background image

BEDROOM

KITCHEN

BEDROOM

BEDROOM

LIVING ROOM

BEDROOM

SMOKE ALARM FOR MINIMUM PROTECTION

SMOKE ALARM FOR ADDITIONAL PROTECTION

SINGLE FLOOR PLAN

0.9M(3ft)

0.9M(3ft)

ANYWGERE
IN THIS AREA

HORIZONTAL DISTANCE

FROM PEAK

DIAGRAM 2

10CM(4”)

MINIMUM

1

0

C

M

(4

”)

M

IN

IM

U

M

3

0

.5

C

M

(1

2

”)

M

A

X

IM

U

M

CEILING

BEST HERE

NEVER HERE

ACCEPTABLE HERE

SIDE WALL

DIAGRAM 1

SPECIFICATION

The product is a new type of photoelectric smoke alarm, When 

it detects smoke twice, it will output signal immediately and 

trigger connected unit to work, which tell you in advance that 

fire will occurs and avoid unwanted loss, and take you safety 

and convenience.

Power supply:

 DC12V-DC24V

Static current 

(like following diagram):

Working current:

 16mA-17mA

Detecting time:

 detect once every about 5s

Detecting smoke method:

 it works only when it detects 

                                             smoke twice.

At first, you need install one item in every bedroom and route 

way at least.

Stairway is important for you to rush out when fires occur, so 

there must install smoke detector on the top of stairway.

You at least require one smoke alarm in every space of every 

floor, including finished attics and basements.

Install one alarm beside every electric facility.

You’d better Install smoke alarms in the middle of ceiling, 

because smoke always spread up;

If some reasons cause you can’t install them in the middle of 

ceiling, you also need to install them at least 10cm away from 

the wall.

If you like to install them on the wall, they should be installed 

10-30.5cm away under the ceiling. Diagram 1.

You need install more than one alarm when the length of your 

hall exceeds 9m.

In an oblique roof room, install the alarm 0.9m away from the 

top. Diagram 2.

How to install smoke alarms in a removable house. The 

removable house is short of heat isolation, so you'd better 

install the alarm 10-30.5cm away from the ceiling.

DSW928

Smoke Alarm Using Instruction

1. Where combustion are permitted to produce. For example 

unventilated kitchens, garages, and furnace;

2. near fanner;

3. In very damp, humid or steamy areas: Keep units at least 3m 

away from showers saunas, dishwashers, etc.

4. In very dusty, dirty, or greasy areas;

5. In very drafty areas, where smoke will be blown away from 

the unit completely,

6. in air-logged areas, that will clog the sensing chamber;

7. Less than 305mm away from fluorescent lights. Electrical 

“noise” can interfere with the sensor.

8. In “dead air” space, for example, in Diagram 1, near the 

corner less than 10cm.

9. in smoking meeting room, don't install the alarm there for the 

unit will alarm when several persons smoke.

50

55

60

0

24
18
12

Voltage(V/DC)

Static 
current 
(uA)

WHERE FIT TO INSTALL SMOKE ALARM

WHERE NOT FIT TO INSTALL SMOKE ALARM