Delta Frequency
Half width of the transition region.
Unit: Hz
Range: 0 Hz .. 234 Hz in steps of 23 Hz
LFE -10dB attenuator (Dolby/DTS)
Activates a 10 dB attenuation at the LFE output.
Extra Sub to LFE
The fader „Extra Sub to LFE“ controls the amount of additional bass, which
is extracted from the stereo reference signal and which is mixed to the LFE
channel of the output bus.
Unit: dB
Range: 0 dB..-inf
Please note:
See
Appendix B: Schematic Block Diagram
Extra Sub to LFE Mute & Fade
Mute deactivates the extra bass. Solo mutes all other mute / solo controls.
This is useful to monitor the complete signal without the extra bass.
HCF Window
The HCF window features a high frequency attenuator on the rear channels
that allows the user to polarize the image and
reinforce the attraction of the front channels.
Just like "SUB", this filter acts on the spectral
envelope with a gain in amplitude and constant
phase. This filter applies to the internal bus at
the end of the Panoramic Analyzer and Virtual
Microphone.
Options:
Cut Frequency (0 Hz – 20 kHz)
Delta Frequency (0 Hz – 20 kHz)
Attenuation level (0 dB - -inf)