6. Description of Remote Controller Keypad 

 

 
 
 
 
 
 
7. Operating Instructions

 

           

The  phased-array  column  speaker  is  operated  by  infrared  remote  controller.  The  operation  of 

remote controller is effective when it operates within 18

0

°

in front of the sound column.

 

 

 

 

1. Switch on the unit   

 

 

 

 

 

      (Firstly,  the 

UDE

  will  appear  before  entering  this 

interface).   

 

 

2.

 

Adjust the volume 

Press 

V+

 or 

V-

  

 (Max. volume: 32 levels; Min. volume: 

0). 

 

 

 

3.  Equalization Adjustment 

Press 

EQ

                                                  (Range of adjustable frequency: 80Hz-20kHz) 

 
 

Press 

V+ or V-

 to move left and right for selection of frequency band (14 bands in total). 

 

        Press 

AN+  or  AN-

  to  adjust  the  amplitude  of  selected  frequency  band  (Adjustable  amplitude: 

Infrared remote controller

 

1.  Mute key 
2.  Sensitivity selection key (Sensitivity) 
3.  Volume setting key (V+) for increase and (V-) 

for decrease 

4.  Directivity  setting  key  (AN+)  for  increase  and 

(AN-) for decrease 

5.  Shift key for equalization setting (EQ) 
6.  Focus adjustment key (FOCUS+, -) 
7.  Treble adjustment key (, -) 
8.  Bass adjustment key (BASS+, -) 

9.

  On/OFF key (Note: The ON/OFF key can only 

switch off the current play status, but it cannot 
switch  off  the  main  power  of  the  column 
speaker).  To  switch  off  the  power  supply, 
please  remove  the  power  plug  from  the 
socket).

 

 

Startup Interface

 

Volume Interface

 

EQ Interface

 

Summary of Contents for DSP1501

Page 1: ...Public Address Device DSP1501 Phased Array Column Speaker Operation Manual Welcome to use our Public Address System For better use of this equipment please read this manual carefully before use...

Page 2: ...Column Speaker 1 1 Product Description 2 2 Functions 2 3 Description of Remote Controller Keypad 2 4 Installation Diagram 3 5 Description of Back Ports 3 6 Description of Remote Controller Keypad 4 7...

Page 3: ...ublic Address System Operating Instructions 1 The subassemblies of Phased array Column Speaker Infrared remote controller Speaker fixing screws x 2 RCA connector XLR connector male XLR connector femal...

Page 4: ...omplicates shapes l Active column speaker with built in digital signal processor and digital power amplifier so that it is no need for driving of external power amplifier l This unit has AUX signal in...

Page 5: ...Connect the wire correctly as described in Section 5 Check if the column speaker is secure and confirm that the connection is correct Then plug the power cable of column speaker into AC socket 5 Desc...

Page 6: ...left and right for selection of frequency band 14 bands in total Press AN or AN to adjust the amplitude of selected frequency band Adjustable amplitude Infrared remote controller 1 Mute key 2 Sensiti...

Page 7: ...ess again 7 Select Input Sensitivity Value Press S Hold down S again With S key held down the three sensitivity values i e 00dBV 06dBV and 10dBV will be displayed alternatively When the desired sensit...

Page 8: ...en saver status you may press any key from remote controller to enter into associated operating interface 8 Specifications Model DSP1501 Rated power 100W Input sensitivity 00dBV 06dBV 10dBV 70 100V Ra...

Reviews: