DIP-SWITCH - FUNCTIONS
OFF
ON
DIP1
BI-DIREZIONAL LEARNING
Start the BI-DIRECTIONAL learning procedure to pair the siren with control
panel. Complete the procedure starting the same operation on control panel.
Normal working
Learning
DIP2
“BY DETECTION” LEARNING
Starts the “by detection” learning to pair the siren with control panels without
the BI-DIRECTIONAL function.
The siren emits some times its TAMPER radio code (which must be learned int
radio zone memory of the panel) then listens for control panel radio code in
order to store it.
Normal working
Learning
(press the temper
switch to start)
DIP3
SUPERVISION
The siren sends a special “in life” radio code to inform the control panel of its
correct working and presence.
The supervision code is transmitted after about 1 hour from last transmission.
The supervision enabled causes higher battery consumption.
Supervision off
Supervision on
DIP4
ALARM BLOCK (COUNTER)
The siren sounds for max 5 alarms (each alarm sound lasts about 1 minute)
during the same arming, then stops the sounds until the next arming.
It is possible to disable the alarm counting and make the siren sound without
limits.
Block Enabled
Block Disabled
DIP5
LIGHT ALERTS AT ARMING AND DISARMING
The lamp LEDs light on at the arming and disarming of the system to give a
visual feedback to the user:
TOTAL ARMED > long blink
PARTIAL 1 > long blink + 1 short
PARTIAL 2 > long blink + 2 short
PARTIAL 3 > long blink + 3 short
DISARMED > three blinks
Disable this function if this signalling is not used.
The light alerts enabled causes higher battery consumption.
Alerts ON
Alerts OFF
DIP6
NOT USED
Leave OFF
-
DIP7
NOT USED
Leave OFF
-
DIP8
NOT USED
Leave OFF
-
4.
RESET
It is possible to reset the siren to factory settings with the following steps:
1.
Unplug the battery
2.
Set
all DIPs
to
ON
3.
Connect the battery: the siren emits some “BEEP” and LED blinking
4.
Unplug the battery and set all DIPs to OFF, the start with new programming