1
LPB-12M
Desktop Power Supply
Owners Guide
(These instructions are intended for use by a technician familiar with electronic products)
•
Universal input 100~264 VAC
•
Short circuit / over load / over temperature protections
•
Built-in EMI filter
•
Front panel power LED
•
Front panel DC voltage and battery level indicator
•
Two front panel USB type A charger outputs, 2 Amps each
•
Internal battery automatically recharges when AC power is
restored
•
Compatible with all LPH Hoods for custom mobile radio
mounting
DESCRIPTION
DuraComm’s LPB-12M power supply is pre-set to convert 100 to 260 volt 50/60 Hz AC power to low noise and ripple 13.8 volt
DC power. The AC input is auto-ranging and can be used without any changes. The power supply also contains a built-in, replaceable
sealed lead acid battery that automatically takes over should AC power be disrupted. The DC output operating voltage from the internal
battery and AC charger circuitry is delivered to the terminal strip located on the rear panel. The from panel meter shows DC voltage
output and battery level. The power supply DC output is protected against inadvertent shorts and overloads by a thermal circuit breaker.
SPECIFICATIONS
Operational DC Voltage ........................................................................................................................................... 13.8 VDC, nominal
Maximum Current, continuous .................................................................................................................. 12 Amps Max / 7 Amps Cont.
AC Input voltage range .................................................................................................................................................... 100-260 VAC
Max inrush current, single cycle ............................................................................. Cold start, 30 Amps / 115 Volts; 60 Amps/ 230 Volts
Overload Protection (operates).................................................................................................................................. DC circuit Breaker
Ripple and noise ................................................................................................................... 150 mV P-P, or less, built-in EMI Filtering
Internal Battery ..................................................................................................................................... rechargeable, sealed lead acid
........................................................................................................................ 12 VDC / 7 Hrs, Powersonic PS-R1270F1 or equivalent
Working Temperature range.............................................................................................................................. -4 - 140 F (-20 - +60 C)
Storage Temperature ...................................................................................................................................... -40 - 185 F (-40 - +85 C)
Size................................................................................................................................................. 3.75H x 7W x 10D inches, nominal
Weight......................................................................................................................................................................... 7.75 lb, nominal
GENERAL APPLICATION NOTES AND WARNINGS
WARNING
:
There are no user serviceable parts inside. Service must be referred to a qualified factory technician or factory
trained technician. DO NOT
OPERATE THE UNIT IN A HOT, ENCLOSED ENVIRONMENT OR COMPARTMENT. BE SURE
ADEQUATE VENTILATION FOR COOLING IS PROVIDED SINCE HEAT BUILD UP WILL SHORTEN COMPONENT LIFE.