Duke HSHU 13 SERIES Installation And Operation Manual Download Page 1

U.S. Patent 6175099, 6262394

Other U.S. and Foreign

Patents Pending

Installation and

Operation Manual

MODEL 
HSHU 13 SERIES

HSHU 22 SERIES

HSHU 23 SERIES 

HSHU2 22 SERIES

HSHU

(HEAT SINK 

HOLDING UNIT)

P/N 158270

REV L 10/30/2017

This manual is Copyright © 2017 Duke Manufacturing Co. All rights reserved.  

Reproduction without written permission is prohibited. Duke is a registered  

trademark of the Duke Manufacturing Co.

Duke Manufacturing Co.

2305 N. Broadway

St. Louis, MO 63102

Phone: 314-231-1130

Toll Free: 1-800-735-3853

Fax: 314-231-5074

www.dukemfg.com

 

CAUTION:

Please read this manual completely before attempting 

to install, operate or service this equipment

Summary of Contents for HSHU 13 SERIES

Page 1: ...his manual is Copyright 2017 Duke Manufacturing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufactur...

Page 2: ...Installation and Operation of HSHU 2...

Page 3: ...f HSHU TABLE OF CONTENTS Important Safety Instructions 4 Unit Specifications 7 Electrical Connection 11 Installation 12 Operation 13 Cleaning Instruction 16 Troubleshooting 17 Parts Lists aand Explode...

Page 4: ...ode and or other local electrical codes Failure to comply with this procedure can cause property damage injury or death Before connecting the unit to the electrical supply verify that the electrical c...

Page 5: ...able vapors or liquids in the vicinity of this or any other appliance Failure to comply can cause property damage injury or death In the event of a power failure do not attempt to operate this applian...

Page 6: ...ap waste The self contained individually formed sealed compartments of the HSHU eliminates food odor and tastetransfer Becausethecompartmentsaresealedandformedtotheshapeofthepan nodisassembly is requi...

Page 7: ...3112 AUS L6 20P Twist Lock Plug 208 240V US CAN CEE 7 7 STD SHEET C4 230V GERMAN AND FRENCH CE UNITS IEC 60309 3 Pin Sleeve Plug 230V UK CE UNITS TOP 25 7 8 65 6cm 12 30 5cm 32 1 2 82 4cm Compliance D...

Page 8: ...Plug 208 240V US CAN IEC 60309 3 Pin Sleeve Plug 230V UK CE UNITS 2 6cm 3 1 7 7cm 1 3 8 3 5cm 25 7 8 65 6cm 12 30 5cm 46 1 2 118 2cm Compliance Declaration Standard UL197 File KNGT E17421 Standard CS...

Page 9: ...ck Plug 208 240V US CAN TOP 16 40 64 cm 12 30 5 cm 32 1 2 82 4 cm Compliance Declaration Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E1574...

Page 10: ...V 7 9 A 7 9A 1800 W 50 Hz Compliance Declaration Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A...

Page 11: ...the unit to the electrical power source 4 Atthecircuitbreaker turnonpowertothecircuit If the supply cord is damaged it must be replaced by a special cord or a special cord assembly availablefromDukeMa...

Page 12: ...e with the following 1 State and local codes 2 National Electrical Code ANSI NFPA No 70 latest edition available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 3 Vapor...

Page 13: ...ection of themanualforinstructionsonusingandprogramming the keypad A B C Use these procedures to shut the unit down 1 Place the Power Switch in its OFF position 2 Remove all pans 3 Allow the cabinet t...

Page 14: ...ct presentinanotherpan thenStatusLEDwillremain non illuminated andPanDisplayalternatelyshows Time Remaining and Product Name 3 Att cooktimetheStatusLEDbeginsFLASHING alarm sounds and Display alternate...

Page 15: ...s unitwillacceptnewtimeandreturntonormal operation Note Time cannot increment beyond programmed hold time Menu Mode This option is used to change Meal Set and view Linking Hold Time and Hold Temp Ente...

Page 16: ...approximately 30 minutes 5 Wipe down interior and exterior of the cabinet with warm water and mild detergent using a soft cloth 6 Clean pans using mild detergent and warm water 7 Ensure all soap is ri...

Page 17: ...damage To remove heat tint follow the routine cleaning procedure Stubborn heat tint will require heavy duty cleaning To reduce heat tint limit the exposure of equipment to excessive heat TROUBLESHOOT...

Page 18: ...ace temperature probe to measure temperatures 2 per pan 2 No pans should be in wells during the pre heat and temperature check Pre heat the warmer for 30 minutes before taking any temperature readings...

Page 19: ...19 Installation and Operation of HSHU THIS PAGE LEFT BLANK...

Page 20: ...8360 Wiring Diagram Hshu 23 1 158559 Wiring Diagram Hshu 13 1 4 157886 Switch 1 1 1 156527 Switch 1 5 156195 Usb Host Adapter 1 1 1 1 6 155749 Transformer 208 240V 1 1 1 1 156838 Transformer 230V 1 1...

Page 21: ...HU 22 MAIN CABINET EXPLODED VIEW FOR REFERENCE ONLY UNIT TO BE SERVICED BY AUTHORIZED PERSONNEL ONLY PARTS LISTS EXPLODED VIEWS continued DETAIL A 4 5 SEE CONTROLS PAGE 2 3 1 SEE HEATER LINER ASSY PAG...

Page 22: ...edium Lead 1 2 1 2 C 158312 Thermostat 1 1 1 1 2 158282 Assy Heat Sink HSHU 33 Lead 2 1 2 A 158276 Element 208V 300W 33 Lead 1 2 A 158330 Element 230V 300W 33 Lead 1 2 B 158279 RTD Medium Lead 1 2 1 2...

Page 23: ...23 Installation and Operation of HSHU HSHU 22 LINER ASSEMBLY EXPLODED VIEW CONTROL SIDE 1 2 C A B PARTS LISTS EXPLODED VIEWS continued...

Page 24: ...Y AUTHORIZED PERSONNEL ONLY CONTROLS HSHU 22 SHOWN ITEM PART NO DESCRIPTION QTY HSHU 22 HSHU 23 HSHU2 22 HSHU 13 1 158284 RTD Board 1 1 1 1 158337 RTD Board CE 1 1 1 1 2 157743 Terminal Block 8 TAB 1...

Page 25: ...EC PRIMARY TERMINAL BLOCK WHT BLK WHT RED BLK YEL RED 1F 1R 3F 3R 5F 5R 6R 6F 4R 4F 2R 2F BLK BLK BLK BLK WHT WHT WHT WHT WHT 2F BLK 1F BLK 4F 1R BLK 2R BLK 3R 4R BLK BLK BLK WHT BLK WHT BLK WHT BLK W...

Page 26: ...INAL BLOCK WHT BLK WHT RED BLK YEL RED 1F 1R 3F 3R 5F 5R 6R 6F 4R 4F 2R 2F BLK BLK BLK BLK BLK BLK WHT WHT 6R BLU WHT WHT WHT WHT 2F RED 1F RED BLK 4F BLK 5F 6F 3R BLK 4R BLK 1R RED 2R RED 5R 6R BLK B...

Page 27: ...IMARY TERMINAL BLOCK WHT BLK WHT RED BLK YEL RED 1F 1R 3F 3R 5F 5R 6R 6F 4R 4F 2R 2F BLK BLK BLK BLK WHT WHT 3F BLK 1F RED RED 3R BLK 5R WHT 5F WHT BLK BLK BLK WHT BLK WHT BLK WHT 5F B LK 5R WHT RED 4...

Page 28: ...Installation and Operation of HSHU 28 Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg com...