Maintenance
4-15
Changing the waste roll
Follow the description below when changing a waste roll. For change of nonwoven and PET rolls please
refer to the "Changing nonwoven (NW) and PET rolls" on page 4-7.
WARNING:
Refer to the "Safety precautions" on page 0-9 and the separate Safety Instruction
Manual part No 21741 .
WARNING:
Wear safety protection, e.g. safety shoes, when handling the heavy rolls.
Tools required
•
Translyft or other lifting device. Please see detailed description of operating the "Translyft lift table" on
page 2-17.
NOTE:
The lifting device is an optional extra.
•
Pair of scissors or stanley knife.
•
Double-side self-adhesive heat resistant tape (e.g. Tesa 4965 (50 mm/2"), heat resistant up to 200 °C
transient/100 °C prolonged).
•
Duct tape.
Procedure
1.
Open the rear cover.
2.
Dismount the air compression hose for the
air shaft on the right side of the roll: pull the
lock ring of the quick release coupling
upwards to release the air pressure.
Release the lock ring, then lift the entire
coupling upwards to remove.