5.7 Optional attachments

Incremental encoder (RE)

Encoder impulses

500 (other impulse 

counts on request)

Encoder channels 

2

Index impulse 

Yes

Design

Installed in a profile 

housing and mounted on 

rear of motor

Dimensions

65x65 mm, 42.5 mm long

Worm gear (SG)

The worm gears are extremely quiet running. In many 

applications, having the gearbox output shaft at 90° to 

the motor shaft helps to make optimum use of available 

space. On request worm gears can be supplied with a 

hollow output shaft.

Reduction ratio

5:1 … 80:1 

Continuous output torque Max. 30 Nm 

Planetary gears (PLG)

Planetary gears have the highest permissible continuo-

us torque of all types of gearbox and, at the same time 

are very compact, have low weight, and have excellent    

efficiency.

Reduction ratio

3:1 … 710:1

Continuous output torque Max. 160 Nm

Brakes (E)

Brushless DC motors in the BG range can be fitted with 

a power-off or a power-on brake as an option.

6 Types of operation

Among other following types of operation are possible:

- Current/torque mode

- Velocity mode

- Position mode

- SVEL mode

5.7 Optionale Anbauten

Inkrementalgeber (RE)

Geberimpulse

500 (andere Impuls-

zahlen auf Anfrage)

Geberkanäle

2

Indeximpuls

ja

Bauform 

hinten am Motor in Profil

-

gehäuse montiert

Abmessungen 

65x65 mm; 42,5 mm 

lang

Schneckengetriebe (SG)

Die Schneckengetriebe zeichnen sich durch hohe 

Laufruhe aus. Bei vielen Anwendungen ist die um 90° 

gegenüber der Motorwelle versetzte Getriebewelle von 

baulichen Gegebenheiten her optimal. Auf Anfrage sind 

Schneckengetriebe auch mit Hohlwelle lieferbar.

Untersetzungen

5:1 … 80:1

Dauerdrehmomente 

max. 30 Nm

Planetengetriebe (PLG)

Planetengetriebe haben die höchsten zulässigen Dau-

erdrehmomente aller Getriebe bei gleichzeitig sehr 

kompakter Bauform, geringem Gewicht und ausge-

zeichnetem Wirkungsgrad.

Untersetzungen 

3:1 … 710:1

Dauerdrehmomente

max. 160 Nm

Bremsen (E)

Bürstenlose Gleichstrommotren der Baureihe BG kön-

nen optional mit angebauten Ruhe- oder Arbeitsstrom-

bremsen ausgerüstet werden.

6 Betriebsarten

Unter anderem sind folgende Betriebsarten möglich:

- Current/torque mode

- Velocity mode

- Position mode

- SVEL mode

Summary of Contents for BG 65x25 MI

Page 1: ...Edition Ausgabe 05 2010 Instruction Manual Betriebsanleitung Motor with freely programmable motion controller integrated Motor mit integriertem frei programmierbaren Motioncontroller BG 65 MI ...

Page 2: ... Maintenance Service 23 10 1 Maintenance taking out of service and disposal 23 10 2 Service Support 23 10 3 Scope of delivery and accessories 24 10 4 Download PDF Data 24 Seite 1 Inhalt 2 2 Über dieses Dokument 3 3 Allgemeine Beschreibung 4 3 1 Motorbaureihe BG 65 MI 4 3 2 Begriffserklärungen 5 3 3 Bestimmungsmäßige Verwendung 6 4 Sicherheitshinweise 7 5 Technische Daten Zubehör 8 5 1 Elektrische ...

Page 3: ...triebnahme sind unbedingt die Sicherheitshinweise zu lesen und zu beachten Eine Nichtbeachtung kann zu Gefahren bei Personen oder Beschädigungen an der Maschine führen Gerät spannungsfrei schalten To ensure trouble free operation appro piate methods of transport and condi tions of storage must be deployed Please store the drive so that it is protected against dust dirt and moisture Take care of th...

Page 4: ...men erforderlich mögliche weitere Maßnahmen sind Installation von Störfiltern zusätzliche Erdung und Verringerung der Leitungslängen Prüfen Sie vor Inbetriebnahme die elektromagnetische Konfor mität ihrer Anlage bezüglich der notwendigen Anforderungen HINWEIS NOTICE HINWEIS NOTICE To protect the drive against damage or destruction by static discharge ESD the following measures must be observed The...

Page 5: ...ation Organisation www can cia de Lesen und befolgen Sie in diesem Dokument die Warnhinweise sorgfältig Die Warnhinweise sollen Sie vor Gefahr schützen oder helfen Ihnen eine Beschädigung des Gerätes zu vermeiden HINWEIS Read and observe the warnings in this dokument Warnings are there to protect you from danger and to help you to avoid damage to the device NOTICE Hinweise erläutern Ihnen Vorteile...

Page 6: ...nlose DC Servomotoren mit einem integrierten frei programmierbarem Motioncontroller und CAN Bus Schnittstelle CANopen Drives Profil DSP 402 Die integrierte MPU Motion Process Unit ermöglicht das Abspeichern eines Programmes und somit den Stand alone Betrieb oder auch die Darstellung von Stand alone Netzwerken Somit ist dieser speicher programmierbare Antrieb als Netzwerk bzw Bus Ma ster einsetzbar...

Page 7: ...r a higher level positioning system e g a CNC control system Torque mode Torque regulation also referred to as Current Mode Trajectory Sequence of motions Velocity mode Speed regulation 3 2 Begriffserklärungen Baud rate Übertragungs Kommunikati onsgeschwindigkeit Bus Kommunikationsnetzwerk bei dem alle Knoten über passive Links erreicht werden können und Kommunikation in beide Richtungen möglich i...

Page 8: ...ied by Dunkermotoren The drive may only be put into service after the complete system has been installed with due attention to EMC aspects 3 3 Bestimmungsmäßige Verwendung Der BG 65 MI ist ein Zulieferteil und darf in der beschriebenen Konfiguration in Maschinen und Anlagen eingesetzt werden industrieller Bereich Der Antrieb muss fest montiert werden und darf nur mit den von Dunkermotoren spezifiz...

Page 9: ...ng it is essential that the safety instructions in the relevant section are read and understood and then observed Non observance can result in danger to persons or damage to the machine Disconnect the electrical power supply Vor der Inbetriebnahme sind unbe dingt die Sicherheitshinweise zu lesen und zu beachten Eine Nichtbeach tung kann zu Gefahren bei Personen oder Beschädigungen an der Maschine ...

Page 10: ...en the shaft seals provide adequate protection against dust and water can the drive be used in an environment which calls for IP65 5 Technische Daten Zubehör 5 1 Elektrische Daten Zulässiger Drehzahlbereich 0 6000 rpm Zulässige Motorspannung 10 48 VDC Unterspannungsabschaltung 8 VDC Überspannungsabschaltung der Endstufe 50 VDC Absolut zulässige Steuerspannung 19 2 28 8 VDC Zulässige Restwelligkeit...

Page 11: ...ominal voltage 24 V standard special voltages on request Nominal current 4 A Dimensions without connector 65x65 mm 115 mm long without incremental encoder Weight Ca 950 g 5 3 Motormaßzeichnung 5 4 Motor BG 65x25 MI Nennleistung 65 W Nenndrehmoment 17 21 Ncm Nenndrehzahl 3100 Empfohlener Drehzahl bereich 30 5000 rpm mit Hall sensoren 1 5000 rpm mit optio nalem Inkrementalgeber Nennspannung 24 V Sta...

Page 12: ...d For this reason the nominal torque is quoted to VDE EN and also measured with a thermally con ducting steel plate with the dimensions 105 x 105 x 10 mm attached to the motor 5 5 Motor BG 65x50 MI Nennleistung 100 W Nenndrehmoment 26 31 Ncm Nenndrehzahl 3100 Empfohlener Drehzahl bereich 30 5000 rpm mit Hall sensoren 1 5000 rpm mit optio nalem Inkrementalgeber Nennspannung 24 V Standard Sonderspan...

Page 13: ...ower on brake as an option 6 Types of operation Among other following types of operation are possible Current torque mode Velocity mode Position mode SVEL mode 5 7 Optionale Anbauten Inkrementalgeber RE Geberimpulse 500 andere Impuls zahlen auf Anfrage Geberkanäle 2 Indeximpuls ja Bauform hinten am Motor in Profil gehäuse montiert Abmessungen 65x65 mm 42 5 mm lang Schneckengetriebe SG Die Schnecke...

Page 14: ...r Zerstörung z B bei extremer Belastung oder bei Spannungsüberhöhungen 7 1 Ballastschaltung Bei Bremsvorgängen wird die kinetische Energie als elek trische Energie in den Zwischenkreis des Regelkreises zurückgeführt Dabei kann es im Zwischenkreis zu Span nungsüberhöhungen kommen die im Extremfall Schäden an elektrischen Bauteilen verursachen können Um dies zu vermeiden sollten DC Netzteile mit Brü...

Page 15: ...ent torques can be achie ved for starting and continuous operation the current parameters can be dynamically adapted by the master system to suit the drive situation 7 3 Strombegrenzung Um den Motor als auch die Anlage vor Blockierung oder Überlastung zu schützen sind die Parameter für die Strombegrenzung einzustellen die als Dauerstrombe grenzung wirkt Hinweis Um unterschiedliche Momente für Anla...

Page 16: ...die ent sprechenden Daten der Dokumentation zum Getriebe zu entnehmen 8 2 Elektromagnetische Verträglichkeit Beim Antrieb BG 65 MI und bei der Maschine in welche der Antrieb eingebaut wird entstehen elektromagne tische Störstrahlungen Diese können ohne geeignete Schutzmaßnahmen die Signale von Steuerleitungen und Anlageteilen beeinflussen und die Betriebssicherheit der Anlage gefährden Vor dem Bet...

Page 17: ...er Series 723 The 12 pin motor connector supplies power for the mo tor and a 24V supply for the control electronics 8 4 Leistungsversorgung Motor und Schnittstellenversorgung Motorstecker Rundstecker nach DIN 45326 Fa Binder Serie 723 Der 12 polige Motorstecker dient zur Spannungsver sorgung des Motors und zur Spannungsversorgung und Logikversorgung mit 24 V für die Regelelektronik F H G M A E D K...

Page 18: ...input IN4 magenta A OUT1 Digital output OUT1 orange K OUT2 Digital output OUT2 white Lead colours refers to standard connection cables of Dunkermotoren Stecker Pin Anschluß Funktion Litzenfarbe der Anschluß leitung mit 12pol Winkel stecker E F UE 24 42V DC Motorver sorgung rot 1mm2 D UC UC 24V Logik versorgung grün M G PGND PGND 0V schwarz 1mm2 B IN0 Digitalein gang IN0 gelb C IN1 Digitalein gang ...

Page 19: ...it Anschlußleitung bitte mitbestellen Für die Motoren BG65MI mit seitlichem 12 poligem Anschlußstecker stehen passende vorkonfektionierte Anschlußleitungen in verschiedenen Längen ab Lager zur Verfügung Die Leitungen sind auf einer Seite mit einer entsprechenden 12 poligen Winkeldose anschlußfertig konfektioniert Auf der anderen Seite sind die Leitungen glatt abgeschnitten Die Leitungen haben eine...

Page 20: ...leitung BG 65 MI Version 1 3 en_de 2010 Dunkermotoren GmbH D 79848 Bonndorf Germany Standard angled positions not adjustable Option angeld position adjustable Standard Winkelposition nicht einstellbar Option Winkelposition einstellbar ...

Page 21: ...nnungs quelle ist ein sicherer Betrieb nicht immer gewährleistet Die Folge Unterspannungsabschaltung oder Motor Reset Maximale Kabellänge beachten If the supply of power and logic electronic is procceded by a common 24V DC power source a safe operation is not always guaranteed Possible consequence Low voltage cut off or motor reset Mind the maximum cable length CAUTION VORSICHT Type of motor Motor...

Page 22: ...E512PG9 Art No 933040 100 Mating connector with cable not in scope of supply Lumberg Type 0935 253 103 Cable length Order number 1m 16597 57014 8m 16597 57016 8 8 CAN Feldbusanschluss Motorstecker Rundstecker M12 Fa Binder Serie 763 Art Nr 09 3443 00 05 Stecker Pin Anschluß 1 n c 2 n c 3 n c 4 CAN H 5 CAN L Gegenstecker nicht im Lieferumfang enthalten Fa Hirschmann Typ ELKE512PG9 Art Nr 933040 100...

Page 23: ...evant section are read and understood and then observed Non observance can result in danger to persons or damage to the machine Disconnect the electrical power supply Vor der Inbetriebnahme sind unbe dingt die Sicherheitshinweise zu lesen und zu beachten Eine Nichtbeach tung kann zu Gefahren bei Personen oder Beschädigungen an der Maschine führen Gerät spannungsfrei schalten WARNING WARNUNG Falsch...

Page 24: ...n muß der Einschaltstrom über eine Softstartfunktion rea lisiert werden Das kann entweder durch entspre chende Wahl eines Netzteiles oder wie im nachfol genden Prinzipschaltbild erfolgen Der grau hinterlegte Ausschnitt des Prinzipschaltbildes zeigt die exakten Anschlüsse eines BG65 MI Es können auch mehrere BG Motoren wie dargestellt hintereinander geschaltet werden 1 Der anschließende nicht grau ...

Page 25: ...Fax 49 7703 930 210 E Mail info dunkermotoren de 10 Wartung Service 10 1 Wartung Ausserbetriebsetzung und Entsorgung Wartung Dieser Antrieb benötigt keine Wartung Die Getriebe sind lebensdauergeschmiert Wenden Sie sich im Stör fall direkt an uns und lassen Sie Reparaturen am An trieb nur von Dunkermotoren durchführen Ausserbetriebsetzung Entsorgung Setzen Sie den Antrieb ausser Betrieb s o Demon t...

Page 26: ... Version 1 3 en_de 2010 Dunkermotoren GmbH D 79848 Bonndorf Germany 10 3 Scope of delivery and accessories As quoted 10 4 Download PDF Data www dunkermotoren de 10 3 Lieferumfang und Zubehör Wie angeboten 10 4 Download PDF Daten www dunkermotoren de ...

Page 27: ...25 Instruction Manual Betriebsanleitung BG 65 MI Version 1 3 en_de 2010 Dunkermotoren GmbH D 79848 Bonndorf Germany Notes Notizen ...

Page 28: ...26 Instruction Manual Betriebsanleitung BG 65 MI Version 1 3 en_de 2010 Dunkermotoren GmbH D 79848 Bonndorf Germany Notes Notizen ...

Page 29: ...27 Instruction Manual Betriebsanleitung BG 65 MI Version 1 3 en_de 2010 Dunkermotoren GmbH D 79848 Bonndorf Germany Notes Notizen ...

Page 30: ......

Reviews: