DuraComm LPB-12M Product User Manual Download Page 1

 

 

LPB-12M 

Desktop Power Supply 

Owners Guide 

(These instructions are intended for use by a technician familiar with electronic products) 

 

 

 

 

Universal input 100~264 VAC 

 

Short circuit / over load / over temperature protections 

 

Built-in EMI filter 

 

Front panel power LED 

 

Front panel DC voltage and battery level indicator 

 

Two front panel USB type A charger outputs, 2 Amps each 

 

Internal battery automatically recharges when AC power is 

restored 

 

Compatible with all LPH Hoods for custom mobile radio 

mounting 

 

 

 

 

 

DESCRIPTION 

 

DuraComm’s LPB-12M power supply is pre-set to convert 100 to 260 volt 50/60 Hz AC power to low noise and ripple 13.8 volt 

DC power.  The AC input is auto-ranging and can be used without any changes. The power supply also contains a built-in, replaceable 
sealed lead acid battery that automatically takes over should AC power be disrupted.  The DC output operating voltage from the internal 
battery and AC charger circuitry is delivered to the terminal strip located on the rear panel.  The from panel meter shows DC voltage 
output and battery level. The power supply DC output is protected against inadvertent shorts and overloads by a thermal circuit breaker. 

 
 

SPECIFICATIONS 

 
Operational DC Voltage ........................................................................................................................................... 13.8 VDC, nominal 
Maximum Current, continuous .................................................................................................................. 12 Amps Max / 7 Amps Cont. 
AC Input voltage range .................................................................................................................................................... 100-260 VAC 
Max inrush current, single cycle ............................................................................. Cold start, 30 Amps / 115 Volts; 60 Amps/ 230 Volts 
Overload Protection (operates).................................................................................................................................. DC circuit Breaker 
Ripple and noise  ................................................................................................................... 150 mV P-P, or less, built-in EMI Filtering 
Internal Battery  ..................................................................................................................................... rechargeable, sealed lead acid 
 ........................................................................................................................ 12 VDC / 7 Hrs, Powersonic PS-R1270F1 or equivalent 
Working Temperature range.............................................................................................................................. -4 - 140 F (-20 - +60 C) 
Storage Temperature ...................................................................................................................................... -40 - 185 F (-40 - +85 C) 
Size................................................................................................................................................. 3.75H x 7W x 10D inches, nominal 
Weight......................................................................................................................................................................... 7.75 lb, nominal 

 

GENERAL APPLICATION NOTES AND WARNINGS

 

 

WARNING

There  are  no  user  serviceable  parts inside.  Service  must  be referred  to  a  qualified factory technician  or  factory 

trained  technician.  DO  NOT 

OPERATE  THE  UNIT  IN  A  HOT,  ENCLOSED  ENVIRONMENT  OR  COMPARTMENT.  BE  SURE 

ADEQUATE VENTILATION FOR COOLING IS PROVIDED SINCE HEAT BUILD UP WILL SHORTEN COMPONENT LIFE.  

 

 

Reviews: