep Power Off Reboot 6 Maintenance 7 Dimensions unit mm 8 Left View 8 Front View 8 Top View 8 Scanning Instruc...

Page 5: ...Port Emulation 27 USB HID POS 27 Introduction 27 Access the Scanner with Your Program 28 Acquire Scanned Data 28 Send Data to the Scanner 28 VID PID 28 PS 2 Interface 29 Chapter 3 Scan Mode 30 Batch M...

Page 6: ...n Aiming 42 Illumination 42 Aiming 43 Chapter 6 Beep LED Notifications 44 Startup Beep 44 Good Read Beep for Non programming Barcode 44 Beep Type 45 Beep Volume 45 Beep on Unknown Character 46 Good Re...

Page 7: ...Disable All Symbologies 58 Enable Disable 1D Symbologies 58 Enable Disable 2D Symbologies 58 Video Reverse 59 1D Symbologies 60 Code 128 60 Restore Factory Defaults 60 Enable Disable Code 128 60 Set...

Page 8: ...n Code 69 Add On Code Required 69 ISBN 70 Restore Factory Default 70 Enable Disable ISBN 70 Set ISBN Format 70 Add On Code 71 Add On Code Required 71 UPC E 72 Restore Factory Defaults 72 Enable Disabl...

Page 9: ...ation 84 Industrial 2 of 5 85 Restore Factory Defaults 85 Enable Disable Industrial 2 of 5 85 Set Length Range for Industrial 2 of 5 85 Check Digit Verification 86 Standard 2 of 5 IATA 2 of 5 87 Resto...

Page 10: ...97 Enable Disable GS1 Databar 97 Transmit Application Identifier 01 97 Code 11 98 Restore Factory Defaults 98 Enable Disable Code 11 98 Set Length Range for Code 11 98 Transmit Check Digit 99 Check Di...

Page 11: ...108 Restore Factory Defaults 108 Enable Disable Data Matrix 108 Set Length Range for Data Matrix 108 Rectangular Barcode 109 Mirror Image 109 Data Matrix Twin Code 110 Character Encoding 110 Chinese S...

Page 12: ...endix 2 AIM ID Table 139 Appendix 3 Code ID Table 141 Appendix 4 ASCII Table 142 Appendix 5 Parameter Programming Examples 146 a Program the Decode Session Timeout 146 b Program the Time Period from I...

Page 13: ...scanner to get proper output for Russian encoded with Windows 1251 151 p Program the scanner to get proper output for Russian encoded with UTF 8 151 Appendix 6 Digit Barcodes 152 Appendix 7 Save Canc...

Page 14: ......

Page 15: ...s well as GS1 DataBarTM RSS Limited Stacked Expanded versions It can read barcodes on virtually any medium paper plastic card mobile phones and LCD displays About This Guide This guide provides progra...

Page 16: ...Enter Setup Exit Setup 2 HSC 100 Scanner Decode LED Green Barcode is decoded successfully Decode LED Logo Scan Window Label Trigger Data Port...

Page 17: ...ock signal PS 2 2 KB_DATA I O Keyboard data signal PS 2 3 VCC P Power DC5V 4 TXD O RS 232 output 5 RXD I RS 232 input 6 PC_CLK CTS I O PC clock signal PS 2 Clear to send RS 232 7 PC_DATA RTS I O PC da...

Page 18: ...pplication such as PC POS or any intelligent terminal with USB or RS 232 port or PS 2 interface using a communication cable USB or RS 232 or PS 2 cable USB USB port on the Host RS 232 RS 232 port on t...

Page 19: ...canner 2 Plug the USB connector into the USB port on the Host Using RS 232 Cable Connect the scanner to a Host through an RS 232 cable with RJ45 RS 232 and power connectors 1 Plug the RJ45 connector i...

Page 20: ...plug the power adapter into the power jack on the PS 2 cable 4 When required connect the PS 2 cable to a keyboard via its PS 2 port Removing Communication Cable Get an appropriate needle or a straigh...

Page 21: ...tion cable from the Host or disconnect the power adaptor from mains Reboot the scanner If the scanner stops responding to input or runs abnormally turn off the scanner and then turn it back on Mainten...

Page 22: ...Enter Setup Exit Setup 8 Dimensions unit mm Left View Front View Top View...

Page 23: ...ed aiming beam 2 Aim the red beam across the center of barcode as shown below 3 Release the Trigger when the red beam goes off If the barcode is decoded successfully the scanner will emit a good read...

Page 24: ...mming barcodes such as the Enter Setup barcode and Restore All Factory Defaults barcode can be read Enter Setup Exit Setup Programming barcode data can be transmitted to the Host Scan the appropriate...

Page 25: ...possible to save the frequently used settings on the scanner Scanning the Save as Custom Defaults barcode can save the current settings as custom defaults Once custom default settings are stored they...

Page 26: ...ner provides a TTL 232 interface a USB interface and a PS 2 interface to communicate with the host device The host device can receive scanned data and send commands to control the scanner or to access...

Page 27: ...Moreover you need to set communication parameters including baud rate parity check data bit and stop bit to match the host device RS 232 Default serial communication parameters are listed below Make s...

Page 28: ...Enter Setup Exit Setup 14 Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the Host requirements 9600 1200 19200 2400 38400 4800 57600 14400 115200...

Page 29: ...to 7 you can only select either Even Parity or Odd Parity The None option will be regarded as Even Parity in this case None Even Parity Odd Parity Data Bit When the number of data bits is set to 7 yo...

Page 30: ...Enter Setup Exit Setup 16 Data Bit Parity Check 7 Data Bits Even Parity 7 Data Bits Odd Parity 8 Data Bits No Parity 8 Data Bits Even Parity 8 Data Bits Odd Parity Stop Bit 1 Stop Bit 2 Stop Bits...

Page 31: ...g between scanners of same model Driver installation is required for each USB device distinguished from others by the host device in the process of enumeration USB HID KBW When you connect the scanner...

Page 32: ...Setup Exit Setup 18 Polling Rate This parameter specifies the polling rate for a USB keyboard If the Host drops characters change the polling rate to a bigger value 1ms 2ms 3ms 4ms 5ms 6ms 7ms 8ms 9ms...

Page 33: ...Enter Setup 19 Exit Setup USB Country Keyboard Types Keyboard layouts vary from country to country The default setting is U S keyboard U S Belgium Brazil Canada Czechoslovakia Denmark Finland France...

Page 34: ...Enter Setup Exit Setup 20 Germany Austria Greece Hungary Israel Italy Latin America South America Netherlands Norway Poland Portugal...

Page 35: ...Setup Romania Russia Slovakia Spain Sweden Switzerland Turkey_F Turkey_Q UK Japan Note To program the scanner to get proper output for Russian encoded with Windows 1251 or UTF 8 PDF417 QR Code Data Ma...

Page 36: ...own characters Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected Beep on Unknown Character Do Not Beep on Unknown Character Inter Keyst...

Page 37: ...ow to convert barcode data to your desired case No Case Conversion Invert Upper and Lower Case Characters Convert All to Upper Case Convert All to Lower Case Example When the Invert Upper and Lower Ca...

Page 38: ...ed keyboard type but falling into 0x20 0xFF are sent in the ALT Keypad way Mode 2 ASCII characters falling into 0x20 0xFF are sent in the ALT Keypad way Mode 3 ASCII characters falling into 0x00 0xFF...

Page 39: ...tion characters 0x00 0x1F are sent as ASCII sequences over the keypad For more information see Appendix 8 ASCII Function Key Mapping Table Example Barcode data 0x16 Enable Function Key Mapping Ctrl V...

Page 40: ...ke _ and is still emulated as keystrokes on main keyboard Do Not Emulate Numeric Keypad Emulate Numeric Keypad Code Page The Code Page programming feature is provided to support more international cha...

Page 41: ...interface is recommended for new application programs It can send up to 56 characters in a single USB report and appears more efficient than keyboard emulation Features HID based no custom driver requ...

Page 42: ...erfaces go to www USB org Acquire Scanned Data After scanning and decoding a barcode the scanner sends the following input report Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 0x02 1 Length of the barcode 2 57...

Page 43: ...Product Interface PID Hex PID Dec HSC 100 USB HID KBW 1A03 6659 USB COM Port Emulation 1A06 6662 USB HID POS 1A10 6672 PS 2 Interface When the scanner is connected to the PS 2 port of a host device s...

Page 44: ...pter 3 Scan Mode Batch Mode A trigger pull activates a round of multiple decode sessions This round of multiple scans continues until you release the trigger Rereading the same barcode is not allowed...

Page 45: ...u release the trigger or decode session timeout expires Manual Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt It is programmable in 1ms...

Page 46: ...erformed for a time period user programmable When the scanner is in the sleep mode pressing the Trigger or receiving command from the host device can awake the scanner The scanner returns to full oper...

Page 47: ...Do not allow the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Allow the scanner to re read same barcode The following parame...

Page 48: ...e a trigger pull can also activate a decode session The decode session continues until the barcode is decoded or the trigger is released When the session ends the scanner continues to monitor ambient...

Page 49: ...rogrammable in 1ms increments from 0ms to 1 600ms The default setting is 500ms To learn how to program this parameter see Appendix 5 Continue after Good Read Continue after Good Read The scanner start...

Page 50: ...Do not allow the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Allow the scanner to re read same barcode Disable Timeout betw...

Page 51: ...ironment Medium Sensitivity Low Sensitivity High Sensitivity Enhanced Sensitivity If the above four options fail to meet your needs you may program the threshold value of illumination change Illuminat...

Page 52: ...empt It is programmable in 1ms increments from 0ms to 3 600 000ms The default setting is 3 000ms To learn how to program this parameter see Appendix 5 Decode Session Timeout Timeout between Decodes Th...

Page 53: ...Do not allow the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Allow the scanner to re read same barcode Disable Timeout betw...

Page 54: ...its field of view from the center to the periphery and transmits the barcode that has been first decoded Whole Area Decoding Central Area Decoding The scanner attempts to decode barcode s within a sp...

Page 55: ...he central area by scanning the Specify Central Area barcode and numeric barcode s corresponding to a desired percentage 1 100 If Central Area Decoding is enabled by scanning the Central Area Decoding...

Page 56: ...umination options are provided to improve the lighting conditions during every image capture Normal Illumination LEDs are turned on during image capture Always ON Illumination LEDs keep ON after the s...

Page 57: ...llows positioning the target barcode within its field of view and thus makes decoding easier Normal The scanner projects an aiming pattern only during barcode scanning capture Always ON Aiming pattern...

Page 58: ...e Startup Beep Disable Startup Beep Good Read Beep for Non programming Barcode Scan the appropriate barcode below to enable or disable the emission of beep when a non programming barcode is decoded Be...

Page 59: ...Enter Setup 45 Exit Setup Beep Type Type 1 Type 3 Type 2 Beep Volume Loud Low Medium...

Page 60: ...lt the scanner fails to transmit the unknown characters Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected Beep on Unknown Character Do...

Page 61: ...n a barcode cannot be decoded Transmit NGR Message Do Not Transmit NGR Message Edit NGR Message To edit an NGR message scan the Edit NGR Message barcode and the numeric barcodes corresponding to the A...

Page 62: ...can also be the alternatives Data editing may include Append AIM ID Code ID custom prefix before the decoded data Append custom suffix after the decoded data Append terminating character to the end of...

Page 63: ...ta with no prefix suffix Enable All Prefixes Suffixes Allow user to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission Enabl...

Page 64: ...ble Custom Prefix Set Custom Prefix To set a custom prefix scan the Set Custom Prefix barcode and the numeric barcodes representing the hexadecimal value s of a desired prefix and then scan the Save b...

Page 65: ...er will add the symbology identifier before the scanned data after decoding Enable AIM ID Prefix Disable AIM ID Prefix Code ID Prefix Code ID can also be used to identify barcode type Unlike AIM ID Co...

Page 66: ...and then scan the Save barcode Refer to Appendix 4 ASCII Table for hexadecimal values of characters To view a setting example see Appendix 5 Parameter Programming Examples Modify PDF417 Code ID Modify...

Page 67: ...y UPC A Code ID Modify ISBN Code ID Modify ISSN Code ID Modify Code 39 Code ID Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID Modify ITF 14 Code ID Modify ITF 6 Code ID Modify Codabar Code I...

Page 68: ...Enter Setup Exit Setup 54 Modify Standard 25 Code ID Modify Matrix 25Code ID Modify COOP 25 Code ID Modify Code 11 Modify Plessey Code ID Modify MSI Plessey Code ID Modify GS1 Databar Code ID...

Page 69: ...ble Custom Suffix Set Custom Suffix To set a custom suffix scan the Set Custom Suffix barcode and the numeric barcodes representing the hexadecimal value s of a desired prefix and then scan the Save b...

Page 70: ...of data which means nothing can be added after it A terminating character suffix can contain 1 7 characters Enable Disable Terminating Character Suffix To enable disable terminating character suffix s...

Page 71: ...LF 0x0D 0x0A To set a terminating character suffix scan the Set Terminating Character Suffix barcode and the numeric barcodes representing the hexadecimal value s of a desired terminating character an...

Page 72: ...programming barcodes Enable All Symbologies Disable All Symbologies Enable Disable 1D Symbologies If the Disable 1D Symbologies feature is enabled the scanner will not be able to read any 1D barcodes...

Page 73: ...rcode and inverse barcode are shown below Regular Barcode Inverse Barcode Video Reverse allows the scanner to read barcodes that are inverted Video Reverse ON Read both regular barcodes and inverse ba...

Page 74: ...0 1D Symbologies Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 Set Length Range for Code 128 Set the Minimum Lengt...

Page 75: ...Setup GS1 128 UCC EAN 128 Restore Factory Defaults Restore the Factory Defaults of GS1 128 Enable Disable GS1 128 Enable GS1 128 Disable GS1 128 Set Length Range for GS1 128 Set the Minimum Length Set...

Page 76: ...it Setup 62 AIM 128 Restore Factory Defaults Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 Enable AIM 128 Disable AIM 128 Set Length Range for AIM 128 Set the Minimum Length Set the M...

Page 77: ...the Factory Defaults of EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Transmit Check Digit EAN 8 is 8 digits in length with the last one as its check digit used to verify the integrity of the...

Page 78: ...e Enable 2 Digit Add On Code Disable 2 Digit Add On Code Enable 5 Digit Add On Code Disable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of EAN 8...

Page 79: ...EAN 8 barcodes that contain add on codes EAN 8 Add On Code Required EAN 8 Add On Code Not Required EAN 8 Extension Disable EAN 8 Zero Extend Transmit EAN 8 barcodes as is Enable EAN 8 Zero Extend Add...

Page 80: ...Setup 66 EAN 13 Restore Factory Defaults Restore the Factory Defaults of EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit Do Not Transmit EAN...

Page 81: ...e scanner decodes a mix of EAN 13 barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code...

Page 82: ...Enter Setup Exit Setup 68 ISSN Restore Factory Defaults Restore the Factory Defaults of ISSN Enable Disable ISSN Enable ISSN Disable ISSN...

Page 83: ...Code The scanner decodes a mix of ISSN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISSN and ignores the add on co...

Page 84: ...Enter Setup Exit Setup 70 ISBN Restore Factory Default Restore the Factory Defaults of ISBN Enable Disable ISBN Enable ISBN Disable ISBN Set ISBN Format ISBN 13 ISBN 10...

Page 85: ...Code The scanner decodes a mix of ISBN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISBN and ignores the add on co...

Page 86: ...Exit Setup 72 UPC E Restore Factory Defaults Restore the Factory Defaults of UPC E Enable Disable UPC E Enable UPC E Disable UPC E Transmit Check Digit Transmit UPC E Check Digit Do Not Transmit UPC E...

Page 87: ...The scanner decodes a mix of UPC E barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC E and ignores the add on code...

Page 88: ...code is the system character 0 Transmit System Character 0 Do Not Transmit System Character 0 UPC E Extension Disable UPC E Extend Transmit UPC E barcodes as is Enable UPC E Extend Extend UPC E barcod...

Page 89: ...75 Exit Setup UPC A Restore Factory Defaults Restore the Factory Defaults of UPC A Enable Disable UPC A Enable UPC A Disable UPC A Transmit Check Digit Transmit UPC A Check Digit Do Not Transmit UPC A...

Page 90: ...The scanner decodes a mix of UPC A barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC A and ignores the add on code...

Page 91: ...nter Setup 77 Exit Setup Transmit Preamble Character 0 Transmit Preamble Character 0 Do not Transmit Preamble Character 0 Note The preamble character 0 usually does not appear in printed UPC A barcode...

Page 92: ...store Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set Length Range for Interleaved 2 of 5...

Page 93: ...2 of 5 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted except the last digit whereas those failing it will not be transmitted T...

Page 94: ...Enter Setup Exit Setup 80 Disable Enable Febraban Disable Febraban Enable Febraban Do Not Expand Enable Febraban Expand...

Page 95: ...length of 14 characters and the last character as the check digit Restore the Factory Defaults of ITF 14 Disable ITF 14 Enable ITF 14 But Do Not Transmit Check Digit Enable ITF 14 and Transmit Check D...

Page 96: ...a length of 6 characters and the last character as the check digit Restore the Factory Defaults of ITF 6 Disable ITF 6 Enable ITF 6 But Do Not Transmit Check Digit Enable ITF 6 and Transmit Check Digi...

Page 97: ...2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Set Length Range for Matrix 2 of 5 Set the Minimu...

Page 98: ...Enter Setup Exit Setup 84 Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification...

Page 99: ...Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Industrial 2 of 5 Disable Industrial 2 of 5 Set Length Range for Industrial 2 of 5 Se...

Page 100: ...Enter Setup Exit Setup 86 Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification...

Page 101: ...2 of 5 IATA 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Standard 25 Enable Disable Standard 25 Enable Standard 25 Disable Standard 25 Set Length Range for Standard 25 Set the Mini...

Page 102: ...Enter Setup Exit Setup 88 Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification...

Page 103: ...Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do not Trans...

Page 104: ...Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification Enable Disable Code 39 Full ASCII The scanner can be configured to identify all ASCII...

Page 105: ...e 39 must be enabled and Code 39 check digit verification must be disabled for this parameter to function Disable Convert Code 39 to Code 32 Enable Convert Code 39 to Code 32 Code 32 Prefix Scan the a...

Page 106: ...it Setup 92 Codabar Restore Factory Defaults Restore the Factory Defaults of Codabar Enable Disable Codabar Enable Codabar Disable Codabar Set Length Range for Codabar Set the Minimum Length Set the M...

Page 107: ...etup Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification Transmit Start Stop Character Transmit Start Stop Character Do not Transmit...

Page 108: ...ormat You can choose your desired start stop character format by scanning the appropriate barcode below ABCD ABCD as the Start Stop Character ABCD TN E as the Start Stop Character Start Stop Character...

Page 109: ...Exit Setup Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable Disable Code 93 Enable Code 93 Disable Code 93 Set Length Range for Code 93 Set the Minimum Length Set the M...

Page 110: ...Enter Setup Exit Setup 96 Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification...

Page 111: ...store Factory Defaults Restore the Factory Defaults of GS1 Databar Enable Disable GS1 Databar Enable GS1 DataBar Disable GS1 DataBar Transmit Application Identifier 01 Transmit Application Identifier...

Page 112: ...it Setup 98 Code 11 Restore Factory Defaults Restore the Factory Defaults of Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Set Length Range for Code 11 Set the Minimum Length Set the M...

Page 113: ...Do Not Transmit Check Digit Check Digit Verification Disable One Check Digit MOD11 Two Check Digits MOD11 MOD11 Two Check Digits MOD11 MOD9 One Check Digit MOD11 Len 10 Two Check Digits MOD11 MOD11 Le...

Page 114: ...it Setup 100 Plessey Restore Factory Defaults Restore the Factory Defaults of Plessey Enable Disable Plessey Enable Plessey Disable Plessey Set Length Range for Plessey Set the Minimum Length Set the...

Page 115: ...Enter Setup 101 Exit Setup Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification...

Page 116: ...MSI Plessey Restore Factory Defaults Restore the Factory Defaults of MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Set Length Range for MSI Plessey Set the Minimum Len...

Page 117: ...Setup 103 Exit Setup Transmit Check Digit Transmit Check Digit Do Not Transmit Check Digit Check Digit Verification Disable One Check Digit MOD10 Two Check Digits MOD10 MOD10 Two Check Digits MOD10 M...

Page 118: ...104 2D Symbologies PDF 417 Restore Factory Defaults Restore the Factory Defaults of PDF 417 Enable Disable PDF 417 Enable PDF 417 Disable PDF 417 Set Length Range for PDF 417 Set the Minimum Length S...

Page 119: ...s and be placed closely together There are 3 options for reading PDF417 twin codes Single PDF417 Only Read either PDF417 code Twin PDF417 Only Read both PDF417 codes Both Single Twin Read both PDF417...

Page 120: ...Restore Factory Defaults Restore the Factory Defaults of QR Code Enable Disable QR Code Enable QR Code Disable QR Code Set Length Range for QR Code Set the Minimum Length Set the Maximum Length Micro...

Page 121: ...specifications and be placed closely together There are 3 options for reading QR twin codes Single QR Only Read either QR code Twin QR Only Read both QR codes Both Single Twin Read both QR codes If s...

Page 122: ...Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable Disable Data Matrix Enable Data Matrix Disable Data Matrix Set Length Range for Data Matrix Set the Minimum Len...

Page 123: ...Enter Setup 109 Exit Setup Rectangular Barcode Enable Rectangular Barcode Disable Rectangular Barcode Mirror Image Decode Mirror Images Do Not Decode Mirror Images...

Page 124: ...n codes Single Data Matrix Only Read either Data Matrix code Twin Data Matrix Only Read both Data Matrix codes Transmission order Data Matrix code on the left in the upper position followed by the one...

Page 125: ...Factory Defaults Restore the Factory Defaults of Chinese Sensible Code Enable Disable Chinese Sensible Code Enable Chinese Sensible Code Disable Chinese Sensible Code Set Length Range for Chinese Sen...

Page 126: ...mage captured by the scanner to meet actual need by scanning the appropriate barcode on the next page The following figures illustrate original image and three flipped images Original Image Image Flip...

Page 127: ...13 Exit Setup Flip Do Not Flip Flip Vertically Flip Horizontally Flip Horizontally and Vertically Flip Vertically Flip Vertically Do Not Flip Vertically Flip Horizontally Flip Horizontally Do Not Flip...

Page 128: ...acters By default the data formatter is disabled Enable it when required If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data...

Page 129: ...d type Specify what type of formatter commands will be used Scan a numeric barcode 6 to select formatter command type 6 See the Formatter Command Type 6 section in this chapter for more information St...

Page 130: ..._0 using formatter command type 6 Code 128 containing 10 characters applicable send all characters followed by A 1 Scan the Enter Setup barcode Enter the Setup mode 2 Scan the Add Data Format barcode...

Page 131: ...to apply the data format 3 characters 999 indicates all symbologies Data length The length of data that will be acceptable for this symbology 4 characters 9999 indicates all lengths For example 32 ch...

Page 132: ...he data format selected here then reverts to the format you have selected above For example you may have set your scanner to the data format you saved as Format_3 You can switch to Format_1 for a sing...

Page 133: ...at requirements is modified accordingly and gets outputted without prefixes and suffixes even if prefix and suffix are enabled Any data that does not match your data format requirements generates an e...

Page 134: ...er generates an error beep when a barcode is encountered that does not match your required data format Non Match Error Beep ON Non Match Error Beep OFF Clear Data Format There are two methods to remov...

Page 135: ...age starting from current cursor position followed by an insert character F2 Send a number of characters Syntax F2nnxx nn The numeric value 00 99 for the number of characters xx The insert character s...

Page 136: ...return Command string F3440D F3 is the Send all characters up to a particular character command 44 is the hex value for a D 0D is the hex value for a CR The data is output as 1234567890ABC CR E9 Send...

Page 137: ...end to ignore F4 is the Insert a character multiple times command 09 is the hex value for a horizontal tab 02 is the number of time the tab character is sent The data is output as 1234567890AB tab tab...

Page 138: ...ce 01 is the number of time the space character is sent B4 is the Insert barcode length command F4 is the Insert a character multiple times command 20 is the hex value for a space 01 is the number of...

Page 139: ...cursor F1 is the Send all characters command 0D is the hex value for a CR The data is output as 4567890ABCDEFGHIJ CR F6 Move the cursor backward a number of characters Syntax F6nn nn The numeric valu...

Page 140: ...Search for the letter D in barcodes and send all the data that follows including the D Using the barcode above Command string F844F10D F8 is the Search forward for a character command 44 is the hex v...

Page 141: ...data that follows including FGH Using the barcode above Command string B00003464748F10D B0 is the Search forward for a string command 0003 is the string length 3 characters 46 is the hex value for F...

Page 142: ...ll the data that follows E6 searches forward for the first character that is not zero then sends all the data after followed by a carriage return Using the barcode above Command string E630F10D E6 is...

Page 143: ...ou may want to remove the spaces before sending the data Using the barcode above Command string FB0120F10D FB is the Suppress characters command 01 is the number of the characters to be suppressed 20...

Page 144: ...ll replace the zeros in the barcode above with carriage returns Command string E402300DF10D E4 is the Replace characters command 02 is the total count of characters to be replaced plus the replacement...

Page 145: ...olution 1 If this problem happens to all barcodes and additional characters appear before after barcode data disable all prefix suffix 2 If this problem only happens to some barcodes and matches one o...

Page 146: ...hat the scanner is properly powered up 2 Send to the scanner If the scanner returns a reply of then send programming commands to turn on illumination and aimer Problem Carriage Return Line Feed settin...

Page 147: ...p Bits 1 Hardware Flow Control No flow control HID KBW Polling Rate 1ms USB Country Keyboard Type U S Convert Case No conversion Inter Keystroke Delay 0ms Beep on Unknown Character Do not beep Emulate...

Page 148: ...se mode Continuous mode 0 3 600 000ms Image Stabilization Timeout 500ms 0 1 600ms Operation after Good Read Pause after good read Timeout between Decodes Same Barcode Disabled 1 500ms 0 65 535ms Thres...

Page 149: ...ed Good Read LED Enabled NGR Not Good Read Message Do not transmit None Prefix Suffix Prefix Sequence Custom Prefix Code ID AIM ID Custom Prefix Disabled None AIM ID Prefix Disabled Code ID Prefix Dis...

Page 150: ...IM 128 AIM 128 Enabled Maximum Length 127 Minimum Length 1 EAN 8 EAN 8 Enabled Check Digit Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not required Extend to EAN 13...

Page 151: ...led Add On Code Not required Extend to UPC A Disabled System Character 0 Transmit UPC A UPC A Enabled Check Digit Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not req...

Page 152: ...git Verification Disabled Check Digit Do not transmit Maximum Length 127 Minimum Length 6 Standard 2 of 5 Standard 2 of 5 Enabled Check Digit Verification Disabled Check Digit Do not transmit Maximum...

Page 153: ...93 Code 93 Enabled Check Digit Verification Enabled Check Digit Do not transmit Maximum Length 127 Minimum Length 3 GS1 Databar GS1 Databar Enabled Application Identifier 01 Transmit Code 11 Code 11...

Page 154: ...racter Encoding Default Character Encoding QR Code QR Code Enabled Micro QR Enabled Maximum Length 7089 Minimum Length 1 QR Twin Code Read single QR only Character Encoding Default Character Encoding...

Page 155: ...t transmit check digit after verification ITF 6 I1 Transmit check digit I3 Do not transmit check digit ITF 14 I1 Transmit check digit I3 Do not transmit check digit Industrial 2 of 5 S0 Not specified...

Page 156: ...17 L0 Comply with 1994 PDF417 specifications Data Matrix d0 ECC000 ECC140 d1 ECC200 d2 ECC200 FNC1 is the 1st or 5th character after the start character d3 ECC200 FNC1 is the 2nd or 6th character afte...

Page 157: ...EAN 8 d EAN 13 d ISSN n ISBN B UPC E c UPC A c Interleaved 2 of 5 Febraban e ITF 6 e ITF 14 e Matrix 2 of 5 v Industrial 2 of 5 D Standard 2 of 5 s Code 39 Code 32 b Codabar a Code 93 i Code 11 H Ples...

Page 158: ...eed 0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC...

Page 159: ...llar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forwar...

Page 160: ...5 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 9...

Page 161: ...0 D 65 101 E 66 102 F 67 103 G 68 104 H 69 105 I 6a 106 J 6b 107 K 6c 108 L 6d 109 M 6e 110 N 6f 111 O 70 112 P 71 113 Q 72 114 R 73 115 S 74 116 T 75 117 U 76 118 V 77 119 W 78 120 X 79 121 Y 7a 122...

Page 162: ...Idle to Sleep Example Set the time period from idle to sleep to 500ms 1 Scan the Enter Setup barcode 2 Scan the Time Period from Idle to Sleep barcode See the Auto Sleep section in Chapter 3 3 Scan th...

Page 163: ...e threshold value of illumination change to 4 1 Scan the Enter Setup barcode 2 Scan the Threshold Value of Illumination Change barcode See the Sensitivity section in Chapter 3 3 Scan the numeric barco...

Page 164: ...Setup barcode 3 Scan the Set Custom Prefix barcode See the Set Custom Prefix section in Chapter 6 4 Scan the numeric barcodes 4 3 4 F 4 4 4 and 5 5 Scan the Save barcode 6 Scan the Exit Setup barcode...

Page 165: ...x values of ERR in the ASCII Table ERR 21 45 52 52 2 Scan the Enter Setup barcode 3 Scan the Edit NGR Message barcode See the Edit NGR Message section in Chapter 5 4 Scan the numeric barcodes 2 1 4 5...

Page 166: ...Range for Code 128 section in Chapter 7 3 Scan the numeric barcode 8 4 Scan the Save barcode 5 Scan the Set the Maximum Length barcode See the Set Length Range for Code 128 section in Chapter 7 6 Sca...

Page 167: ...tion in Chapter 2 8 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step p Program the scanner to get proper output for Russian encoded with UTF 8 1 Scan the...

Page 168: ...154 Appendix 6 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9...

Page 169: ...155 A F A B C D E F...

Page 170: ...st Digit barcode and then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you...

Page 171: ...VT Vertical Tab 0B Vertical Tab Ctrl K FF Form Feed 0C Backspace Ctrl L CR Carriage Return 0D Enter Ctrl M SO Shift Out 0E Insert Ctrl N SI Shift In 0F Esc Ctrl O DLE Data Link Escape 10 F11 Ctrl P D...

Page 172: ...B 1C 1D 1E 1F United States Ctrl Ctrl Ctrl Ctrl 6 Ctrl Belgium Ctrl Ctrl Ctrl Ctrl 6 Ctrl Scandinavia Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl France Ctrl Ctrl 8 Ctrl Ctrl 6 Ctrl Germany Ctrl Ctrl Ctrl 6 Ctrl I...

Page 173: ...159 Appendix 9 Code Pages List Numeric Barcode Needed Code Page 0 Windows 1252 Latin I 1 Windows 1251 Cyrillic...

Page 174: ...006 UPC A 007 Interleaved 2 of 5 Febraban 008 ITF 14 009 ITF 6 010 Matrix 2 of 5 011 Code 39 Code 32 013 Codabar 015 Code 93 017 AIM 128 020 ISSN 023 ISBN 024 Industrial25 025 Standard25 026 Plessey...