DSPPA POE6401 User Manual Download Page 16

*                        *                                                         

                                                  Network Public Address System

 

Network Display terminal                                                                                                                           

POE6401 

11 

Performance specifications 

Indicator item 

Indicator 

AUX IN 

Input sensitivity 

1000

 mV

 

Frequency response 

20Hz-20kHz 

Distortion 

0.1% 

Noise 

1

mV

 

Signal-to-noise ratio 

80

 dB

 

AUX OUT 

Output sensitivity 

1000m

V

 

Frequency response 

2Hz-26kHz 

Distortion 

0.05% 

Noise 

0.12

 mV

 

Signal-to-noise ratio 

77

 dB

 

Maximum output power of 

the 

built-in 

power 

amplifier 

Independent channel mode  10W/4Ω 

Maximum  harmonic  distortion  of  the  built-in  power 

amplifier 

0.3% 

MIC microphone input 

Input sensitivity 

10

 mV

 

Frequency response 

20Hz-20kHz 

Distortion 

0.5% 

Noise 

2

 mV

 

Signal-to-noise ratio 

75

 dB

 

USB/SD 

/NET 

Play MP3 

Output sensitivity 

7.8

V

 

Frequency response 

10Hz-20kHz 

Distortion 

0.05% 

Noise 

1

 mV

 

Signal-to-noise ratio 

80

dB

 

Capacity of external U disk supported 

32GB 

Range of power supply voltage 

45-256V/50Hz 

OVERCURRENT, 

overheat, 

over-voltage 

and 

under-voltage protection 

Conforming to 

Package size (L×W×H mm) 

270×210×110 

Machine size (L×W×H mm) 

190×195×50 

Net weight 

1.45kg 

 

 

 

 

 

 

Summary of Contents for POE6401

Page 1: ...L STBY Net Service Timing Signal P L A Y Network Terminal POE6401 User Manual Thank you for using our DSPPA public address system Please read this User Manual carefully to make better use of this equi...

Page 2: ...nical indicators of the product and other contents of the four way network public address terminal Prior to connection installation and use the user shall carefully read the instructions and conduct o...

Page 3: ...th the power grid The power cord plug shall be unplugged from the power socket for safety when the equipment is not used Laying position Please disconnect the power supply prior to movement of the equ...

Page 4: ...nt electric shock Please do not try to disassemble internal parts of the equipment or conduct transformation of any form In case of any anomaly please immediately stop use and invite the professionals...

Page 5: ...ternal appearance 2 2 1 Introduction of the front panel 2 2 2 Introduction of the side panel 3 2 3 Instructions for remote controller structure 4 III Connection legend 6 3 1 Schematic diagram of appli...

Page 6: ...wer amplifiers so as to expand the power there is a way microphone interface so as to realize local paging and so on 1 2 Performance features It can work across the network segments It can be coupled...

Page 7: ...successfully connected through the network the indicator lamp is on 4 Timing The terminal can be separated from the host machine to implement the timing point edited When the terminal can be separated...

Page 8: ...the viewed parameters Set IP mode parameter plus minus function 14 VOL key Play mode volume up function View IP mode switch and select the viewed parameters Set IP mode parameter plus minus function 2...

Page 9: ...the terminal power 11 MIC2 interface Connect the microphone to realize local paging site talking and other functions Not opened to the machine 12 Power amplifier cooling window 13 Power POWER Press I...

Page 10: ...the terminal 11 F3 IP address view modification key Press it to enter view state press CH CH to select the parameter to the view press F3 to enter the setting state and press Enter for saving after mo...

Page 11: ...he machine a way auxiliary input and a way auxiliary output are also arranged to connect other audio sources and power amplifiers The customized design can satisfy demands for high power and multiple...

Page 12: ...e connection of the machine is shown in the following figure The power amplifier is 2 10W output note please adopt two way simultaneous output with caution due to POE switch supply power restrictions...

Page 13: ...switches to display the corresponding parameter value c At the moment press Set key to enter IP address modification state When the parameter flashes press key or key to switch the parameter bit press...

Page 14: ...not place any corrosive chemical near or on the equipment 2 Precautions for after sales service Our company will offer three year free warranty including provision and replacement of parts for free f...

Page 15: ...k display terminal 1 set 2 1500MM dual modem audio cable 1 piece 3 3000MM 8 core network cable 1 piece 4 Instructions 1 copy 5 Guarantee card 1 copy 6 Conformity certificate 1 copy 7 7P green plug 3 8...

Page 16: ...fier Independent channel mode 10W 4 Maximum harmonic distortion of the built in power amplifier 0 3 MIC microphone input Input sensitivity 10 mV Frequency response 20Hz 20kHz Distortion 0 5 Noise 2 mV...

Page 17: ...plate at discretion so as to prevent electric shock The professional with professional certificate shall conduct repair if necessary The terminal marked with symbol in the equipment represents hazard...

Reviews: