background image

 

* Public Address System                                                                                                Intelligent Public Address System 

 

18 

considered  as  a  sound  source  distribution.  So,  before  opening  or  closing  the  partitions,  you  should 

bounce all sound source buttons 

So  far,  the  partition  operation  has  been  completed.  If  necessary,  you  can  continue  the  following 

operations, to perform 

partition setting.

 

4

5.5

 

Click “

system setting

” button to enter the system setting interface, and then click “

partition setting

” 

button to enter the partition setting interface. 

4

5.6

 

Within  the partition  setting  interface, the current partition schemes (sound  source  distribution, on-off 

state of partitions) can be saved.  For this purpose, you can click “

save partition

” button to enter the 

save partition interface. The interface will display five save buttons, showing that there are 5 addresses 

available for saving. If the button bracket displays “empty”, it means that the address content is empty, 

otherwise meaning that a predetermined scheme is saved in the address (the save date of this scheme is 

also labeled).  Click any save button and  click “

confirm

” button, then you can save the scheme, and 

return  back to the 

partition setting 

interface. If  the clicked button is  not empty, the original content 

will be replaced by a new scheme after clicking “

confirm

”; and if click “

empty

”, the content will be 

removed. 

4

5.7

 

Click the  “rename”  button on the  “partition  setting”  interface to enter  the partition  rename interface. 

Select  the  partition  number  to  be  modified  in  the  list  under  “

partition  selection

”, then  the  partition 

number  that  you  want  to  modify  will  be  displayed  at  the  right  side  of  the  “

partition  number  to  be 

modified

”. Click the character under “

partition  naming  character  selection

”, then you can add the 

corresponding character to the textbox at the right side of the “

new partition name

” (Note: if you do 

not select the partition number to be modified before, then the selected character will not be added to 

the  “

new  partition  name

”),  which  can  consist  of  9  unit  characters  at  most.  Note  that,  a  Chinese 

character  is  two  unit  characters.  If  it  is  input  incorrectly,  you  can  click  “

back

”  button  to  delete  the 

character that you just input, and after the new partition name is selected, please click “

change

” button, 

then the partition name is changed. 

4

6

 

Timing setting 

The timing sequence is used to manage the work and rest time of the system. A thousand time points can be set a 

day; and at each time point, 4 AC power supply channels on the back panel of the host can be opened and closed 

independently, and hourly chime can be published, and also, DSPPA programs and inner CD programs need to 

play can be set. As the above 4 AC powers usually supply power to the partition amplifiers and other peripheral 

devices, so the power program timing sequence controls the whole system’s operation. 

The power program timing sequence can be established by week. 

4

6.1

 

First establish a timetable according to the work and rest time, considering the system configuration. 

We assume that the timing power channel  1  supplies power to the partition amplifiers;  channel  2  to the 

external  CD  players,  tuners,  cassettes,  and  these  external  sound  sources  prepare  to  provide  optional 

background music for the office building; and channel 3 and 4 are for standby use. 

Then we assume that the time arrangement of the organization from Monday to Friday is: 

8

00    on duty;    12

00    off duty;        14

00    on duty;        16

00 off duty. 

Accordingly, the recommended timetable for the system operation is as follows (for a workday): 

 

 

 

 

 

Summary of Contents for MAG2189

Page 1: ...C MIC Public Address Multimedia Matrix OFF ON MAG 2189 TOUCH PAD FULL ALARMING USB User s Guide Welcome to use the DSPPA public address system Please read this manual carefully before using this device for your better use Guangzhou DSPPA Audio Co Ltd http www DSPPA com http www dsppatech com ...

Page 2: ...struction product use instruction product specification and so on Please read this manual carefully before installation and use of the device Follow the instructions in the manual All instructions with this mark on the back panel of the machine are matters needing attention Be sure to use or operate the device according to these instructions Please keep the Specification properly for unexpected ne...

Page 3: ...re of typical system 13 3 2 Connection of typical system 13 3 3 Running of typical system 14 IV System setting 16 4 1 System time setting 16 4 2 Resource status checking 16 4 3 Comprehensive setting 17 4 4 Sound source setting 17 4 5 Partition operation and setting 17 4 6 Timing setting 18 4 7 Default programs editing 20 4 8 Alarm setting 20 4 9 Language selection 21 4 10 Paging setting 21 4 11 Ph...

Page 4: ...am sources can be built in according to user needs such as etiquette gymnastics tracks various bells alarm whistles and guest greeting seeing guests off warnings and other broadcasting audio files City call interface is available and calls can be answered or rejected automatically Convenient for a telephone remote control or holding a teleconference 1 48 remote control partition paging channels Fi...

Page 5: ...h screen display various information of the machine in real time directly touch the screen to operate the function items Prompt USB interface can externally connect the mouse to operate the device Pin 2 of the EMC MIC is connected to the signal port and pin 1 and 3 are grounded 4 Built in compact disk driver of CD player Press the in and out key to open the disk driver and put the CD disk in the d...

Page 6: ...AINS TEST DATA SCRN CH 1 TIMING OUTLET 220V 50Hz 8A CH 2 CH 3 CH 4 请勿打开 以免触电 RISK OF ELECTRIC SHOCK DO NOT OPEN 警告 CAUTION 智能广播媒体矩阵 广州市迪士普音响科技有限公司 Guangzhou DSPPA Audio Co Ltd Nur Sicherung 250V Use Only With A 250V Fuse Employer Unlquement Avec Fusible De 250V Normal Input Module III LINE1 LINE2 LINE3 LINE4 LINE5 LINE6 LINE7 LINE8 Normal Output Module III CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 Prior Input...

Page 7: ...e fire control center and can be programmed and compatible with high low alarm level optional 0 16 Break in control module MAG2832 16 lines of break in control signal output used for activating alarms paging and call break in area optional 0 16 Monitor module MAG2818 An indispensable module of the system Automatically manually monitor signals output from sound sources or partitions 1 Remote call m...

Page 8: ...in interface of the screen When pressing the prior sound source button you can operate the prior input module correspondingly such as partition allocation and volume adjustment After the system receives the fire control disaster alarms it will forcibly allocate the prior sound source to partitions where alarms need to be given and the selected adjacent regions Please refer to descriptions of item ...

Page 9: ...the screen default If there are more than 8 partitions in the user s system several partition output modules shall be used One partition output module shall be added for every 8 partitions increase The partition number to which each output module corresponds is determined by the distributor through hardware setting of the module At most 250 partitions can be set requiring 33 partition output modul...

Page 10: ...by use and the drive capability is also 100V 1A Generally the optional quantity of break in control modules in the system should be the same as that of the alarm input modules and their serial numbers are also determined by the distributor through hardware setting 1 3 6 Monitor Module MAG2818 The module is used to monitor each link of the system and the specific monitoring points are operated by t...

Page 11: ...fier and then several amplifiers or other devices can be connected like this Click the periphery control button of the smart host the addresses names and working conditions of all online peripherals will be listed If a fault occurs fault phenomenon can also be displayed If operation of the peripherals is needed such as giving an alarm artificially you can select the peripheral to be operated first...

Page 12: ...outlet is exactly the transform interface of emergency microphone of the front panel The priority of 4 built in sound sources is EMC MIC CHIME ALARM INNER CD DSPPA SOURCE As an example 8 speaker areas are arranged for this minimum system which share 1 amplifier 2 4 Running of minimum system 2 4 1 After confirming that the line is connected well start the power of the device with a special switch k...

Page 13: ...o publish a paging broadcast take down the emergency microphone press the switch on the microphone then you can start to call other programs will be mute automatically If necessary you can click CHIME button before paging to publish the prompt chime When it is necessary to temporarily close start some partition speakers only need to click the corresponding partitions buttons When it is necessary t...

Page 14: ...al button at the lower left corner will flash reminding users that the system has already separated from program control If you need to recover the program control function you can click the program control button making it not flash again and turn to gate state bright color 2 4 6 When you need to publish a disastrous alarm you can forcibly press the full alarm button at the upper right corner of ...

Page 15: ...e the prior microphone or insert the external sound sources into the vacant inlet of the prior input module temporarily to support the system operation the priority needs to be noted at the same time full alarm manual button is still effective 2 5 Restrictions of minimum system The minimum system has already possessed basic functions of a public broadcast but it does not have fire control telephon...

Page 16: ...ons Other normal input ports can be used by any external sound sources For example to provide several leisure programs to guest rooms if any in the broadcast service area several CD players or tuners can be connected externally Additionally arrange a meeting room as a speaker partition and distribute a standby input port to it pre embed lines in the field When necessary externally connect the soun...

Page 17: ...ding to the programs preprogrammed by the user chime will played punctually and automatically at program control timing points and the corresponding power channel will be opened or closed automatically on time And also the system will correspond to the telephone remote call alarm partition breaking in 3 3 3 Alarm signals from the fire control center will start the first class prior partition break...

Page 18: ... partitions then you can play the DSPPA sound source or inner CD immediately in those partitions When necessary you can enter the system setting to select needed programs You can click chime button to publish chime to all currently gated partitions When necessary you can enter the system setting to select needed chimes When performing the above manual interventions the control program is still run...

Page 19: ... touch the screen or touch the touch pad then the screen display can be recovered If not using it for a long time you should completely power it off When powering it off you should not easily and directly use the key switch to turn off the power instead you should first click the system setting button entering the system setting interface and then click the close the system button and after the sc...

Page 20: ...prehensive setting and please see 4 14 for the operations of play interface if the clicked one is the external sound sources then you need to operate and control the sound source device to let it play sound When use automatic monitoring mode is checked in the comprehensive setting see 4 3 then the sound of this sound source can be heard through the monitor speaker 4 5 2 Then click the partition bu...

Page 21: ...racter under partition naming character selection then you can add the corresponding character to the textbox at the right side of the new partition name Note if you do not select the partition number to be modified before then the selected character will not be added to the new partition name which can consist of 9 unit characters at most Note that a Chinese character is two unit characters If it...

Page 22: ...cted at the current time point in the selection box of power channel at the lower middle of the screen then click the right end of the prompt tone box at the lower right of the screen and pull out the prompt tone hourly chime list then click the needed prompt tone including mute When clicking a prompt tone the monitor speaker will give out this tone for reference if it is not suitable you can clic...

Page 23: ...ogram that you want and then click copy button then the selected contents will be added to the selection area If there are programs that you do not want in the selection area you can click delete button under the program operation 4 8 Alarm setting When the alarm input module receives a fire control disastrous alarm the system will forcibly distribute the prior sound source to the partitions needi...

Page 24: ...om the center including in the machine room provided to the on duty person specially for partition paging The paging setting is used to set the volume of each remote paging channel 4 10 3 Click paging setting to enter the setting interface and drag the 4 volume adjusting sliders then you can adjust the volume of the 4 remote paging channels which should cooperate with the volume adjustment of the ...

Page 25: ...in DSPPA or CD audio source pop up program player window in the integrated settings then directly click on the DSPPA or CD audio button to pop up the corresponding program playing window 4 14 2 The program box is on the right side of the program play window which lists the names of programs built into the system Click or drag the vertical scroll bar on the right side of the program box to see more...

Page 26: ...ressing the emergency microphone on the front panel of the host Click the Start Recording button to start recording the program Click the Stop Recording button to stop recording and automatically or manually save the program recorded in the system and the program name program length and recording time appear in the system library At this time click Start Listening to listen to the recorded program...

Page 27: ...P switch of the function module The factory will not be responsible for any damage or malfunction caused therefrom If you have any problems please contact the supplier to solve them All built in or accompanied function modules of this machine must be strictly coded before delivery which are only applicable to this machine and unable to be used in other PMM machines If it is required to be replaced...

Page 28: ... 10 4 inches Control mode Touchpad touch screen Working environment Ambient temperature 5 35oC relative humidity 75 air pressure 86 106kPa Timing power with load capacity Single channel current 2A 4 channel total current 5A System audio signal SNR A weighted 90dB System audio signal distortion 0 1 1kHz System audio signal input level range 1Vrms 2Vrms 4Vrms optional System audio signal input imped...

Page 29: ...wer supply For the sake of safety unplug the power cord from the outlet when it is not in use This device can not be subjected to water droplets or splashes and items such as vases filled with water can not be placed on the device Do not open the cover of the machine to avoid electric shock If necessary professionals with the certificates can repair it Guangzhou DSPPAAudio Co Ltd ...

Reviews: