Duraflame iLLUMA 61020 Owner'S Manual Download Page 1

-1-

Bio-ethanol fireplace burner and 24” log set

Model # 61020

Distributed by:

Duraflame, Inc., Stockton, CA  95201

For questions about Assembly and Operating instructions or Warranty Claims  

contact Duraflame, Inc. Consumer Affairs 

 

[email protected]

 

1 (866) 552-3015

 

www.duraflame.com/illuma

Patents Pending

                Tested to UL 1370 for “unvented bio-ethanol burners” by PFS Corporation

Note: Any reference to Burner or Burners applies to both burners in this entire document.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may 

result, causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 

other appliance.

WHAT TO DO IN THE EVENT OF AN ALCOHOL SPILL: DO NOT light the burner.  Extinguish 

any open flame near the spill.  Wipe up the spill, and wait several minutes for the residue to 

evaporate.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause 

injury or property damage.  Refer to this manual for correct installation and operational 

procedures.

WARNING: This appliance is for installation only in a solid-fuel-burning masonry fireplace, a 

UL127 factory-built fireplace, or in an ANSI Z21.91 ventless firebox.  It is design certified for 

these installations in accordance with UL1370.  Exception: Do not install this appliance in a 

factory-built fireplace that includes instructions stating that it has not been tested or should 

not be used with unvented gas logs.

This appliance may be installed in a fireplace or firebox approved for aftermarket, permanently 

located, manufactured (mobile) homes, where not prohibited by local codes.

This appliance is for use only with duraflame

®

 illuma-fuel

®

 or types of fuel indicated on the 

rating plate.  This appliance is not convertible for use with other fuels, nor should you use 

illuma-fuel

®

 with any product other than duraflame

®

 illuma

®

 log sets.

Save this manual for future reference.

Summary of Contents for iLLUMA 61020

Page 1: ...or the residue to evaporate WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational...

Page 2: ...p 5 III Minimum Firebox Dimensions 6 IV Clearances 7 V Installing Damper Stop 7 VI Installation 7 VII Installing the Fuel Canister 11 VIII Operation 11 IX Refueling 13 X Adjustments 14 XI Maintenance...

Page 3: ...se gasoline Never use this appliance in areas where flammable vapors or gas may be present Never store or transport the fuel in anything other than the original container that it came in Store fuel in...

Page 4: ...he appliance with the glass doors closed Heat buildup within the fireplace could cause the glass doors to break or burst or cause the release of harmful combustion products into the living area If the...

Page 5: ...used for purposes other than that for which it is intended or if it is repaired by unqualified persons II SETUP WARNING This appliance is for use only in a solid fuel burning masonry fireplace a UL12...

Page 6: ...local codes in some areas prohibit the use of vent free heaters However these restriction may only apply to Gas burning vent free heaters and not to ethanol burning vent free appliances this unit is...

Page 7: ...draft i e all combustion emissions go up the chimney is obtained VI INSTALLATION 1 Carefully remove the contents of the carton You should find The burner base Figure 1 Six 6 separate ceramic fiber art...

Page 8: ...edge that the canister tray is touching the inside wall of the front log and the back edge of the canister tray has a gap between it and the back metal wall of the front log see Figure 13 Place the ba...

Page 9: ...front log Figure 3 Logs Figure 6 Showing space between tray and log inside wall on the right Figure 8 Placement of right log Figure 7 Placement of rear log Figure 5 Showing space between tray and log...

Page 10: ...of front middle log Figure 12 All logs properly placed Figure 11 Placement of back middle log Figure 9 Placement of left log Figure 13 Proper placement of front log with a gap between the back of the...

Page 11: ...burner to indicate that the fuel is about to run out You can refuel the appliance at this time see Section IX or let the flame die down VIII OPERATION WARNING If you do not follow these instructions...

Page 12: ...parker because the fuel is evaporating at a higher rate than usual and creates and oxygen free environment around the sparker If that happens either wait for a while for the fuel to cool down or ignit...

Page 13: ...uch in the areas indicated Please note that even though the area indicated in Figure 19 is cool areas of the log closer to the flame will be hot 2 Check the fuel canister and make sure IT IS EMPTY 3 G...

Page 14: ...od performance of this appliance is periodic cleaning at least once per year or more depending on frequency of use and checking for leaks Note that after some time heat might cause the stainless steel...

Page 15: ...rcer are installed properly see Figure 21 The top surface of the piercer should be level If it is higher on the left end then turn it around and place it back in place again 8 Check for leaks by insta...

Page 16: ...rner to the fuel reservoir might be clogged Starting at the tube opening in the bottom of the burner run a thin flexible wire through the length of the tube to remove the obstruction The battery in th...

Page 17: ...Base 61022 Igniter 61023 Front Log 61024 Back Log 61026 Left Log 61025 Right Log 61027 Front Middle Log 61028 Back Middle Log 61007 Canister Tray Piercer 61030 Heat Shield 61031 Grate 61010 Masonry Sc...

Page 18: ...nd or Duraflame Inc which will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Correction in the manner provided above shall constitute...

Page 19: ...the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from st...

Reviews: