7 | Checking / setting parameters with D‑ESI 100
D-R 290
143
Fig. 7.15: Calibration
After gravimetric calibration of the D‑R 290 a calibration offset and calibration gradient
can be set here.
The relationship between the optical density and dust content, (values are determined
within the gravimetric calibration) is saved in the device by these calibration parame
ters. This allows the direct display of the dust concentration (see section
).
In addition the active measurement path length for calculation of the extinction coeffi
cient and the Koschmieder visual range can be saved (see also section
).
The values for the flange-flange distance (LFF) and the flange length (LF) can also be
saved for reference. If these values are input, the active measurement path length is
calculated automatically, using the formula LA = LFF – 2 × LF.
The stack correction factor can be input for an opacity evaluation according to US
EPA regulations (see section
4.2.5 Calculation of the opacity at the flue stack opening
).
Device status:
The device status shows various parameters which give information about the operat
ing status of the D‑R 290. These include for instance the inner temperatures, status of
the purge air monitoring and status of the fail-safe shutter.
Setting path:
Device (D‑R 290 ) > >
Specific Parameters >
D‑R 290
device status
>
Calibration offset
Calibration gradient
Measuring path length
Flue stack
correction factor
7.7.7
Summary of Contents for D-R 290
Page 12: ...12 D R 290 ...
Page 18: ...1 General 18 D R 290 ...
Page 20: ...20 D R 290 ...
Page 28: ...2 Safety 28 D R 290 ...
Page 30: ...30 D R 290 ...
Page 38: ...3 Delivery 38 D R 290 ...
Page 40: ...40 D R 290 ...
Page 60: ...4 Product description 60 D R 290 ...
Page 106: ...106 D R 290 ...
Page 152: ...152 D R 290 ...
Page 174: ...8 Maintenance 174 D R 290 ...
Page 176: ...176 D R 290 ...
Page 178: ...9 Appendix 178 D R 290 Fig 9 2 Measurement point questionnaire 2 ...
Page 194: ...9 Appendix 194 D R 290 ...
Page 200: ...11 Index 200 D R 290 ...
Page 202: ...GmbH Kollaustraße 105 22453 Hamburg Germany www durag com ...