Explanation  on priority of channels to call standby amplifier under the mode of 4 mains and  multiple standbys: 

each channel has no priority in the automatic call mode and follows the principle of "first call, first use". When the 

four channels CH1 -- CH4 automatically call the standby power amplifier, the standby power amplifier AMP5 is 

with the priority among the five standby power amplifiers (AMP5 -- AMP9). If AMP5 has been called or is in an 

abnormal status, the next priority is AMP6. And so on, the final AMP9. So the priority of these 5 standby power 

amplifiers is from AMP5 to AMP9. 

 

 

 

 

(6)

 

Zone load settings 

 

Click the "zone load setting" button on the zone setting interface as shown in Figure 3-22, and the window of 

"zone  load  setting"  as  shown  in  Figure  3-23  will  pop  up.  Click  the  icon 

  or 

  to  set  the  alarm 

threshold of zone load by 5% or 95%. When the load becomes lighter and the actual display value is less than 

the set threshold, the load status bar in the main interface will display open circuit. 

 

 

Figure 3-22 Zone setting interface 

 

 

If one channel is not connected to zone load before starting up and is connected to the load after starting up, 

the user needs to enter the zone setting interface and click the 

  button after “zone load initialization” to 

complete the initialization setting. Click “exit and save”, the setting is successful. 

Summary of Contents for PC1021X

Page 1: ...10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A STATE SIG STATE SIG STATE SIG STATE SIG STATE SIG STATE SIG STATE SIG STATE User s Manual Welcome t...

Page 2: ...nstructions and other contents of the 8 Channel Amplifier Matrix Controller PC1021X device The user shall read the Instructions carefully and operate the device following the indications in the Instru...

Page 3: ...the device Do not impose an excessive force when operating the switch buttons or connecting the external audio equipment Avoid any foreign matter paper metal etc from entering the device through gap...

Page 4: ...UP 5 4 2 MAIN INTERFACE INSTRUCTIONS 5 4 3 INTERFACE OPERATION INSTRUCTIONS 7 1 SYSTEM SETTINGS 7 2 EQUALIZER AND MASTER VOLUME SETTINGS 8 3 AUDIO OUTPUT LEVEL SETTINGS 9 4 MONITORING ON OFF AND VOLUM...

Page 5: ...rt hot plug for the power switching modules can plug the power switching modules with electricity on after switching off all the zones on the interface without powering off the device With real time p...

Page 6: ...A STATE 2 4 6 8 10 SIG PCX 5A STATE 1 5 band output level indicator The indicator shows the volume of output dynamically 2 Screws for switching main and standby power modules Loosing the screws manual...

Page 7: ...OT OPEN OUT OUT OUT OUT OUT OUT OUT OUT SEC PRI Nur Sicherung 250V Use Only With A 250V Fuse Employer Unlquement Avec Fusible De 250V 1 3 4 6 2 5 7 LINK IN LINK OUT 1 Dante interface optional With CAT...

Page 8: ...SK OF ELECTRIC SHOCK DO NOT OPEN IN IN IN IN IN IN IN IN Audio input PC1021X 8 channel amplifier matrix controller DA8250 digital amplifier AMP INPUT SPEAKER OUTPUT OUT GND CH9 CH8 CH7 CH6 CH5 CH4 CH3...

Page 9: ...2 Main interface instructions The display will show the main interface automatically the factory setting is 8 main and 1 standby amplifier modes As figure 2 1 shown the status of 8 zones figure 2 1 sh...

Page 10: ...determine the load state If the zone is in open state 1 if the audio input signal of the channel disappears 10s the channel will begin self check to test the load state The channel will be closed aut...

Page 11: ...e CH1 zone status bar Figure 3 1 CH1 zone setting interface The following operations can be conducted in CH1 setting interface 1 System settings 1 Working mode settings Click the icon in the zone sett...

Page 12: ...ice life of the screen the setting range of fixed backlight time is 30s 240s Figure 3 2 System setting interface 2 Equalizer and master volume settings In the zone setting interface shown in Figure 3...

Page 13: ...wn box will appear Click and select one of them according to requirements Figure 3 5 Zone setting interface 4 Monitoring ON OFF and volume settings Slide the monitoring slide to ON status the system d...

Page 14: ...g interface as shown in Figure 3 7 and the channel main and standby switch interface as shown in Figure 3 8 pops up Click the yes button to turn on the current channel main and standby switch If you w...

Page 15: ...wer amplifier of the current channel returns to normal the system will automatically restore the main power amplifier If the current channel master standby switch is OFF the channel is no longer with...

Page 16: ...gain the window of manual call setting pops up as shown in Figure 3 12 the function of manual adjustment will be turned off by clicking the ok button Click yes to switch off the manually call function...

Page 17: ...current amplifier is a standby amplifier and it is free currently Green icon means the current amplifier is working normally Gary icon means the current amplifier is now with no amplifier Red icon mea...

Page 18: ...ifier can be called Priority of channels to call standby amplifier CH1 AMP1 AMP9 High Low CH2 AMP2 AMP9 CH3 AMP3 AMP9 CH4 AMP4 AMP9 CH5 AMP5 AMP9 CH6 AMP6 AMP9 CH7 AMP7 AMP9 CH8 AMP8 AMP9 Table 3 1 Ex...

Page 19: ...mplifiers As the main interface shown in the Figure 3 16 Channel CH1 CH4 are four working zones and the standby power amplifier of each channel is AMP 9 see Table 3 2 for details Now the zone setting...

Page 20: ...longer has main and standby switching function c When the device is under 4 mains and 4 standbys working mode there are 8 default external power amplifiers As the main interface shown in the Figure 3...

Page 21: ...lifiers As the main interface shown in the Figure 3 20 Channel CH1 CH4 are four working zones and the standby power amplifier of each channel see Table 3 4 for details Now the zone setting interface i...

Page 22: ...ower amplifiers is from AMP5 to AMP9 6 Zone load settings Click the zone load setting button on the zone setting interface as shown in Figure 3 22 and the window of zone load setting as shown in Figur...

Page 23: ...ss the buzzer is on for 1 second 3 Enter the calibration mode and click the specified position of the touch screen to calibrate the touch screen according to the cross line 4 Return to the screen afte...

Page 24: ...g any connection Do not open the case to repair the device without authorization in case of any fault in order to avoid the accident or aggravate the damage of the device Do not put any corrosive chem...

Page 25: ...st Quantity 1 User s manual 1 copy 2 Warranty card 1 copy 3 Certificate 1 copy 4 10A MP P power cord 1 set 5 2P green plug 17 pieces 6 2P plug lug terminal 7 62MM 17 pieces 7 Washer black 4 pieces 8 5...

Page 26: ...the cover of the machine to prevent the electric shock If necessary it shall be repaired by the professional with the professional certificate The terminal marked with a symbol in the device indicates...

Reviews: