Revision 19.1
SOLO7 Transmitter User Guide
Copyright © 2013 Domo Tactical Communications (DTC) Limited. All rights reserved.
Commercial in Confidence
Page 5-17
5.4.2
Unit Settings
Name
Options
Notes
Operational State
Active
Standby
Sleep
Active
– The unit is fully powered and in an operational state.
Standby
– The unit is using less power but can be brought back
to operation rapidly.
Sleep
– The unit is consuming the least amount of power but
needs to be woken before being able to operate fully.
Disable status LEDs
Blue=Off
Orange=On
Swipe to the right to turn the status LEDs on the front panel
Off
.
ASI output
Blue=Off
Orange=On
Not applicable for SOL7TX.
ASI input
Off
On
Relay
When ASI input is
On
, this will add the service to the RF link.
Note
: You will have to divide the video bit rates so that they
don’t exceed the transmit mux bit rate.
In
Relay
mode, the remote service will be transmitted, turning
the local service off.
ASI Status
Information
Provides the current ASI status, if relevant.
Current ANC bitrate
Information
SDI cameras/sources may include ancillary metadata.