OPEN/CLOSE time
Approx. 2 seconds
Ambient temperature
-20…+120°C (-4…+248°F)
IP Code (IEC 60529)
IP65
Installation altitude
≤ 2000 m above msl
Dimensions (HxWxD):
Approx. 250 x 200 x 150 mm
Weight
Approx. 4.5 kg
Material
Shut-off shutter: Stainless steel 1.4571
housing: Aluminium, painted
Table 9.5: Technical data, D-SK 290 MA fail-safe shutter protective device
D-TB 100 supply unit (terminal box)
Operating voltage
90…264 V~, 48…62 Hz)
Output voltage
24 V
Overvoltage category
CAT II
Ambient temperature
-25…+55°C (-13…+131°F)
IP Code (IEC 60529)
IP65 (NEMA 4, 4X)
Installation altitude
≤ 2000 m above msl
Dimensions (HxWxD):
approx. 160 x 230 x 105 mm or 180 x 230 x 105 mm
Tests for Flammability of Plastic Materials for
Parts in Devices and Applications
to IEC/DIN EN 60695-11 -10 and -20, UL 94-V0
Weight
Approx. 1.5 kg
Material
Polycarbonate, light grey RAL 7035
Table 9.6: Technical data, D-TB 100 supply unit (terminal box)
D-BL XXX purge air unit
Power supply
115/230 V~, 50/60 Hz *
0,4 kW /0,5 kW
Overvoltage category
CAT II
Purge air quantity
approx. 80/90 m
3
/h
IP Code (IEC 60529)
IP55
Installation altitude
≤ 2000 m above msl
Sound pressure level
≤ 63 dB(A)
Dimensions (HxWxD):
Approx. 350 x 550 x 500 mm
Weight
Approx. 12 kg
* other voltages and frequencies available on request
The purge air unit is supplied with 10 m of purge air hose Ø 40 mm with a
permissible temperature range – 25 to + 85°C (-13…185°F)..
Table 9.7: Technical data, D-BL xxx purge air unit
9.2.5
9.2.6
Summary of Contents for D-R 290
Page 12: ...12 D R 290 ...
Page 18: ...1 General 18 D R 290 ...
Page 20: ...20 D R 290 ...
Page 28: ...2 Safety 28 D R 290 ...
Page 30: ...30 D R 290 ...
Page 38: ...3 Delivery 38 D R 290 ...
Page 40: ...40 D R 290 ...
Page 60: ...4 Product description 60 D R 290 ...
Page 106: ...106 D R 290 ...
Page 152: ...152 D R 290 ...
Page 174: ...8 Maintenance 174 D R 290 ...
Page 176: ...176 D R 290 ...
Page 178: ...9 Appendix 178 D R 290 Fig 9 2 Measurement point questionnaire 2 ...
Page 194: ...9 Appendix 194 D R 290 ...
Page 200: ...11 Index 200 D R 290 ...
Page 202: ...GmbH Kollaustraße 105 22453 Hamburg Germany www durag com ...