Dubaco DS-210 Series User Manual Download Page 1

 

 

 

                         

     

                                DS-210 
 
Handheld Short Range CCD Scanner 
                                               
                          User’s Manual

 

Summary of Contents for DS-210 Series

Page 1: ...DS 210 Handheld Short Range CCD Scanner User s Manual...

Page 2: ...er Tone 11 Power On Tone 11 Good Read Beep 11 Character Installation 12 Other Installation 15 Scanning Verify 15 Bar Space Seting 15 Laser Data Speed Up 15 BAR CODE INSTALLATION 16 UPC A 16 UPC E 18 E...

Page 3: ...Keyboard RS 232 USB Keyboard Terminal Type End PC AT PS 2 IBM PS 2 30 80 PS 2 25 30 IBM XT IBM 5550 NEC 9801 End Language USA Spanish Germany Italian French Japan Keyboard Wedge function Function Key...

Page 4: ...0 Caps Lock ON OFF Num Lock ON OFF Appendix A 00H 64H Inter message Delay Default 00 Appendix A 00H 0AH Delay time set up data 100 ms Keyboard Speed Default 00 Appendix A 00H 08H End Enter End Message...

Page 5: ...op Bits 1 2 Parity None Even Space Odd Mark RS 232 Function Installation Inter character Delay Default 00 Appendix A 00H 64H Inter message Delay Default 00 Appendix A 00H 0AH Delay time set up da ta 1...

Page 6: ...End Handshaking Protocol None ACK NAK RTS CTS Xon Xoff Scan Mode Tigger On Off Continuous Tigger Off Continuous LED always On Flash On Tigger On Good read off Testing Continuous Timeout Off Continuous...

Page 7: ...find the format as below The process for adding the first and last character to the bar code 1 Scan the barcode of Start Configuration and The Preamble Character Installation 2 Check the ASCII table...

Page 8: ...Character Insertion Default 00 Appendix A G2 Character Insertion Default 00 Appendix A 1 Scan the barcode of the Start Configuration and G1 character insertion position 2 Check the ASCII table to get...

Page 9: ...erify Single Double Bar Space Setting Bar High Bar Low Laser Data Speed Up On Off UPC A Reading On Off Code ID Default F 20H 7EH UPC A convert to EAN 13 On Off Transmit Check Character On Off Truncate...

Page 10: ...runcate Last Digit Default 00 00H 0DH Select Insertion Default 00 00H 02H Add On 2 5 2 digit 5 digit 2 or 5 digit None UPC E Reading On Off Code ID Default G 20H 7EH UPC E convert to UPC A On Off Tran...

Page 11: ...00H 08H Select Insertion Default 00 00H 02H Add On 2 5 2 digit 5 digit 2 or 5 digit None EAN 13 Reading On Off Code ID Default H 20H 7EH Transmit Check Character On Off Truncate Leading Digit Default...

Page 12: ...2 or 5 digit None ISBN ISSN Convert On Off EAN 8 Reading On Off Code ID Default I 20H 7EH Transmit Check Character On Off Truncate Leading Digit Default 00 00H 08H Truncate Last Digit Default 00 00H...

Page 13: ...End End Enter Enter Add On 2 5 2 digit 5 digit 2 or 5 digit None Code 39 Reading On Off Code ID Default J 20H 7EH Verification On Off Transmit Check Character On Off Checksum On Off 23 24...

Page 14: ...e39 Full featured Code39 Transfer Start End Character On Off Truncate Leading Digit Default 00 00H 32H Truncate Last Digit Default 00 00H 32H Select Insertion Default 00 00H 02H Codabar Reading On Off...

Page 15: ...0 00H 7EH Select Insertion Default 00 00H 02H Start End Character Type ABCD ABCD abcd to e abcd abcd Transmit Start End Character On Off Min Length Default 00 00H 3CH Max Length 00H 3CH Code93 Reading...

Page 16: ...02H Truncate Leading Digit Default 00 00H 7EH Truncate Last Digit Default 00 00H 7EH Min Length Default 00 00H 50H Max Length Default 00 00H 50H Code 128 Reading On Off Code ID Default M 20H 7EH Verif...

Page 17: ...ading Digit Default 00 00H 7FH Truncate Last Digit Default 00 00H 7FH Select Insertion Default 00 00H 02H Min Length Default 00 00H 7FH Max Length Default 00 00H 7FH UCC EAN128 On Off FNC1 Transmit On...

Page 18: ...e ID Default N 20H 7EH Verification On Off Transmit Check Character On Off Truncate Leading Digit Default 00 00H 7FH Truncate Last Digit Default 00 00H 7FH Select Insertion Default 00 00H 02H Min Leng...

Page 19: ...ID Default O 00H 7EH Verification On Off Transmit Check Character On Off Truncate Leading Digit Default 00 00H 32H Truncate Last Digit Default 00 00H 32H Select Insertion Default 00 00H 02H Min Lengt...

Page 20: ...ode ID Default P 20H 7EH Verification On Off Transmit Check Character On Off Truncate Leading Digit Default 00 00H 50H Truncate Last Digit Default 00 00H 50H Select Insertion 00H 02H Min Length Defaul...

Page 21: ...ID Default Q 20H 7EH Verification On Off Transmit Check Character On Off Truncate Leading Digit Default 00 00H 50H Truncate Last Digit Default 00 00H 50H Select Insertion Default 00 00H 02H Min Length...

Page 22: ...0H 7EH Verification Off MOD 10 MOD 11 10 MOD 10 10 Transmit Check Character On Off Truncate Leading Digit Default 00 00H 3CH Truncate Last Digit Default 00 00H 3CH Select Insertion Default 00 00H 02H...

Page 23: ...Transmit Check Character On Off Truncate Leading Digit Default 00 00H 0AH Truncate Last Digit Default 00 00H 0AH Select Insertion Default 00 00H 02H Code 11 Reading On Off Code ID Default T 20H 7EH Ve...

Page 24: ...Leading Digit Default 00 00H 50H Truncate Last Digit Default 00 00H 50H Select Insertion 00H 02H Min Length Default 00 00H 50H Max Length Default 50H 00H 50H Enter Enter End End APPENDIX A ASCII Confi...

Page 25: ...Enter Enter End End ASCII Table APPENDIX B Function Key Table 47 48...

Page 26: ...tion Key Code Before Scanning Please Turn on the CODE 39 UP A F1 Q DOWN B F2 R LEFT C F3 S RIGHT D F4 T PAGE UP E F5 U PAGE DOWN F Enter End F6 V F7 W BS H F8 X TAB I F9 Y F10 Z HOME K ESC A END L F11...

Page 27: ...Enter End F13 D INSERT N F14 E DELETE O ENTER M 51...

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Reviews: