Service Manual for
RCO Speed Oven
#
NAME
DESCRIPTION
SETTING DEF SETTING/RANGE
Motor
Parameters
E1-01 Input Voltage
Setting
This parameter must be set to the
power supply voltage.
230
230 155 to 255 V
E1-03 V/f Pattern
Selection
000F
000F F: Custom V/f. E1-04 through E1-10
settings define the V/f pattern.
E1-04 Max Output
Frequency
To set linear V/f characteristics,
set the same values for E1-07 and
E1-09. In this case, the setting for
E1-08 will be disregarded. Ensure
that the four frequencies are set
according to these rules: E1-04 ≥
E1-06 > E1-07 ≥ E1-09
63.5
60.0
40.0 to 400.0 Hz
E1-05 Max Output
Voltage
230.0
230.0 0.0 to 255.0 V
E1-06 Base Frequency
60.0
60.0
0.0 to E1-04 Hz
E1-07 Mid Output
Frequency
1.5
3.0
0.0 to E1-04 Hz
E1-08
Mid Output
Frequency
Voltage
12.0
18.4 0.0 to 255.0 V
E1-09 Minimum Output
Frequency
1.5
1.5
0.0 to E1-04 Hz
E1-10
Minimum Output
Frequency
Voltage
12.0
13.8 0.0 to 255.0 V
E2-01 Motor Rated
Current
2.40
1.90 10 to 200% of drive rated current
(A)
E2-02 Motor Rated Slip
2.50
2.90
0.00 to 20.00 Hz
E2-03 Motor No-Load
Current
1.49
1.20 0 to less than E2-01 (A)
E2-05 Motor Line-to-Line
Resistance
9.842
9.842
0.000 to 65.000 Ω
Multi-
Function
Terminals
H1-01
Multi-Function
Digital Input
Terminal S1
Function
Selection
Assigns a function to the multi-
function digital inputs. Refer to
H1 Multi-Function Digital Input
Selections on page 200 of the
Quick Start Guide (included with
inverter) for a description of setting
values.
0040
0040
1 to 67
H1-02
Multi-Function
Digital Input
Terminal S2
Function
Selection
0041
0041
H1-03
Multi-Function
Digital Input
Terminal S3
Function
Selection
0024
0024
H1-04
Multi-Function
Digital Input
Terminal S4
Function
Selection
0014
0014
H1-05
Multi-Function
Digital Input
Terminal S5
Function
Selection
0003
0003
H2-01
Terminal MA, MB
and MC Function
Selection (relay)
Refer to H2 Multi-Function Digital
Output Settings on page 202 of the
Quick Start Guide (included with
inverter) for a description of setting
values.
0000
000E 0 to 13D