DESCRIPTION 
 

The RMF-4012 has an auto range voltage input of 85 to 264 VAC, with 47 to 63 Hz or 120 to 370 VDC. This unit comes with 

three available outputs that are adjustable; these outputs are available in 12, 24, and 48 VDC. All RMF devices have a built-in TTL 
remote control and remote sense along with a DC-OK TTL signal, along with short circuit, over load, over voltage, over temperature 
protections, and hold UL, CE, TUV, CUL approvals. To guarantee DuraComm’s durability DuraComm offers a 3 year warranty for all of 
their RMF series products. 

 

 

SPECIFICATIONS 

 

Output Voltage ....................................................................................................................................................................... 13.8 VDC 
Output Adjustment Range ............................................................................................................................................. 11  to  14.5 VDC 
Output Voltage Tolerance ........................................................................................................................................................ +/- 1 pct 
Output amperage, max continuous ......................................................................................................................................... 45  Amps 
Maximum Power, continuous ................................................................................................................................................ 600  Watts 
Maximum ripple and noise .......................................................................................................................................... 120  mV  p-p max 
Input voltage range (auto-ranging) ..................................................................................................................................... 85-264  VAC 
Input frequency range ............................................................................................................................................................. 47-63 Hz 
Maximum AC current ................................................................................................................. 8.5 Amps/115 VAC; 5 Amps/230 VAC 
Typical Efficiency .......................................................................................................................................................................... 88  % 
Max inrush current, single cycle ...................................................................................... 35  Amps @ 115 VAC, 70 Amps @ 230 VAC 
Overload Protection (operates) ............................................. typical 85 to 115 %, Constant Current Limiting, Recovers Automatically 
Line Regulation ............................................................................................................................................................................ 0.3  % 
Load Regulation ........................................................................................................................................................................... 0.5  % 
Fan Control ........................................................................................................................ LOAD 35+/-15% or RTH2>/=50 C, Fan On 
Over Temperature ....................... +80 C Power Transistor or +100 C Output Choke, Shutdown Output Voltage, Automatic Recovery 
Rise Time following ON (Full Load) ............................................................................................................................................. 50  mS 
Hold Time following OFF (Full Load) ............................................................................................................................................ 16mS 
Working Temperature range ................................................................................................................... -40 to 158 F (-40 C to +70 C) 
Storage Temperature .............................................................................................................................. -40 C to 185 F (-40 to +85 C) 
Withstand Voltage ...................................................................................................................................... 3 KVAC @ 10 ma (I/P-O/P) 
             (Continued)  ................................................................................................................................... 2 KVAC @ 10 ma (I/P-F/G) 