background image

DUDLEY

ILLUSION A  

WITH

Specifically designed for wall hung pans, can be sited on a flat wall, in a 

corner or used within furniture.

INSTALLATION INSTRUCTIONS

230mm

180mm

820 - 1

120mm

0 - 150mm

498mm

FLOOR LEVEL

FIXING LEVEL

Foot rotational locking screw 
at end of adjustable leg 

B

Notes -
- Pan outlet connector and soil pipe seal to be purchased 
  separately. Required diameter 110mm

Fig 1

PAN PROTECTION 
BUSH SUPPORT

M12 FULL NUT,

& FLAT WASHER

DECORATIVE CAP

PAN

FRAME

M12 ALLTHREAD

DISHED WASHER

R325586   (11987 - ISSUE  A)   

Thomas Dudley Ltd. 2012.

1. 

    To adjust the height of the frame slacken off the bolts holding the adjustable
     legs in frame      . Adjust the lower section of the frame so that the WC pan 
     rim is 400mm above the floor level. Re-tighten the bolts clamping the 
     frame into position. The feet can be rotated, into any position to suit 
     installation, by using the screw at the foot of the leg        . Adjust the top
     section of the frame to the required height and re-tighten the bolts.

2.  Fit wall straps to frame.
     

The wall straps       can be adjusted and used in any orientation dependant

     on the depth of installation required. Minimum depth is 150mm, maximum 
     depth is 370mm. Once positioned attach firmly to the frame using the M8 
     bolts, nuts and washers provided. 

3.  Fixing to wall and floor.

     Attach frame securely to wall and floor using the plugs, washers and hex 
     head screws provided. See diagrams overleaf for corner fitting. It is the
     responsibility of the installer to ensure that these fixings in the wall and floor 
     are strong enough to adequately support the load which will be applied to 
     the pan in use. It is recommended that fixings are as close as possible to the 
     horizontal part of the brackets.

4.

  

Fitting flushpipe.

     Cut the vertical section of the pipe to the required length, ensuring the pipe is 
     cut straight. Push the flushpipe onto the spigot of the Vantage cistern and 
     secure in place using clamp      . Cut the horizontal section of the pipe to the 
     required length. When installing the frame at its maximum height use the 
     flushpipe extension piece       supplied.

5.  Fitting pan connector.

     Fit a pan connector or soil pipe to clamp       and position to suit the pan being 
     fitted. When in the correct position, complete plumbing to the soil piping.

6.  Fitting Partition.
     

Fit Partition/Wall/Furniture prior to fitting Pan.

7.  Fitting pan.

     Ensure M12 allthread protrudes sufficiently for correct and secure installation 
     of the pan. See fig. 1 for installation detail. 

      

Set frame height .

A

B

C

D

E

F

Clamping bolts at rear of uprights

Vantage
Mounting
Brackets

E

D

C

C

F

A

A

A

Reviews: