RDM – DMX – Manual
Ver. 1.01
19 di 47
ALCHEMY 7
7 Error Messages
ERROR SHOWN ON DISPLAY
APPEARS WHEN
PAN
-Pan motor fault
-Pan encoder fault
-Pan motor driver on Pan&Tilt PCB fault
-Wiring connection between Pan encoder and Pan&Tilt PCB fault
PAN LOCKED
-Pan locked
-Pan motor fault
-Pan encoder fault
-Pan motor driver on Pan&Tilt PCB fault
-Wiring connection between Pan encoder and Pan&Tilt PCB fault
TILT
-Tilt motor fault
-Tilt encoder fault
-Tilt motor driver on Pan&Tilt PCB fault
-Wiring connection between Tilt encoder and Pan&Tilt PCB fault
TILT LOCKED
-Tilt locked
-Tilt motor fault
-Tilt encoder fault
-Tilt motor driver on Pan&Tilt PCB fault
-Wiring connection between Tilt encoder and Pan&Tilt PCB fault
PAN ZERO SENSOR LINE
-Pan magnet missing
-Pan hall sensor PCB fault
-Wiring connection between Pan hall sensor PCB and Pan&Tilt
PCB fault
TILT ZERO SENSOR LINE
-Tilt magnet missing
-Tilt hall sensor PCB fault
-Wiring connection between Tilt hall sensor PCB and Pan&Tilt
PCB fault
DATA ERROR
Pan&Tilt PCB Eeprom data corrupted
TEMP. LED MOD.
LED module temperature detected under -20°C or over 85°C.
Unit immediately goes in black-out.
TEMP. LED1 DRV 1
Output from 1 to 4 LED Driver PCB 1 (Master)* temperature
detected under -20°C or over 100°C. Unit immediately goes in
black-out.
TEMP. LED1 DRV 2
Output from 5 to 8 LED Driver PCB 1 (Master)* temperature
detected under -20°C or over 100°C. Unit immediately goes in
black-out.
TEMP. LED2 DRV 1
Output from 1 to 4 LED Driver PCB 2 (Slave)* temperature
detected under -20°C or over 100°C. Unit immediately goes in
black-out.
TEMP. LED2 DRV 2
Output from 5 to 8 LED Driver PCB 2 (Slave)* temperature
detected under -20°C or over 100°C. Unit immediately goes in
black-out.
TEMP. LED1 MICRO
Micro controller on LED Driver PCB 1 (Master)* temperature
detected under -20°C or over 85°C. Unit immediately goes in
black-out.
TEMP. LED2 MICRO
Micro controller on LED Driver PCB 2 (Slave)* temperature
detected under -10°C or over 85°C. Unit immediately goes in
black-out.
TEMP. 5M1
Micro controller on 5 Motors PCB (1)* temperature detected
over 85°C.
TEMP. 5M2
Micro controller on 5 Motors PCB (2)* temperature detected
over 85°C.
TEMP. 5M3
(only ALCHEMY 7F)
Micro controller on 5 Motors PCB (3)* temperature detected
over 85°C.
MOTOR SUPPLY TOO LOW
PCBs input voltage <46,5Vdc.
MOTOR SUPPLY TOO HIGH
PCBs input voltage >49,5Vdc.
BUS 5 MOTORS CARD 1
-Pan&Tilt PCB driver fault
-5 Motors PCB (1) driver fault
-5 Motors PCB (1) input voltage missing
-Internal Bus wiring connection fault
BUS 5 MOTORS CARD 2
-Pan&Tilt PCB driver fault
-5 Motors PCB (2) driver fault
-5 Motors PCB (2) input voltage missing
-Internal Bus wiring connection fault
BUS 5 MOTORS CARD 3
(only ALCHEMY 7F)
-Pan&Tilt PCB driver fault
-5 Motors PCB (3) driver fault
-5 Motors PCB (3) input voltage missing
-Internal Bus wiring connection fault